Consumption factor is based on types of DG, , oem coupling, connected load , RPM, frequency and especially hands on experience. It is also validated by one of well reputed DG manufacturers after watching my video which confirmed their product tech specs Best regards Best regards
You are referring to assumption the DG is 100% efficient. If let says it is only 80% generating energy, then 0.26 liters / 0.8=0.325 liters per kWh. What it says, it consume more diesel just to produce 1 kWh electricity. Unless your 0.26 liter per kWh has already accounted for inefficiency. Load is only talking about how long it runs, not efficiency
I m not saying here that dg is 100% efficient. FOS of any machine is 20% as per gep. Dg assemler designs it on 100% load. But keeping overload n underload norms, it is more efficient at 75% load considering all balanced loads on three phases. It is just like the Car having 240KMH meter, cannot run on 240KMH constantly. So watch again this video carefully where at the end i addressed such issue Best regards
@rinkusingh18595 geared motor ki out put shaft ko driving shaft manein gay. Osky jo bhi rpm hongey osko machine k sath connected driven sprocket ya driven puley k rpm ko formula ma dalein gey
If it is not functioning properly, loss of air pressure, oil mixing in air due to eroded moving parts, abnormal noise and excessive vibrations due to eroded parts So it is recommended to go overhauling of compressor, ring piston change liners change connecting rod change valve change, head facing and allied machining works etc Best Regards
85kVA = 68kW 85kVA DG will consume fuel as follows 17.68lires at full load 13.26litres at 75% load 8.84 litres at 50% load 7.07 litres in 40% load best Regards
45 Litres lube oil is filled in 220kVA DG. Secondly recommende oil grade is 15/40W. We prefer to use here shell delo gold lubricant considering local weather conditions Best regards
Filter to be used are of fleet guard are the best. Perkins Cummins etc dg assemblers buy from fleetguard and just stamps their make like perkins, Cat, Cummins, ATS etc
Thanks my brother Kindly share with your friends and also watch playlist videos on bearing, Diesel generator, power transmission, pump n seals, HVAC etc Best Regards
Welcome my brother Kindly share with your friends and also watch playlist videos on bearing, Diesel generator, power transmission, pump n seals, HVAC etc. Best Regards
19900Btu/hr = 5833 Watt cooling EER=cooling in watt/ power consumption in Watt Please share name plate as this unit is drawing Current ranging from 0.52 to 2.06 amperes which is not normal current of If ac units of 18800Btu/hour (
Kindly share power consumption in Watt which definitely 1300 to 1500 watt As per provided amperes 0.2 to 2.06, unit can not operate to provide 19900 But/hour cooling, it can be at this stage with less than 1000btu/hr cooling.
20 rpm NAHI hota. DG normal RPM are 1500 and high upto 1800. It can control from AVR by resitting frequency at 50HZ if is is not adjusted to desire rpm, pls check governor functioning and also check fuel injection system thoroughly and calibrate if required. oil pump malfunctioning also shows this problem, check rotor chrome of pump as well Best Regards
It was done during raining season. In dry summer hot weather when humidity is less than 20% , dewatering is required to make good connection in earthpit. Normally we do earthing when water table is reached depending upon region wise site constraints. Water table is available from 20 feet to 350ft normally in Pakistan Best Regards
This video is mentioning the aspects of excessive vibration level The peoples have hands on experience and dealing with maintenance of Genset are well aware of that. Further, if you will judge here the intensity of vibrations creating due to non availability of fasteners in canopy and foundations pads and also weak anti vibration pads between Genset & canopy base frame you can't ask to do so. You can easily asses vibration while switching ON (start) and switching OFF DG which leads to damage engine coupling, engine legs, foundations, and other allied accessories of DG etc. I have uploaded another video on same issue by using of vibration meter to measure vibration level. You can easily understand what I am doing there for. I will uploaded soon the video where DG legs were damaged due to excessive vibrations. It is hoped that you are now satisfied in response of your query Best Regards
Thanks kindly share with your friends and also watch channel playlist videos on bearing, pump n seals, generator, power transmission and HVAC when convenient Best regards
C3 clearance of 50mm ID bearing is greater than Normal clearance. The values of minimum radial clearance is 0.023mm (23microns) and max radial clearance is 0.043mm (43micron) for ball bearing.similarly for other types of bearing, min and max clearances will be slightly changed in thous. For for 40mm Id (6208/6308/6008). min and max C3 bearing clearances will be 0.015mm(15micron) and 0.033mm (33microns) respectively Further, standard/normal clearance of 50mm ID bearing ( 6010/6210/6310) will be 0.008mm(8 microns) and 0.028mm (28microns) respectively Best Regards
Thanks. Kindly share with your friends and also watch playlist videos on bearing, Diesel Generator, pump n seals, power transmission, HVAC and boiler fuel consumption calculation formula Best Regards
@@Khadarmarampally you can watch bearing od, bearing thickness, bearing id, bearing suffix, etc in my channel playlist namely bearing for further clarification Kindly feel free to contact if need any further clarification Best regards
@@mechanicalengineeringpract140 ok sir.i mention the above bearing is used in maruti Suzuki 800 ;5 speed dx vehicle.it is the input shaft R bearing.but the bearing in different in Normal Maruti 800.i think the bearing is also same as Alto standard.5 speed 800 is Stop production in coming of alto
Absolutely heat treatment can do this subject to furnace treatment you adopts Types of heat treatment can hardness, tempering after annealing, quenching and finally normalizing etc. and types of furnace to be used at particular temperature Best Regards
Kindly watch bearing OD videos on medium series, light series n heavy series available playlist namely Bearing for enhance clarity how to find OD of any bearing Best Regards
Thanks kindly watch also channel playlist videos namely Bearing, Diesel Generator, power transmission, pump n seals, HVAC etc. please share with your friends also if it is informative and helpful for you Again thanks for your valuable comments Best Regards Best Regards
Thanks, kindly share with your Friends and also watch playlist videos on bearing, diesel generator, power transmission, HVAC, pump n seals Best regards