Тёмный
Dnoorian
Dnoorian
Dnoorian
Подписаться
Danny Noorian is a red seal refrigeration mechanic and also the owner of Below 4 Refrigeration Ltd. Ever since he was 8 years old he always had a passion for commercial refrigeration and entrepreneurship. His passion for refrigeration most likely came from past generations because his dad and grandpa were also in the refrigeration industry. Danny received his red seal certificate in 2016 and started Below 4 Refrigeration Ltd the same year. Below 4 Refrigeration Ltd. is now becoming one of the fastest growing refrigeration companies in British Columbia.
TOP 10 HVACR TECHS YOU SHOULD FOLLOW
21:59
4 года назад
SINGLE PHASE COMPRESSOR WIRING
8:39
4 года назад
PRODUCT REVIEW #1: EasySeal UV DYE
9:38
4 года назад
WALK IN COOLER DOOR LOCK FIXED
23:24
4 года назад
Refrigeration Dye: Worth the Fix?
2:23
4 года назад
INSIDE A SHORTED ROTARY COMPRESSOR
13:57
5 лет назад
WELCOME TO MY YOUTUBE CHANNEL
0:57
5 лет назад
HOW TO FIX A LEAKY SIGHT GLASS
2:03
5 лет назад
Комментарии
@StoweLauren-t1c
@StoweLauren-t1c 2 часа назад
Hernandez Jeffrey Lee Margaret Wilson Joseph
@MacAdamAlice
@MacAdamAlice 23 часа назад
Smith Jennifer Martin Lisa Allen Nancy
@BaconShuffler
@BaconShuffler 3 дня назад
How did you even remove the evap/condenser from the pop cooler?
@douglaslopez8058
@douglaslopez8058 9 дней назад
A you forgot to. Put another of water hose
@petersamios5409
@petersamios5409 12 дней назад
Great presentation. Like others have mentioned, in the classic legislation environment, where you are just pulling water from the tap to cool the condenser, yes - these are generally not eco friendly. However IMO, if you have a lake, a geothermal system, a small chiller, or the equivalent, you are much better off with the water cooled system.
@popsmccartney435
@popsmccartney435 16 дней назад
Thanks for sharing
@mrsexytime_
@mrsexytime_ 24 дня назад
The only explanation on youtube that is real and helpful.
@noneofyourbusiness9236
@noneofyourbusiness9236 26 дней назад
Really!!! Spraying that crap in a fruit freezer???, Is this guy a IDIOT, or just from some Country that doesn't know better? What a IDIOT!
@MiroHaidari
@MiroHaidari Месяц назад
Thank you for your information
@rishikkeshari6306
@rishikkeshari6306 2 месяца назад
is it possible to reuse the hot water coming out for other purposes like toilet flush/washing machine?
@stevewayne3676
@stevewayne3676 2 месяца назад
Tell the truth you let the freon out into the air 😂
@deenamat439
@deenamat439 2 месяца назад
what about 6 ?
@jackwelch9713
@jackwelch9713 2 месяца назад
can I have one of those chemically soaked oranges please? good lord
@khalid4715
@khalid4715 3 месяца назад
very cool concept of water cooled ACs
@bas4291
@bas4291 3 месяца назад
hope you weren't the installer?
@savannamc407
@savannamc407 3 месяца назад
Didn't get c1, only thing that showed up was rd, HELP
@orfatron
@orfatron 3 месяца назад
Yeah the video failed to mention each manufacturer sets the controler differently. Press and hold longer and enter access code 22. Then find C1 . Hope this is helpful. You can also find the chart symbols online easily .
@savannamc407
@savannamc407 2 месяца назад
@@orfatron thank you
@craigmarshall40
@craigmarshall40 3 месяца назад
Nice work
@Dawn-di1qs
@Dawn-di1qs 4 месяца назад
I would remove the entire EVAP coils and take outside to clean.. then completely let it sun dry.. Same with the fans... remove , take outside to clean.
@fotismil8810
@fotismil8810 4 месяца назад
Mistakes friend,first defrost the evaporator,the valve allready is working low superheated and liquid is flooding in compresor.You "fixed it the opposite way",you destroyed it...haha
@rayclark7763
@rayclark7763 5 месяцев назад
Ty
@user-yz6cv7ob1i
@user-yz6cv7ob1i 5 месяцев назад
Stop using trash
@JuanGarcia-tg1iu
@JuanGarcia-tg1iu 5 месяцев назад
How did you miss that pinched off liquid line at the bottom flare nut on the Txv valve?
@brandone6252
@brandone6252 6 месяцев назад
I have a true drink cooler it was freezing the drinks no matter the setting it was on I replaced with a new thermostat off eBay and it will not cool below 50 degrees 831932 part number idk if you have any idea thank you
@dnoorian
@dnoorian 6 месяцев назад
Depends on the model of the true cooler you have. Each true equipment has a different type of thermostat. Call true mfg and they will give you the correct part number, then you can buy off www.partstown.com
@fandf1449
@fandf1449 6 месяцев назад
Will there be a video showing how freon is pumped into the receiver when the filter on the refrigerator is changed? Greeting
@Valerian-nb5wu
@Valerian-nb5wu 6 месяцев назад
Where is your BEARD NET? That's a GMP VIOLATION.
@wesstevens7133
@wesstevens7133 6 месяцев назад
You are using more refrigerant to cool the water in an exterior motion, and a pump which uses electricity to pump the water that the condenser is submerged in to merely achieve greater results all legal
@wesstevens7133
@wesstevens7133 6 месяцев назад
All you must do is put the coil submerged in water, circulate the water with the pump to a reservoir of cold or water, using the same principle of AC to cool the condensing unit in no time the transfer of heat will be much greater
@user-tq3mg8gr1j
@user-tq3mg8gr1j 7 месяцев назад
I have a 115 volt walk in cooler. The compressor has a start and run capacitor. Would a 3n1 work on this application?
@thescurry
@thescurry 7 месяцев назад
DO NOT follow this guys steps, he did it the incorrect way. 🤦🏻‍♂️
@Speedy3909-Trenchmob
@Speedy3909-Trenchmob 7 месяцев назад
Great information, thanks 👌
@Speedy3909-Trenchmob
@Speedy3909-Trenchmob 7 месяцев назад
Where do you get your stickers made and what software do you use to stay organized?
@DarryllShake-pu7fm
@DarryllShake-pu7fm 7 месяцев назад
you idiot the cam was on fire 😂😂😂😂
@ricksilva3225
@ricksilva3225 7 месяцев назад
Could not see any work being done
@davidflores5761
@davidflores5761 8 месяцев назад
Hello partner on duty! A got some kind of troubleshooting this type of problems... This time was a low ppressure in liquid line just afte filter drier (160psi) and quite good pressure in low side after evap n Comp rotalock (18-20psi) for a 404a walking in freezer meat storage. Txv and beyond still froozen. Sight glass is clear most the time then just flush ... I know is full, Maybe refull of refrigerante the entire system. Good both sides vents, cond-evap were washed. Help me, dont wanna loose this client😢
@davidflores5761
@davidflores5761 8 месяцев назад
There's no label about Oz or Kg to charge the Unit :/
@user-sp3fe4wf8x
@user-sp3fe4wf8x 8 месяцев назад
But this is absolute rubbish for repairing household refrigerators. I have been professionally repairing household appliances for more than 20 years. I have tried various seals from time to time. None of them give a significant result.
@giorgosktoridis903
@giorgosktoridis903 8 месяцев назад
Why you have to adjust the txv if it was working properly before?looking at your suction pressure and considering that the evap coil have some ice i assume you have overcharged the system.Also you dont measure superheat without cleaning the ice of the evap coil first
@ElRudy2006
@ElRudy2006 8 месяцев назад
I have one similar. I plug it in and does not come on. The only noise is from the Omron GL7, the only clicks as i plug the unit. PLEASE HELP..
@josephparaskevas7375
@josephparaskevas7375 9 месяцев назад
Hookup the water to closed loop geothermal.
@alexherrera1208
@alexherrera1208 9 месяцев назад
is call omega clip 2 plastic spacer, square washer then the bracket and finish with the star washer and the final screw
@Garry90
@Garry90 9 месяцев назад
Thank you for your video, got one of these and trying to figure out how to fix the gaps.
@lulubliz6405
@lulubliz6405 9 месяцев назад
Terrible video...not worth watching!!
@stevevelasquez3308
@stevevelasquez3308 9 месяцев назад
How do you clear a cl alarm ?
@hotfeva9843
@hotfeva9843 10 месяцев назад
Just barefaced it huh bruh
@user-ql4ps4vr9v
@user-ql4ps4vr9v 10 месяцев назад
it would have been a great video if you show the controller rather than your face , we could not see what you were doing
@johnkassitas4792
@johnkassitas4792 10 месяцев назад
You should always check power hot to natural instead of ground. It possible you lost your ground
@francisobey325
@francisobey325 10 месяцев назад
Good job, pls can have your WhatsApp number
@trevorfernandes5569
@trevorfernandes5569 11 месяцев назад
Is the door heater connected with the compressor… is it ON all the time or only works during defrost?
@AbidHussain-iy7jz
@AbidHussain-iy7jz 11 месяцев назад
Man, seems like you need some professional help.
@jesseguerra3734
@jesseguerra3734 Год назад
How do you get that unit off the refrigerator?
@howardtoob
@howardtoob Год назад
I love it when someone is doing a repair, for the first time, and makes an, "expert" video. Some people love them some them.
@skullcrusher8589
@skullcrusher8589 Год назад
....and if that doesn't help....?!? Bridge was near ½" on Default-setting. Moving it to the right, decreased it to about ¼"....but still too thick......