Тёмный
Rain Brothers LLC
Rain Brothers LLC
Rain Brothers LLC
Подписаться
All about rainwater harvesting. We at Rain Brothers, LLC specialize in installing rainwater harvesting systems of all sizes (commercial, industrial, and residential), as well as selling products related to rainwater capture and reuse. Here, we will share our knowledge and years of field experience to help our viewers design and construct a professional-grade system.

Please visit our website: www.rainbrothers.com
For questions, please do not hesitate to contact us!

Thanks for watching
How to install a cistern liner
10:33
Месяц назад
Plumbing a concrete cistern water tank
10:22
3 месяца назад
INCREDIBLE! Rain harvesting pre-filter
1:01
6 месяцев назад
Rain harvesting trick! Free extra water!
1:51
7 месяцев назад
Automatic Pump Controller
9:29
9 месяцев назад
Underground poly cistern installation
9:59
11 месяцев назад
How to fix a low-yield water well
11:24
Год назад
RainRouter Rain Barrel Diverter
3:00
Год назад
Комментарии
@WILLYDOGUSA
@WILLYDOGUSA 7 часов назад
Pretty clear video, only one question, if the system is 220v then the neutrals (white wires) coming from the pump and the electric panel are just going to connect directly with a wire connector?
@rainbrothers
@rainbrothers 6 часов назад
220v pumps don’t have a neutral leg. Only two hots and a ground, and both hots get wired into the switch.
@JohnSmith-fi2gu
@JohnSmith-fi2gu День назад
Are you using the pump saver to protect the well pump from running dry when filling the storage tank? I am adding 400 gallon storage in basement and already have a pump saver just know my well wont fill sa6 100 gallons of used water from my storage tank
@rainbrothers
@rainbrothers 22 часа назад
Hi - thanks for writing. Yes, the PumpSaver is used to protect the well pump from running dry. There was a type-o in the second part of your question so I’m not quite sure what you meant
@creativel.e.2436
@creativel.e.2436 3 дня назад
Thank you.
@Steelerfan963
@Steelerfan963 3 дня назад
Could you say how the pump power is provided to pump out the water?
@rainbrothers
@rainbrothers День назад
Hi - thanks for the question! We have more videos that go into detail on this point. Here is one that might help answer your question: Installing pump in rain harvest cistern ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-2B4wJKUWVzs.html
@WVhillDweller
@WVhillDweller 3 дня назад
How do you feed a rain water tank into a house that already has an existing well? The well is already running into the house with a pressure tank and switch.
@rainbrothers
@rainbrothers День назад
You can do it a few different ways, but the best way is to use a second pressure tank and tie the two water supplies together (downstream of filtration) and use a series of valves to open one up and close off the other. I would highly recommend incorporating check valves when doing this so the two water systems don’t contaminate each other
@todstrucks2919
@todstrucks2919 10 дней назад
I have a question,on your pump installation video using 1” PVC schedule 40 you used a 1 3/4” hole saw. For the vent 2” PVC I’m assuming you use 2 3/4” hole saw? I’m installing my cistern and pump tomorrow, using 1” poly & 2 frost free hydrants. I Purchased, a pump, a vent cap, 2 1” rubber, grommets, and 1 - 2” rubber grommet. Your videos definitely make it look easy. Thanks 4 the video Super helpful
@rainbrothers
@rainbrothers 9 дней назад
For the 2” gasket, you’ll actually drill a 3” hole. Here is the hole saw size chart for our gaskets: drive.google.com/file/d/1jBcaXIhM8bbcwE48z4LzQyspuHlyGbLT/view If that link doesn’t work, there’s also a link on the product page for the Tank Penetration Gaskets on our website. Thanks so much for your business and for the kind words! Feel free to call or text our shop tomorrow if any part of the install needs clarification
@todstrucks2919
@todstrucks2919 9 дней назад
@@rainbrothers thank you for the answer. I actually called your office first thing this morning. The person who answered the phone was very helpful. I actually had a couple of questions, and she answered them perfectly. I wasn’t looking at the chart right. A little intimidated on drilling the hole in the tank.
@StephanieDharmaHill
@StephanieDharmaHill 10 дней назад
This demonstration is very well put together. GREAT work. Thank you for taking the time to explain how a top notch underground rain harvest system is installed.
@rainbrothers
@rainbrothers 9 дней назад
Thanks so much for the kind words!
@rainbrothers
@rainbrothers 12 дней назад
Hey y’all - I should’ve clarified. This is for rainwater leaders (drainage from downspouts)- this is NOT a fix for sanitary/sewer plumbing. Clean water travels thru these pipes - not sewage.
@beauskelton7819
@beauskelton7819 12 дней назад
Basically what not to do lol
@rainbrothers
@rainbrothers 12 дней назад
This is drainage - not sanitary plumbing
@bigandfatty1
@bigandfatty1 12 дней назад
Fernco is for joining of two dissimilar types of material only
@ronjeremy-s3h
@ronjeremy-s3h 12 дней назад
You could have used slip couplings😊
@rainbrothers
@rainbrothers 12 дней назад
Personally, I struggle with slip couplings. I much prefer Ferncos. But, as they say, there’s more than one way to skin a cat. Thanks for the suggestion!
@ronjeremy-s3h
@ronjeremy-s3h 12 дней назад
@@rainbrothers slip couplings are specifically almost a 1/8" larger so it can fit over the pipe I've worked with several slip couplings over the years they're convenient but they're expensive also you got to use Clear primer not purple purple makes it stick too much and makes it harder to work with
@rainbrothers
@rainbrothers 12 дней назад
@@ronjeremy-s3h Oh yes - I’ve worked with slip couplings a handful of times, but in cases like this where I need to rotate the pipe after installing the tee, it saves a step or two to use Ferncos. Thanks for commenting! Have a good one
@iainpoteet5760
@iainpoteet5760 12 дней назад
Just why🤦🏼‍♂️
@rainbrothers
@rainbrothers 12 дней назад
This is downspout drainage, not sanitary plumbing
@TheHtownplumber
@TheHtownplumber 12 дней назад
You can’t use a San Tee on its side as a drainage fitting . And CT couplings aren’t allowed . Buy a Combo and Husky Bands
@rainbrothers
@rainbrothers 12 дней назад
These are not sanitary lines - this is rooftop drainage that has already been filtered, so it’s clean water. Sorry, that was not clear, but for those who follow my channel, they would know that
@miltongenovez4315
@miltongenovez4315 12 дней назад
Tees don’t go laying down, plus you need sheer-bands
@rainbrothers
@rainbrothers 12 дней назад
This is downspout drainage - not sewage. That is not clear from my video, so I apologize for the confusion. For those who follow my channel, they know that we don’t do sanitary plumbing. Thanks for the feedback
@grandmasteryoda2471
@grandmasteryoda2471 12 дней назад
Need a shear band coupling.
@rainbrothers
@rainbrothers 12 дней назад
Great feedback! This is not sanitary plumbing, though - it’s downspout drainage and clean water is passing thru. Straight Ferncos have been used by drainage contractors for decades, but I do like the idea of incorporating sheer bands in some applications.
@kristiankirkland8283
@kristiankirkland8283 12 дней назад
So those clamps won’t rust.?
@Chef70221
@Chef70221 12 дней назад
Built for a 50-year service
@rainbrothers
@rainbrothers 12 дней назад
They are stainless steel
@TheIggypop1
@TheIggypop1 12 дней назад
Use couplers not ferncos
@Chef70221
@Chef70221 12 дней назад
these couplings are designed to be buried
@rainbrothers
@rainbrothers 12 дней назад
Yes, and this is downspout drainage, not sanitary plumbing for those who didn’t catch that
@rikii7237
@rikii7237 12 дней назад
no
@rainbrothers
@rainbrothers 12 дней назад
This is not sanitary plumbing - it’s downspout drainage. That was not apparent when I published it, so I apologize for the confusion
@rikii7237
@rikii7237 12 дней назад
@@rainbrothers and now my no turns into a yes ✅
@load_nikon6435
@load_nikon6435 14 дней назад
I have one of those and found it clogs with fine sediment and debris gets caught where the downspout meets the screen. Do you carry Rain Harvesting's Leaf Eater filters?
@rainbrothers
@rainbrothers 14 дней назад
There are undoubtedly issues with all types of filters, because they will all clog and require cleaning eventually. The nice thing about this is: 1) It’s price point; 2) It’s made in the USA; and 3) It’s not made of plastic, so it will last longer and weather better. We have tried Rain Harvesting’s “rain heads” in the past (Leaf Eater being one model), and have found that they work about as well as this one but they are not as durable since they’re made of plastic, they have an open front (which, once they clog, will channel water straight out, missing the downspout/cistern completely), and they’re made in Australia so they’re more expensive. Our first recommendation for excellent pre-filtration is our Monjolin filters, followed by our Wisy vortex filters… but those are expensive, and for older cisterns, these are easy to add on and they do the job of keeping coarse debris out. Thanks for writing!
@load_nikon6435
@load_nikon6435 13 дней назад
@@rainbrothers Concur, affordable, not plastic, and domestically made are highest priorities. Thanks for the reply and thank you for publishing the video!
@rainbrothers
@rainbrothers 12 дней назад
@@load_nikon6435 Thank you for your feedback! I always am curious to know folks’ experience with various products, and really appreciate you taking the time to comment and share
@johnathankeller1948
@johnathankeller1948 17 дней назад
Wonder if I could use this in a "natural" hot tub
@rainbrothers
@rainbrothers 16 дней назад
Yes, you can. You’ll want to make sure it’s outdoors and that the ozone is turned off when people are inside the hot tub so they aren’t exposed to inhalation
@johnathankeller1948
@johnathankeller1948 17 дней назад
What part of the country are you guys installing this? And thanks for the videos
@rainbrothers
@rainbrothers 17 дней назад
Most of our work is in Ohio, but we also service parts of Indiana and Kentucky
@ChAmAkItO1987
@ChAmAkItO1987 20 дней назад
Thank you just the video I needed to see to understand the wiring
@bilodeau31
@bilodeau31 23 дня назад
I have a similar system, question though what is the pressure coming from the well pump to the tank? Mine runs at 100psi which seems high, would an expansion tank on that side of the system as well help?
@rainbrothers
@rainbrothers 23 дня назад
In our setup (mentioned in this video), the supply pipe coming from the well is just open pipe that pours into the top of the tank. If you have 100 PSI, then you have a valve closed somewhere or are using very small pipe… I don’t know how 100 PSI could develop against an open-ended pipe unless you have a monster of a pump on the other end.
@SalvadorAviles408
@SalvadorAviles408 23 дня назад
Hey cool video I honestly wasn’t sure how it got water I knew it didn’t have a pump but thought it was more complex seems simple enough
@vicentee2687
@vicentee2687 24 дня назад
need help I woke this morning and found mine melted
@rainbrothers
@rainbrothers 24 дня назад
Sorry to hear! Not sure how that could’ve happened unless the wires shorted out inside the pressure switch. But even then, your breaker should’ve tripped the moment a short happened. I would highly recommend contacting an electrician to get to the bottom of the issue. There could’ve been a surge in your system too but an electrician should be able to investigate and figure out the root cause
@vicentee2687
@vicentee2687 24 дня назад
@rainbrothers a tech came buy and it got hit by lightning pretty wild
@rainbrothers
@rainbrothers 22 дня назад
@@vicentee2687 Goodness! Glad it only affected your pressure switch. Glad you got it figured out
@TheEnigmaticmuse
@TheEnigmaticmuse 24 дня назад
I just don't understand how nobody has figured out the recipe for the self-healing Roman concrete yet. They already know they hot mixed quicklime and pozzolana with freelime clasts in it. Seems like someone who's familiar with hand making concrete could have worked out a recipe already.
@rainbrothers
@rainbrothers 24 дня назад
Yes, Roman concrete is pretty fascinating. However, concrete (Roman or otherwise) is not inherently waterproof - it still needs to be parged with a waterproofing cement on a regular basis
@TheEnigmaticmuse
@TheEnigmaticmuse 24 дня назад
@@rainbrothers I don't think so. The hot mixing of quicklime (i.e high temps), the alumina silicate of pozzolana combined with high mineral sea water and the late addition of free lime clasts into the mix allowed new mineral crystalline structures to grow when fissures and cracks formed and water flowed through them. That is why/how unmaintained underwater roman concrete structures stand to this day. Their chemical structure makes them....almost alive.
@TheEnigmaticmuse
@TheEnigmaticmuse 24 дня назад
@@rainbrothers if you install concrete cisterns, this might be something to experiment with in your free time. It doesn't have to be the exact ingredients they used, I would imagine, just chemically similar. The properties you're looking for in pozzolana would be alumino silicate; zeolite sand or clay, pumice sand or perlite. You would have to have quicklime, some of which you need small chunks of to throw in at the end of the mix. And limestone gravel. It looks like you'd have to make it yourself which isn't hard. Burn limestone in a fire until red hot. And clean water with a high mineral salt or a mixture of table salt, Epsom salt and borax. 4.64 oz per gallon.
@TheEnigmaticmuse
@TheEnigmaticmuse 24 дня назад
@@rainbrothers some variation of ingredients with these chemical properties along with hot mixing them is how they built their underground cisterns too.
@TheEnigmaticmuse
@TheEnigmaticmuse 24 дня назад
@@rainbrothers to this day, the Greek's and Italians use a pozzolana product to waterproof their pools. The Romans built it into their waterlogged structures.
@rafaelsandoval7077
@rafaelsandoval7077 26 дней назад
It's supposed to have a little gasket ring too. A lot of people forget to put it on The causes loss of pressure creates water flow and that's why your ground will be wet part of the time
@rainbrothers
@rainbrothers 24 дня назад
Yes, there is an o-ring inside the pitless assembly. There is also a larger, thicker external gasket, but that is used to seal the exterior to the wall of your well casing and wouldn’t have any impact on water pressure in the system (it would just impact having a good seal on the well to prevent surface water contamination).
@mrsillystrings4075
@mrsillystrings4075 26 дней назад
Neat
@thomasfinley7754
@thomasfinley7754 27 дней назад
My pump is falling off when it gets down to 40psi if I turn the breaker off and back on it will come back
@rainbrothers
@rainbrothers 26 дней назад
I don’t quite understand what you mean. Can you elaborate?
@noahfigueroarealestateagent
@noahfigueroarealestateagent 29 дней назад
Excellent video. Love the overflow safety feature. Do the pump savers work on 3 phase water well pumps (the pump that goes in the actual well itself)? I have heard you say they work on 110 or 220 but nothing about 3 phase. My water well is 3 phase.
@rainbrothers
@rainbrothers 29 дней назад
Great question! So, if this is a residential well, then you’re probably using a VFD pump that is single phase to the drive then three phase to the pump motor. Is that right? If so, your drive has built-in run-dry protection and you wouldn’t need a PumpSaver. Typically residential properties don’t have actual three phase power available, but VFD pumps are a different animal because they incorporate a single phase to three phase converter. If you truly have three phase, then, no, unfortunately our PumpSavers will not work
@ladyowl6743
@ladyowl6743 Месяц назад
😂 my step dad built a garage over their septic tank before selling thier house yrs later...
@rainbrothers
@rainbrothers Месяц назад
hahah oh noo
@johnqueen2754
@johnqueen2754 Месяц назад
Where did those white tanks come from. ?
@rainbrothers
@rainbrothers Месяц назад
Actually, we carry the tanks and supplies in this video: www.rainbrothers.com/store/Tanks-c82234042
@Sylvan_dB
@Sylvan_dB Месяц назад
Any thought to taking a hammer and breaking off that funky septic inlet? What about relocating the plumbing and wiring and patching the old, leaky holes? Nice job with the liner. Seems like a modular steel tank is the only excuse to plan to use a liner these days.
@rainbrothers
@rainbrothers Месяц назад
Breaking off the septic baffle could be done but is not necessary, and we try to avoid breaking any part of the tank if we can. Also, relocating the plumbing and patching the holes was not an option in this case as this tank is under a paved driveway, so the driveway would have to be ripped up to do that. Unfortunately it was poor placement and, according to the owner, the cistern has never held water above that water line since day one of the contractor installing it. A liner was a good option here, but, in most cases, parging with a waterproofing cement is the way to go
@gabrielrod22
@gabrielrod22 Месяц назад
This is a work of art!
@petersamios5409
@petersamios5409 Месяц назад
Nice job.
@brocklievsay8262
@brocklievsay8262 Месяц назад
how deep did you bury that and what is the frost depth like there? I'm looking to put one in, but frost depth is up to 6 feet deep worst case scenario and manufacture specifies 2 feet of dirt max from top of cistern to grade. would a 1500 gallon cistern like this freeze in those conditions? or would I need to insulate the top and sides of the cistern somehow. I read that 2" of foam is equal to 3.7 feet of dirt or something like that. Obviously theres many factors that can vary winter by winter like getting a bunch of snow early vs very dry cold winter. One winter the ground barely had frost in it from lots of snow early on. hadn't thought about integrating the pump inside of the tank so its still servicable without a seperate man sized manhole service hatch.
@rainbrothers
@rainbrothers Месяц назад
Here in Ohio, our frost level varies from 36-44”, and we always bury the tank with 16-18” of cover on top and that is more than sufficient to keep the water in the tank from freezing. There are thousands of cisterns here that have the top flush with grade (for instance, when the cistern is poured with the basement), and I’ve never seen water in those tanks even come close to freezing, though the water line will sometimes freeze. Our rule of thumb is: 16” on top of the tank, and bury the water line below frost level as it leaves the tank. Hope this helps
@Sylvan_dB
@Sylvan_dB Месяц назад
I ran the existing well pump wire to my cistern pump instead of the well pump, and ran a new line from a dedicated breaker to the well. Same end result, but no need to change the wiring around the pressure switch. Did the wiring in the box at the well instead of underground splicing.
@anthonyzarcone8696
@anthonyzarcone8696 Месяц назад
Cleanest well water I ever seen , great job
@bradmilligan2930
@bradmilligan2930 Месяц назад
Andrew Tate dropping actual useful knowledge
@rainbrothers
@rainbrothers Месяц назад
hahahaha
@alovsathuseynov6124
@alovsathuseynov6124 Месяц назад
Hello. It's a very good thing. I want to ask you how to control how much ozone is dissolved in water. Is there such a detector for this? Thank you.
@rainbrothers
@rainbrothers Месяц назад
No, unfortunately there’s nothing that could measure dosage other than experimentation and running the ozone generator on a timer
@1stSilversnow
@1stSilversnow Месяц назад
Hey! Great video, thank you. I’ve seen these systems in homes in the basement. How on earth does one of those 1000 gallon tanks get replaced when they’re in a basement? Seems a lot easier when you guys do this outside where it’s accessible.
@rainbrothers
@rainbrothers Месяц назад
Wow - I can’t say that I’ve seen a tank this size in a basement unless they built the basement around the tank. Luckily these plastic tanks last forever when removed from sunlight (ie inside or underground)
@1stSilversnow
@1stSilversnow Месяц назад
⁠@@rainbrothershey! Thanks for comment. It must have been built since the homes inception. Appreciate your time!
@rhondawhite5202
@rhondawhite5202 Месяц назад
Thanks for the great video!
@choochtech
@choochtech Месяц назад
Mine are not shutting off, on a shared well. It has been running non stop for three months and neighbor said power bill is crazy. How can i make them shut off? or has it gone bad? please help. I have this exact setup
@rainbrothers
@rainbrothers Месяц назад
Make sure that you are using a float switch that is rated for pump duty, like the ones on our website (www.rainbrothers.com ). If it is not a pump duty float switch, the internal switch won’t be able to handle the large electrical load of your pump and it will malfunction and stop working prematurely. You likely need to replace the float switch if it is currently not working
@coderOfFortune
@coderOfFortune Месяц назад
Neat setup. Where can I purchase the flush valve?
@michaelwright124
@michaelwright124 2 месяца назад
Thanks for this video. I am wanting to treat my well water thru a spin down filter and softener before I go into my cistern. Is there anything I should do to regulate my water from my well pump before it hits the softener?
@rainbrothers
@rainbrothers 2 месяца назад
If you treat the water before it enters the cistern/reservoir, you will need to keep your existing well pump tied to your existing pressure tank, and then get a second pressure tank for the new cistern pump. So then your cut/feed from the well to the cistern will be located after (downstream) from your treatment, and your cistern tie-in will come back to that same spot and carry on to supply your house.
@michaelwright124
@michaelwright124 Месяц назад
@@rainbrothers So using the pump saver device will not run the well pump? or is that it needs to be regulated to pass thru the softner?
@jeffa847
@jeffa847 2 месяца назад
I have a family friend who uses her pump only for watering the lawn. They seem to have sized her pump big and her pressure tank small so she has to run a ton of sprinklers simultaneously to try to get the pump to stay on instead of cycling on and off very frequently. The pump will turn on and off in 20 seconds then drain down pretty fast because she only has a 33 gallon tank (30/50 switch so I think that should give her 9 gallons of draw down or something. Anyway, forgive me for being dense but I couldn't conceptualize whether this would help with her problem. If she set her turn on pressure high like 55 and cut off pressure at 60 would that make the pump turn and stay on because it wants to keep the pressure up and even one sprinkler would keep it below 55 thus stopping the cycling? Gould 1hp submersible pump Well is 65 ft deep and the static water level was 15 ft. She doesn't know what depth the pump was placed at
@rainbrothers
@rainbrothers 2 месяца назад
This is a tricky issue to discuss without a full picture of the irrigation system and what each zone requires in terms of pressure and flow. Typically, irrigation zones have to be designed around the output of the pump, or you get issues like this. When we do irrigation systems, we install a Pump Start Relay tied in to the irrigation controller to turn on the pump every time a zone opens, and then we use a Pressure Relief Valve on the supply line to blow excess pressure back into the well/cistern/pond, and then you don’t even need a pressure tank. BUT, again, we only do that after careful work to ensure the pump matches the flow/pressure of each zone. Yes, you could use this as a possible solution, but I would expand the operating pressure differential instead of shrinking it if your goal is to reduce pump run time.
@rainbrothers
@rainbrothers 2 месяца назад
This is a tricky issue to discuss without a full picture of the irrigation system and what each zone requires in terms of pressure and flow. Typically, irrigation zones have to be designed around the output of the pump, or you get issues like this. When we do irrigation systems, we install a Pump Start Relay tied in to the irrigation controller to turn on the pump every time a zone opens, and then we use a Pressure Relief Valve on the supply line to blow excess pressure back into the well/cistern/pond, and then you don’t even need a pressure tank. BUT, again, we only do that after careful work to ensure the pump matches the flow/pressure of each zone. Yes, you could use this as a possible solution, but I would expand the operating pressure differential instead of shrinking it if your goal is to reduce pump run time.
@And3aPet
@And3aPet 2 месяца назад
Thank you! I repaired mine just now and it was indeed quite easy!
@gabrielrod22
@gabrielrod22 2 месяца назад
Great content, as always!
@rainbrothers
@rainbrothers 2 месяца назад
Much appreciated!
@alanwhitaker7919
@alanwhitaker7919 2 месяца назад
can they be run horizontally?
@rainbrothers
@rainbrothers 2 месяца назад
Yes
@stephengreen4716
@stephengreen4716 2 месяца назад
20 is my cut in point on a 20_40 switch. No matter where it goes the points chatter
@rainbrothers
@rainbrothers 2 месяца назад
You’ll have to tighten the smaller nut only inside your pressure switch. This will increase the start/stop differential. You’ll also want to make sure the pressure switch is installed as close as possible to the pressure tank. If it still chatters, you may have a bad pressure tank, need a new pressure switch, or use a pulsation plug in the bottom of your pressure switch (as a last resort)