ACOEM Sweden has assisted industries worldwide in achieving profitable and sustainable production since its inception in 1984. The company has gained its current position by daring to think beyond conventional norms and following unconventional paths. ACOEM Sweden has also shown the courage to make mistakes and discover new avenues. Through their determination, ambition, and expertise, they have emerged as a global player and a pioneer in innovative and user-friendly shaft alignment.
Could you pls clear my doubt's? 1#Minimum Fixing distance? 2#Which is we want to set first? H or V 3#Once complete alignment the readings all correct but while checking again that all reading was changed. What is the reason, why and how to correct? 4# Where should Fix the Leaser Fixer (Chain clamp ), Coupling or Shaft 5#How to do Alignment coupled conditions or Decoupled Conditions (What is the reason?) 6#Some time one angle is shown in down side, Is this problem or not problem? How to set both Angle reading in Top side?
Used one today to align first stage axial compressor (15 tons) to second stage (8 tons) makes it a lot easier on yourself limiting the number of times you have to make shim changes. 2nd to motor Monday after large bore piping installed and no pipe strain affecting the compressors, never align to the piping.... you pipe to the pump!
Не правильно нахлобучил датчики на стойки , что и сказалось на S t позиции ! Не спеца сразу видно по мелочам ! В любой работе голова идет на шаг впереди , чем руки !
I am interested in knowing how to measure flatness of a rectangular metallic mounting pad (for turbine) LxW (1meter x 0.4 meter) and flatness specified by turbine manufacturer is within 0.030”/ft (2.5 mm /meter) and coplanar to 0.120” (3.0 mm) to the other pads.