Hey, my name is Luke! HMI/SCADA Specialist & SCADA World founder Sharing is who I am, and teaching is where I am at my best. Teaching is my way to be a part of the engineering community.
I am a SCADA specialist and a certified SCADA instructor. With 10 years of SCADA programming and development team support, I created and helped build over 130 SCADA systems over the world (various vendors: WinCC V7, WinCC Flexible, WinCC TIA, Wonderware InTouch, Factory Talk). In the constantly changing field of the SCADA market, it is my mission to provide you skills and knowledge needed to become SCADA Engineer, Automation Engineer, or Control Engineer in near future. With the skills you learn here you can show the perfect portfolio.
printf("hello"); int* test = "LI8421.ALM1"; So the int* test line had no errors before adding the printf line, but after adding it i now get an error "<ident> expected before int". Do you have any idea why that would be?
In my wincc project , when a button is pressed with left key of mouse and also at same time spacebad is pressed then button gets latched , it causes operation issue. Please help . And button is assigned with c-action
I followed all the steps, but running the script doesn't open the PDF. I tried with multiple PDFs, and none of them open. Additionally, I don't see any errors in the GSC Diagnostics running in the background. Could it be that my Foxit version is too new? Thank you for the effort you put into these tutorials. Keep it up!
Sir actually i am using wincc v8 in pc. I have installed two license there wincc rt+ Configuration and wincc arch. But, when i activate the rt, there show 1 pop up that server license is missing ...so what is this ??plz reply..
thank you for the video, how can i filter the alarm messages based on a variable "contains text" instead of a static text ? I mean to write a code in VBA or C that filters based on variable motor_name , and the motor_name is a string
heloo sir i am facing a little issue here . I installed the WinCC classic V7.50 and when I try to open my projects that are created on version v7.2 and v6.2 both are showing the error message "you are trying to open a project file which has been created with a newer WinCC version than the currently installed one" but i am using the latest version. I tried using the project migrator but it says " not need Its already up-to-date " waiting for your reply
Hi SCADAWorld! I'm using WinCC V7.5 SP2 for my project, which involves both a server and a client. I've configured the client WinCC (without a project). However, when I interconnect with the server in Simatic Shell from the client, the runtime displays, but it says, "Start picture not found. Please configure the desired picture." I've already configured the startup picture in both the server and client, but the problem still persists. Can you help me solve this issue?
Hello I used your script and also I incorporate Tag based triggering for automatic appending of data. I encountered a problem from which the logs append twice and even three times. Maybe you can help me get rid of this problem? please?
Thanks for the video: Another maybe simpler code for toggle without using "if statement" is: HMIRuntime.Tags("OUTPUT_BINARY").Write(1 - HMIRuntime.Tags("OUTPUT_BINARY").Read)