Hello Everyone, 🙏 This is my RU-vid Channel " Electrical Work - Learn Easy " I upload Videos related to House Electrical Wiring. This video will be totally in Hindi language. I will try to give you all the knowledge of wires, MCBs, Switches, Sockets and Connection doing. I will try my best to teach you in the best simple way to make easy for you to understand and practice.
Video pura hindi language main hoga. Koi sawal ho toh video main comment jarur kijiyega.
What type of electrical wires are used at Home . What are the rules for House Wiring. What is normal house wiring size. How to select wires size for house wiring. How to select mcb size. Load ke hisab se wire ka selection kaise kare. Mcb kitne types ke hote hai. Wire gauge kya hota hai. Wattage, ampere, current, voltage kya hota hai. Hp, kw, kwh, kva, kya hota hai electrical wiring main. House wiring materials name. Tools for house wiring.
Video achha lage toh plz channel ko subscribe kar digiyega🙏 Thank you.
Jo ye Douple pole mcb hota hai jyadatar main mcb board main use kiya jata hai.. Yani meter ke baad.. Aur dp mcb ke baad single pole mcb lagaya jata hai.. Aap switch ke sath bhi laga sakte hai.. Lekin lagana hi chahate hai toh single pole mcb lagaye..
सर जी एक बात मै यहा कहना चाहुंगा कल ही मैने okaya 1250 इन्व्हर्टर खरिदा अमेझॉन से और इन्व्हर्टर के out put सॉकेट मै लेफ्ट side मै फेस है... So that हर कोई पहले इन्व्हर्टर शुरु करे, और टेस्टर से out put सॉकेट के किस तरफ फेस है वह बात जान ले 🙏🏻 बढिया यही होगा के बुकलेट पढ के इन्व्हर्टर, बॅटरी को समझ ले 🙏🏻
Ji aapne bilkul sahi kaha.. Inverter ke output socket ko check karna jaruri hai.. Ki kis side pe phase aa raha hai.. Taki aapka wiring sahi tarike se ho.. Jyada tar inverter ke right side pe phase hota hai
Thanks for the video; you are such a wonder teacher. I enjoyed watching it from Nigeria 🇳🇬. When I bought my PowerMax inverter. While on (ups mode) whenever my MAINS input is less than 180 volts. The inverter switches to backup mode and stops using the MAINS to charge the battery. But after watching this video, I'm planning to switch my selection mode to inverter mode, and I hope I will be able to charge my battery even when the MAINS input voltage drops a little below 180v (for example, 150v).
Thank you for watching my videos.. I really appreciate 🙏🙏 If you main supply voltage goes below 180 always keep your inverter on eco mode/normal mode..
Ups me jab woh light aa rahi hoti hai toh woh discharge kyun hota hai ??? 2nd mera 700 va ka livgaurd ka inverter hai mere yaha voltage uper niche hote rahte hai aur power cut bhi lagta hai meri battery 150ah ki hai Livgaurd ka ups mode use kar sakta hoon kya me pc ke liye agar haan toh uska ups mode kaha hota hai
Ups mode ko banaya hi uss tara se gaya hota hai.. Main line hone par bhi Battery discharge hota rehta hai.. Main line ka kaam lagatar battery ko charge karta rehta hai.. 2) Ups mode me voltage 180 se 270 tak hota hai. Agar aap ke ghar ka voltage 180 se niche nahi jata hai aur 270 se upar nahi jata hai fluctuation hone par.. Toh aap ups mode pe rakh sakte ho.. 3) liv guard kon sa model inverter hai?
Agar Inverter ke back side main Reg and Unreg likha huwa hai toh Req mode par rakhiye.. Reg ka matlab UPS mode hai.. aur Unreg ka matlab Normal mode hai..
@@vishalshakya4393 aisa toh nahi hona chahiye.. Ups mode par toh wifi switchoff ya restart nahi hona chahiye.. Aap ke ghar main voltage kitna aa raha hai?
Bhai meter k PASS only kutout fuse lage huye h netural aur phase m .yadi fuse ko hatakar ghar m board m switch aur socket change kre to dono wire m hath lagne se current to nhi lagega kya
Nahi lagega bhai.. Kyuki ghar main line fuse ke through hi aa raha hai.. Fuse nikal denge toh supply bandh ho jayega aur aap bijli fitting ka kaam kar sakte hai🙏
Ac current main 220 se 240 volt hota hai... Agar 1 sqmm wire ka 10 amp capacity hai toh 2000 watt tak ka electrical appliances uss wire pe connect kar sakte hai.. Lekin DC main 12 volt, 24volt, 48 volt hota hai jaise ki hum inverter use karte hai.. Same wire 10 amp ko dc voltage 12 se multiply kare toh 10amp × 12 volt = 120 watt ka load hi jod sakte hai.. Jitna DC battery ka volt badega utna hi load capacity Badega
Jo ye do circuit breaker hai.. Isme neutral aur phase ka terminal diya hota hai.. Aur jo single pole mcb hota hai usme sirf 1 terminal hota hai phase wire ke liye.. Aur neutral wire direct load se connect kiya jata hai ya fir neutral bar rakha jata hai.. Isliye dp switch ya dp mcb meter ke baad lagaya jata hai.. Jaruri nahi hai ki lagana hi chahiye.. Budget ke hisab se hota hai.. Meter ke baad Main switch bhi laga sakte hai ya single kitkat fuse bhi laga sakte ho..jo sasta mil jata hai.. aur kaam bhi achxhay se karega.. 🙏
Ji jaruri hai.. Kyuki agar app sirf 2 way switch ka use karenge toh ya toh inverter se chalega ya toh Main line se chalega.. Bulb ya socket ko off bhi toh karna padega.. Isliye normal switch jaruri hai..
@@ElectricalWork-LearnEasy-56 abh tik hogaya bhai uska naam nahi patha hai but Digital Home UPS lika hai and reset button bhi nahi hai bhai Thanks for replay☺
Kya 25a ka mcb switch lagwa sakte hai? Kya ye safe hai? Mere geyser 2000 watts ka hai aur mere electrician 16a switch aur 25a ka single pole mcb laga gaya. Koi safety issue ya risk ho sakta hai? Kindly reply. Thanks.
Koi risk nahi hai... Geyser ke liye Mcb jyada amp ka ho gaya ..16 amp B type mcb lagana chahiye tha.. Fir bhi koi problem nahi hoga.. Acchay se kaam karega 🙏
Dc current voltage ke upar depend karta hai.. Kitna volt ka battery hai. Eg.. . 12,24,48,64 volt ..500 watt load hai toh dc 12 volt main 42 amp, 24 volt hai toh 21 amp(current) etc
Rccb toh aapko online 1200 main bhi mil raha aur 2100 rs ka v mil raha hai.. Company dekh ke hota hai.. Schneider, hager ka rcbo ka price dekhiye.. Rcbo ka price jyada hota hai agar aap same company ka rccb aur rcbo lete hai toh
In Simpleword..Inverter convert dc power to Ac.. The power store in the battery is used when the main Line goes off.. When the main line comes inverter stops its supply and the battery starts charging..
Kyuki motor ek inductive load hai.. Jitna power woh khich ta hai utna output main use nahi hota hai.. Sirf 80 se 85% hi use hots hai.. Is liye hum 80% ko 0.8 likh te hai..
Hamari Area ki Transformer 25 Amp Ka Hai Voltage 130-180 Aati hai Meine 5 kva ka stabilizer liya hai output voltage 220-270 Aati hai But jab Meine electric auto charging me lagwa hai tab output voltage 185-190 Aajate hai please solution dijiye
Thanks for this information sir i am very confused that which mode i have to select you helped me a lot I have a desktop when the light is gone the computer off and automatically restart