saludo desde excelente la explicación le hago una pregunta. tengo el error 12.0 en mi derive que debería hacer para solucionar el problema o que me aconsejaría.
Alarm 12.0 *Causes* Voltage between P and N of the converter portion of the control power supply has exceeded the specified value 100 V version: approx. 200 VDC (approx. 140 VAC) 200 V version: approx. 400 VDC (approx. 280 VAC) 1) Power supply voltage has exceeded the permissible input voltage. Voltage surge due to the phase-advancing capacitor or UPS (Uninterruptible Power Supply) have occurred. 2) Disconnection of the regeneration discharge resistor 3)External regeneration resistor is not appropriate and could not absorb the regenerative energy. 4) External regeneration discharge resistor is not appropriate and could not absorb the regeneration energy. 5) Failure of servo driver (failure of the circuit) *Measures* Measure the voltage between lines of connector (L1, L2 and L3). 1) Enter correct voltage. Remove a phase- advancing capacitor. 2) Measure the resistance of the external resistor connected between terminal P - B of the driver. Replace the external resistor if the value is ∞. 3) Change the specified regeneration resistance value to wattage. 4) Change to the one with specified resistance and wattage. 5) Check that Pr0.16.
Protective function - A-phase wiring error protection Causes - A-phase wiring in the external scale is defective, e.g. discontinued. Measures - Check the A-phase wiring connection.
saludo desde Venezuela excelente la explicación le hago una pregunta. tengo el error 14.1 en mi derive que debería hacer para solucionar el problema o que me aconsejaría.
☺Causes Instantaneous power failure has occurred between L1 and L3 for longer period than the preset time with Pr5.09 (Main power off detecting time) while Pr5.08 (LV trip selection at the main power-off) is set to 1. Or the voltage between P and N of the converter portion of the main power supply has fallen below the specified value during Servo-ON. 100 V version: approx. 80 VDC (approx. 55 VAC) 200 V version: approx. 110 VDC (approx. 75 VAC) 1) Power supply voltage is low. Instantaneous power failure has occurred 2) Instantaneous power failure has occurred. 3) Lack of power capacity...Power supply voltage has fallen down due to inrush current at the main power-on. 4) Phase lack...3-phase input driver has been operated with single phase input. 5) Failure of servo driver (failure of the circuit) . . ☺Measures Measure the voltage between lines of connector (L1, L2 and L3). 1) Increase the power capacity. Change the power supply. Remove the causes of the shutdown of the magnetic contactor or the main power supply, then re-enter the power. 2) Set up the longer time to Pr5.09 (Main power off detecting time). Set up each phase of the power correctly. 3) Increase the power capacity. For the capacity, refer to P.2-10, "Driver and List of Applicable Peripheral Equipments" of Preparation. 4) Connect each phase of the power supply (L1, L2 and L3) correctly. For single phase, 100 V and 200 V driver, use L1 and L3. 5) Replace the driver with a new one.