Hello friends , This is me SAFDAR KHAN KAYANI. I am M.Sc chemistry from university of Karachi . And I am having 14-years experience of pharmaceuticals industry. My this channel voice of kayani based on 1- pharmaceutical Technical industrial data, 2- knowledge on pharmaceutical technical operations. 3- pharmaceutical industrial instruments, 4- pharmaceutical documents 5- pharmaceutical industry sop's. 6-HPLC instrument. 7- GC instrument. 8- good documentation. 9- training system. 10- industrial operation 11-HPLC 12- HPLC operation 13- HPLC troubleshooting 14- quality control department and so on.. So guys be connected with channel to get knowledge about quality control department and about pharmaceutical industrial document.
Hello sir, Main Agar mobile phase ko A port me rakhta hu to Port B me washing ke liye kounsa solution or Rinsing Port me kaunsa solution fill kr skta hu
@@kumarharshit6744 rinsing solvent 50% methanol hota hai and B port Mai washing solvent hoga depends k Apne mobile phase Kiya chalaya hai us lehaz se washing solvent hoga
Hello sir, Main Agar mobile phase ko A port me rakhta hu to Port B me washing ke liye kounsa solution or Rinsing Port me kaunsa solution fill kr skta hu
@vasudevsharma-ey6ni bhot bara role hai leaks at detector count hoga agar damages Hain ya dirty hai... In cases of leak causes baseline noise... So must be in proper condition
No. Of injections to analysis complete hone ke baad hi entry hogi sir .....matlb koi analysis 21 ko start hui aur 22 ko khtam hui to us case me column usage me ye entry 22 ko hogi
No dear. Entry date 21 hogi that is usage date and no of injection ap next day complete honai pe bhi likh saktai hain and pehlai bhi according to sequence file....
Sir recommend some washing solvent composition for colouman washing 50:50 water : ACN is best and can we use pure ACN and methanol as washing solvent in ODS colouman
You use graduated pipette but not in Assay testing., Bcz in Assay you need accurate volume which is possible by bulb pipette and not by graduated pipette. For accurate volume use always bulb pipette
Not so specific time.... Depends on case ,, normally within 2 to 3 days or in 1 day ..... It depends on situation but need to complete as soon as possible
Company ka structure daikhoand apna temperament daikhain pair bond sign karo... In other words bond Mai problems aa saktai hain ...agar ap kisi bhi Tarah k problems ko face kar saktai ho to join karo warna bond pe nai
@@voiceofkayani5419 Formaldehyde solution ko ppm may krna hy suppose 5 ppm may krna hy Or uv may absorbance laty hin us ko ppm may calculate krna hy ya clear krdain
Sir RSD pr bhi video bnaye main jab bhi shimadzu pr sample lgata hun meri kabhi bhi Rsd fail ni hoti 0.03 tak bhi aati h lekin waters k system pr kabhi kabhi Rsd fail ho jati h.. mujhe to waters pr sample lgate hue dar lgta h plz sir waters ki Rsd pr video bnaye ki Rsd fail na ho 😢
نائیس صفدر بھائی۔صفدر بھائی ایک بات تو بتادیں۔ بھائی یہ یو وی اسپکٹرواسکوپی کے لئے ھمیں عموما کتنے ppm کے سولوشن بنانا چاھئے،یعنی رینج بتا دیں کہ اتنے پی پی ایم تک کے سولوشن بنائے جاتے ھیں یو وی اسپکٹرواسکوپی کے لیے۔۔۔ اور دوسری بات یہ کہ یو وی اسپکٹرواسکوپی میں ھمیں ایبزوربینس رینج کیا لینا چاھئے؟ یعنی ھمارا ریزلٹ کس رینج میں ویلیڈ ھو گا؟ شکریہ
PPM ka solution depends k compound ki nature Kiya hai us lehaz se hota hai., 2nd spectroscopy Mai kaam Visible range 400 to 800nm hai and uv rand 200 to 400 hai round off... Aki ye bhi compound ki nature pe depend hai k wo kis range Mai maximum response show kar raha hai usi lehaz se range bhi set hoti hai.. Baki details video Mai Bata dunga Thanks
@@voiceofkayani5419 شکریہ صفدر بھائی،یہ بھی بتا دیں کہ absorbance کی ویلیو کیا ھونا چاھئے؟جیسا کہ ھم جانتے ھیں کہ 0،1 سے 0،8 کے درمیان ایبزوربینس لی جاتی ھے،کیا یہ بات درست ھے؟
@@voiceofkayani5419 آپ سے ایک ریکوئیسٹ کرونگا کہ کوئی ایسا طریقہ سمجھا دیں کہ یو وی اسپکٹرواسکوپی کا استعمال کرتے ھوئے ھم ایک مکسچر کی اینالیسیس کر سکیں جس میں دو یا تین کمپاونڈز ھوں،ابھی تک میں نے یو وی اسپکٹرواسکوپی صرف ایک سنگل کمپاونڈ کا assay معلوم کرنے کے لیے استعمال کیا ھے۔