Zen HVAC is dedicated to providing HVAC Service Technicians with the information they need to get the job done. Our HVAC Troubleshooting videos are short, to the point and only give you what you need to get your customers HVAC system running. We cover everything; heat pumps, chillers, water pumps, hot water and steam boilers, rooftop units, SWUDs, humidifiers, to....you get the point, we cover it ALL! We also cover every HVAC application; residential, commercial, industrial, manufacturing, mission critical...everything.
Why are we better than the others? Simple; We've been troubleshooting HVAC equipment for over 35 years. We were technicians, technical trainers, and manufacture's technical field engineers. We're also fast, our videos are under 6 minutes long. And, we add a little humor just to lighten the mood!
Common Comfort Compromisers
2:23
3 года назад
Zen HVAC Introduction
1:23
3 года назад
Service with a Smile
1:39
4 года назад
HVAC Business Consultant
1:50
4 года назад
Measure a Milliamp Signals
3:22
5 лет назад
Symptoms of Incorrect Air Flow
4:54
6 лет назад
Calculating RTU airflow
4:46
6 лет назад
Комментарии
@hoozdis
@hoozdis 5 месяцев назад
wow! they editied out the snarky comment regarding sheave measuring! please add it back
@user-ik6nn4yd3r
@user-ik6nn4yd3r 5 месяцев назад
I would like to see a video on why heat pumps have issues heating when all temps and pressures are normal , but not heat from indoor evaporator head
@user-ik6nn4yd3r
@user-ik6nn4yd3r 5 месяцев назад
You should make a troubleshooting hard copy publication for heat pumps and sell it, i would buy it without thinking twice
@patrickcarroll8247
@patrickcarroll8247 7 месяцев назад
Love your video. Explains a lot on the pump curve.
@vladimirodessitt7807
@vladimirodessitt7807 7 месяцев назад
I have a problem, the roofing unit. I turn on cooling mode, cool work properly, then I turn on heat mode I reading my gauge , and I see 0 psi , compressor noise I shut off disconnect, i think problem it’s valve his stock ,maybei not right?
@kirkpeterson1657
@kirkpeterson1657 6 месяцев назад
is the suction 0 psi, or the discharge?
@victorvasquez5418
@victorvasquez5418 8 месяцев назад
Good job thank you for your help
@jrh86
@jrh86 9 месяцев назад
Excellent video exeptional thank you from 🇬🇧 and 🇨🇦
@jrh86
@jrh86 9 месяцев назад
Excellent and thank you for a very interesting informative and professional video.
@kirkpeterson1657
@kirkpeterson1657 6 месяцев назад
Thank You!
@0670kitty
@0670kitty 10 месяцев назад
I bought a new LG window ac 110 volts 7000 btu , after installation when I turn the ac on and put on the heat mode it blow only warm air but not hot , please advise.
@jrh86
@jrh86 Год назад
Excellent explanation and video.
@pointedspider
@pointedspider Год назад
I have a trane that is pulling in to vacuum in AC mode. Works fine in heat. Changed indoor TXV and still doing it. Thinking it's the reversing valve
@tahirif1138
@tahirif1138 Год назад
what if you dont have a gauge on the pump? can you calculate it using length of pipe and elevations at suction and discharge?
@kirkpeterson1657
@kirkpeterson1657 6 месяцев назад
You need actual pump pressure to plot the curve.
@stlbrian33
@stlbrian33 Год назад
Great video. Thanks.
@kirkpeterson1657
@kirkpeterson1657 6 месяцев назад
Thank you!
@mahanteshkedache393
@mahanteshkedache393 Год назад
Excellent
@laworder6092
@laworder6092 Год назад
This is what I was looking for longtime and I found it thanks sir great explanation straight forward. Please could make video on NPSHr & NPSHa checking and calculation
@vnesmuonnam
@vnesmuonnam Год назад
Thank you
@driftless1870
@driftless1870 Год назад
Phenomenal! Thank you.
@JohnnyJr396
@JohnnyJr396 Год назад
Thank you. If I wanted to see what I’m actually pumping compared to a pump curve do I just take the head pressure?
@soloch69
@soloch69 Год назад
Great video thank you for the great info keep them coming happy new year 🎆
@rahulmaske2057
@rahulmaske2057 Год назад
How to check pump running as per pump performance curve.. How to check head flow pressure
@zacharydavis4398
@zacharydavis4398 Год назад
Thanks for spending the time to create and share this content
@jrfrost2254
@jrfrost2254 Год назад
Math error? Isn't the midpoint of a 4-20mA signal 12mA and 8mA (as presented). Determine Span (upper bound minus lower bound): 20 - 4 = 16 Midpoint of the range (half the span): 16 / 2 = 8 Determine Midpoint (add half the span to lower bound): 4 + 8 = 12 Or, average 20mA & 4mA and get 12mA Everything else is good.
@billwittman0504
@billwittman0504 Год назад
I also caught that as well. Thanks
@dennismejia2051
@dennismejia2051 Год назад
Hello, can you please provide any recommended kit to do this?
@SuperGone1
@SuperGone1 2 года назад
Hi, my section line in the heat pump get hot., when it on cooling mode. It was working find the day before. How can fix it thus issue any tips.
@mohammedasifali3891
@mohammedasifali3891 2 года назад
Sir I have a question, if it is a closed loop like Chilled Water Piping. The system shows a suction and discharge pressure while it is running. If we want to know the pump head(in feet)do we have to subtract Suction from Discharge Pressure(in PSI) and multiply by 2.31, please clarify thanks
@rahimys6135
@rahimys6135 2 года назад
Does it need to divide the specific gravity?
@rahimys6135
@rahimys6135 2 года назад
For psi (head in feet) pressure x 2.31/specific gravity
@fengfu2330
@fengfu2330 2 года назад
And have problem understand your definition of compressor line and suction line, very confusing
@fengfu2330
@fengfu2330 2 года назад
Not sure what unit when you talking about 4 degrees, is it F or C?
@ariefsyahrizal3645
@ariefsyahrizal3645 2 года назад
wht about the propeller size ? Does propeller diameter affect the airflows? Suppose I calculated on how much airflows (m³/s) is needed to cool down a certain system, for example a generator. Now how to select a fan out from it ? The rpm of the fan depends on the rotations of the rotor since it'll be installed on the rotor. How to calculate the proper size of the fan to make this schematic works ?
@michaelchavez8466
@michaelchavez8466 2 года назад
Forgot to mention if your calculating feet of head accurately pump has to be running at 60htz
@ehsan3261
@ehsan3261 2 года назад
Hi, thanks for the useful training. For the purpose of my research, I am looking for an equation that I can calculate the air pressure drop due to the existence of heating/cooling coils inside the Air Handling Unit. May you please introduce me such an equation if you are aware of it?
@karangadhvi7
@karangadhvi7 2 года назад
Really appreciate the way of explanation , thanks 😊
@ss4717
@ss4717 2 года назад
ty this was perfect
@wd8557
@wd8557 2 года назад
No new content?
@snipp3t
@snipp3t 2 года назад
What would be the inlet pressure if the pump is sitting open water, such as a submersible pump in a sump?
@yashuarobles7183
@yashuarobles7183 2 года назад
Thanks for sharing it helped me
@chrisnorris1959
@chrisnorris1959 2 года назад
Great stuff! Thank you!
@ZenHVAC
@ZenHVAC 2 года назад
Glad you liked it!
@chrisnorris1959
@chrisnorris1959 2 года назад
Fantastic videos! Instant education I can use in the field tomorrow! Thank you!
@nathandaubis819
@nathandaubis819 2 года назад
NEED TO FIGURE CHILLER APPROACH
@nathandaubis819
@nathandaubis819 2 года назад
A SOLID MOMENT IN HISTORY...NEED TO SEE HOW AIR POCKET AFFECT PUMP FLOW...
@jamessiguenza5721
@jamessiguenza5721 2 года назад
How to do traverse reading
@paullambert1485
@paullambert1485 2 года назад
Good info I have one for u I have a 9000 btu mini split in my bedroom just it's been in there about 2 yrs worked all through the summer I went to turn heat on the unit powers up but the blower or heat does not come on but everything every other mode works what do u think it could be the solenoid not sending power to the Head?
@passiveincome8564
@passiveincome8564 2 года назад
a very nice explanation this air flow calculation. Thanks
@passiveincome8564
@passiveincome8564 2 года назад
1900 cfm / is the chart not starting 5 cFm x 1000? please clear it to me to understand 1900 CFM. thanks
@passiveincome8564
@passiveincome8564 2 года назад
1900 cfm / is the chart not starting 5 cFm x 1000? please clear it to me to understand 1900 CFM. thanks
@amandeepsingh4071
@amandeepsingh4071 3 года назад
I got question for you! I am doing pump curves on new pumps most of the time and actual dead head pressure doesn't match with the given performance curve dead head(curve given by manufacturer)! I checked speed, and impeller size and new pump might not have worn seal or impeller. Is it possible to have air trapped in water system and it will give a wrong reading as air has low density!? its happening a lot! I am really confused and looking for solution to how to find if air in water system? or its something else causing problem! Please help me if you can. Thanks!
@ZenHVAC
@ZenHVAC 3 года назад
You're right, air would skew your readings, but that isn't the culprit if the system has a standing positive pressure and the pump isn't at the high point of the system (the air typically is at the high point/s in the system) Can you give an example suction / discharge readings and the pump data? Also, if the pump has a VFD on it, be sure it's running at 60 hertz.
@ponkrapujari679
@ponkrapujari679 3 года назад
it should be 19000 sir I'm from Mangalore india
@ZenHVAC
@ZenHVAC 3 года назад
You are correct! I miss spoke during the recording.
@ponkrapujari679
@ponkrapujari679 3 года назад
I'm a Hvac designer
@TheSpatulaCity
@TheSpatulaCity 3 года назад
1:08 There's an air handler, No kidding... lol
@hightekinc723
@hightekinc723 3 года назад
Good video!
@ZenHVAC
@ZenHVAC 3 года назад
Thanks!