Danny Noorian is a red seal refrigeration mechanic and also the owner of Below 4 Refrigeration Ltd. Ever since he was 8 years old he always had a passion for commercial refrigeration and entrepreneurship. His passion for refrigeration most likely came from past generations because his dad and grandpa were also in the refrigeration industry. Danny received his red seal certificate in 2016 and started Below 4 Refrigeration Ltd the same year. Below 4 Refrigeration Ltd. is now becoming one of the fastest growing refrigeration companies in British Columbia.
Great presentation. Like others have mentioned, in the classic legislation environment, where you are just pulling water from the tap to cool the condenser, yes - these are generally not eco friendly. However IMO, if you have a lake, a geothermal system, a small chiller, or the equivalent, you are much better off with the water cooled system.
Yeah the video failed to mention each manufacturer sets the controler differently. Press and hold longer and enter access code 22. Then find C1 . Hope this is helpful. You can also find the chart symbols online easily .
I would remove the entire EVAP coils and take outside to clean.. then completely let it sun dry.. Same with the fans... remove , take outside to clean.
Mistakes friend,first defrost the evaporator,the valve allready is working low superheated and liquid is flooding in compresor.You "fixed it the opposite way",you destroyed it...haha
I have a true drink cooler it was freezing the drinks no matter the setting it was on I replaced with a new thermostat off eBay and it will not cool below 50 degrees 831932 part number idk if you have any idea thank you
Depends on the model of the true cooler you have. Each true equipment has a different type of thermostat. Call true mfg and they will give you the correct part number, then you can buy off www.partstown.com
You are using more refrigerant to cool the water in an exterior motion, and a pump which uses electricity to pump the water that the condenser is submerged in to merely achieve greater results all legal
All you must do is put the coil submerged in water, circulate the water with the pump to a reservoir of cold or water, using the same principle of AC to cool the condensing unit in no time the transfer of heat will be much greater
Hello partner on duty! A got some kind of troubleshooting this type of problems... This time was a low ppressure in liquid line just afte filter drier (160psi) and quite good pressure in low side after evap n Comp rotalock (18-20psi) for a 404a walking in freezer meat storage. Txv and beyond still froozen. Sight glass is clear most the time then just flush ... I know is full, Maybe refull of refrigerante the entire system. Good both sides vents, cond-evap were washed. Help me, dont wanna loose this client😢
But this is absolute rubbish for repairing household refrigerators. I have been professionally repairing household appliances for more than 20 years. I have tried various seals from time to time. None of them give a significant result.
Why you have to adjust the txv if it was working properly before?looking at your suction pressure and considering that the evap coil have some ice i assume you have overcharged the system.Also you dont measure superheat without cleaning the ice of the evap coil first
....and if that doesn't help....?!? Bridge was near ½" on Default-setting. Moving it to the right, decreased it to about ¼"....but still too thick......