Тёмный
GlobalHeatingCooling
GlobalHeatingCooling
GlobalHeatingCooling
Подписаться
Heating - Air Conditioning - Refrigeration - Ventilation
Gas Meter Is Leaking Gas From Neoprene Gasket
1:55
5 месяцев назад
45 PPM Carbon Monoxide In Boiler Room #DANGER
6:30
8 месяцев назад
Комментарии
@r8rO
@r8rO 19 дней назад
Uh uh 😂
@ChandanPal-qx2de
@ChandanPal-qx2de 25 дней назад
Thanks man
@CHIBA280CRV
@CHIBA280CRV 26 дней назад
What did he say he replaced , I can’t understand???? Doesn’t even show any parts?anyone
@ahmedsawni862
@ahmedsawni862 Месяц назад
Thank you so much for sharing the knowledge 👍
@WibbyKDX
@WibbyKDX 2 месяца назад
Sweet video dude. Very informative
@donaldturner1360
@donaldturner1360 2 месяца назад
Does it work with coil cleaner?
@JoseRodriguez-kx9gz
@JoseRodriguez-kx9gz 2 месяца назад
Where do you get the probes. Can the hoses alone be used?
@JoseRodriguez-kx9gz
@JoseRodriguez-kx9gz 2 месяца назад
I have that 510 but not the probes.
@JoseRodriguez-kx9gz
@JoseRodriguez-kx9gz 2 месяца назад
Can you do it without the probes. ?
@bills6946
@bills6946 2 месяца назад
It is not a 2 phase compressor. It is a single phase compressor at 240 volts. Both hot legs are center tapped in the distribution transformer as a delta configuration to create the neutral for 240 volts, hot to neutral is 120 volts. If it were derived from a wye configuration, it would be 120/208 volts the common from both legs is the neutral
@KINGPAFA
@KINGPAFA 2 месяца назад
??? It is a 3 phase 575 v Scroll compressor!
@steveway7981
@steveway7981 3 месяца назад
Dude, really? Do you got to have that f****** thing beeping
@JohnLennon-yg4ut
@JohnLennon-yg4ut 4 месяца назад
unwatchable. every other word is “uh” *heavy breathing “ uhhh” more heavy breathing. You sound like a Neanderthal
@deddie4645
@deddie4645 4 месяца назад
Would one of you you 2 people at least give the same information you tested the same voltage or test it at double the voltage ratedV
@kevinortiz7332
@kevinortiz7332 4 месяца назад
I would be very grateful if someone could tell me if they have or should buy an air conditioner.
@kevinortiz7332
@kevinortiz7332 4 месяца назад
I'm looking for how to make it turn on if it has one. or not?
@kevinortiz7332
@kevinortiz7332 4 месяца назад
Does this system have cold air or not?
@calebcrockett1085
@calebcrockett1085 4 месяца назад
Hey thanks for making this video, been doing HVAC for 3 years but moved over to installs to help them out within the last few months. Currently all my tools are just thrown in a 5 gallon bucket so you definitely gave me some ideas!
@chrishanse100
@chrishanse100 4 месяца назад
Useless
@tS-sn7jt
@tS-sn7jt 4 месяца назад
Useless video
@Freonleon
@Freonleon 5 месяцев назад
Copeland bulletin When using megohmeters to evaluate the motor insulation of compressors, it is important to understand that they should not be used as one would a volt-ohm meter. A single megohmeter reading gives little insight into the condition of a motor’s insulation. Megohmeters are best used as a part of a regular maintenance program to monitor trends (over several months). For example, one might record a megohm value and compare it to a previous reading. If subsequent readings show a trend of lower and lower values, then corrective action (such as system clean up) should be taken. Emerson does not incorporate the megohmeter into any of its quality checks. All Copeland® compressors must pass U.L. required tests using hi-potential current leakage testers (“hi-pot”). Studies performed by Emerson have found that compressors with megohmeter readings as low as 0.5 megohms still pass the hi-pot. There are many factors that affect megohm readings including contaminated refrigerant, oil level, refrigerant in oil and current leakage through electrical fusites or terminal plates. © 2010 Emerson Climate Technologies Printed in the U.S.A. Any external electrical components connected to the compressor terminals also affect megohm readings. Wires, contactors and relays all leak current and will decrease compressor megohmeter readings if not disconnected. As mentioned earlier a single megohm reading cannot be used to condemn a compressor since many other factors are involved. However, limits can be placed on megohm values that dictate action be taken. Emerson has found that these limits are related to the rated voltage of the compressor. Megohm values equal to or greater than 1000 ohms per volt are probably acceptable. For example, a 460 volt compressor might show a megohm reading of 460,000 ohms or 0.46 megohm. Compressors with rated voltages of 208 to 230 volts would then be operable at megohm values of 0.208 to 0.230 megohms; for simplicity, Emerson has set the limit at 0.5 megohms before a compressor is condemned. Figure 1 shows the required procedure for checking compressors with a megohmeter. New compressors that have never been installed will not need any system clean-up procedures so long as the megohm reading is above 0.5. A baseline reading must be established for comparison purposes and since this is its first
@bailielaland6555
@bailielaland6555 7 месяцев назад
🔥 'PromoSM'
@pacospete4299
@pacospete4299 8 месяцев назад
so i'm seeing folks install these mini split systems ans coiling the access lines next to the outside unit .... is this a problem ?
@WireWeHere
@WireWeHere 8 месяцев назад
1990 John Wood NG-HWHT to 2007. 2007 John Wood NG-HWHT to 2024 2024 John Wood NG-HWHT to 2041ish? Flushed every 6 months and always equipped with an expansion tank. Only outlasted by our cats, Diane 24 and her sister Maryanne 26, Figo 23, and his sister Ninha is still kicking at 24 years of beds, dishes and toys washed only with water heated by John Wood.
@SupremeRuleroftheWorld
@SupremeRuleroftheWorld 8 месяцев назад
so, technically a third of that compressor is still good. put it back in and send it!
@gyver471
@gyver471 8 месяцев назад
I thought these had low water cut off built in.
@evezford
@evezford 9 месяцев назад
This is called “No Heat Call” yet it didn’t mention that at all!
@Alienspecies635
@Alienspecies635 12 дней назад
when the damper doesnt open the boiler wont turn on that means theres no heat, aka no heat call. sequence of operations is the damper opens firsts, luckily you can bypass the damper by flpping the switch as he did and now the heat works.
@Electric-Air-Service
@Electric-Air-Service 10 месяцев назад
Very good video..
@cowoganteng3776
@cowoganteng3776 Год назад
👍👍👍🙏🙏🙏🙏🙏
@williamwalker-bm5mz
@williamwalker-bm5mz Год назад
The video was useless
@KINGPAFA
@KINGPAFA Год назад
LOL!
@saner6888
@saner6888 Год назад
Where is the filter on this unit and is there just one? I believe this is the unit I had installed TY
@TheLandlordPicker
@TheLandlordPicker Год назад
What did you do to fix it?????
@denisvandecker8275
@denisvandecker8275 Год назад
That was a waste of time video. People are expecting How To not just hey look I fixed it.
@bhushank7420
@bhushank7420 Год назад
Just wondering if you’ll be kind to help me with Raypak H3-514 boiler.
@tcmazz
@tcmazz Год назад
Yeap what was the point of the video? I agree with everyone useless
@djluck95
@djluck95 Год назад
If you were a real Samsung technician you would have used the Samsungs diagnostic cable to say 100% that the board is bad, not just guessing ... "another well done job"
@KINGPAFA
@KINGPAFA Год назад
Lmho.
@robertplas3947
@robertplas3947 Год назад
Please re-title your video to my Raypak pool heater was fix. Awful title and very misleading.
@arx9z
@arx9z Год назад
just found your channel and love the videos. Where do you get most of your hydronic parts in Toronto?
@tS-sn7jt
@tS-sn7jt Год назад
Hey what’s the point of your video
@dfx7105
@dfx7105 Год назад
We've all been in the bushes
@dougthegreat1808
@dougthegreat1808 Год назад
USELESS
@partshnc
@partshnc Год назад
Every stage in the installation procedure has been broken down into clear, thorough explanations that are simple to follow. We provide quality Raypack pool heater spare parts, in case anyone is in need of them.
@BlacHaze78
@BlacHaze78 Год назад
You’re video is terrible
@jasonfoster9118
@jasonfoster9118 Год назад
I'd like to make a correction. Anything less than 1 Megaohm is considered a failure, while in reality, I've seen motors run with less than that. 50 Megaohms is a very good reading.
@Michelle-lk6lu
@Michelle-lk6lu Год назад
HOW do you light the pilot??
@xigam1975
@xigam1975 Год назад
That's what I'd like to know.. where do you put the flame to light the pilot..
@timothymcmahon1507
@timothymcmahon1507 Год назад
@@xigam1975at the end of the metal tube
@posplaytime801
@posplaytime801 Год назад
Why post a video like this??
@wtp5
@wtp5 Год назад
This is useless
@herbertgarcia4297
@herbertgarcia4297 Год назад
How did you fix it????
@globalheatingcooling
@globalheatingcooling Год назад
Changed The Powerpile.
@omarbuchanan6283
@omarbuchanan6283 Год назад
I have a Raypak 406A which is not clicking. What is a "powerpile"
@natemiller7841
@natemiller7841 4 месяца назад
​@@omarbuchanan6283same here, did you figure it out ?
@Victor-r3m7e
@Victor-r3m7e 3 месяца назад
Mine clicks but doesn't seem like it's running?
@chhuangaralte2078
@chhuangaralte2078 Год назад
Who wa t to swap Fluke 87 V MAX with Fluke 1507
@josepholuwasheyifunmi8782
@josepholuwasheyifunmi8782 Год назад
Please, can i do the same test with Fluke 115 multimeter?
@KINGPAFA
@KINGPAFA Год назад
No, with a multimeter, you could only test to see if the compressor is grounded or not! An insulation tester will test the condition of the insulation on windings, whether it is good or bad or on its way out!
@hamidab1639
@hamidab1639 Год назад
Thanks for easy explanstion
@aday1637
@aday1637 Год назад
Having been a service man for a Carrier commercial contractor, I've seen that brand be dud when new as well. Check valves distorted during install due to heat leaving bypass and low performance on a 2 stage system. Trying to figure that one out was a duzzie. And repair was even more so. We had to tear the entire system apart to access the valve and replace it. Customer was a dentist with 3 systems and could never get one area cool on hot days. I personally did heat gain calcs in an effort to figure out the culprit. Unit would produce some production which made things more dicey. It's part of business in America (and elsewhere).