Do you want to be featured on SGTV? Get in touch with us via social media now!

scolmore.com
Discovering Deco Plus in Matt Black 😍
0:50
19 часов назад
Comprehensive Wiring Accessories - By Click
2:05
3 месяца назад
Welcome to 60 Second Favourites 🪄
0:51
4 месяца назад
Discuss 0, 1 & 2 Medical Locations with us!
4:15
5 месяцев назад
From College to Industrial Electrics ⚖️
13:44
6 месяцев назад
Комментарии
@sk3tchimdg3t33
@sk3tchimdg3t33 9 дней назад
not gonna lie love the dedication to safety but i just poke it with a voltstick that does 12-240 volts and happy days
@deang5622
@deang5622 8 дней назад
They have reliability issues. So the fact it doesn't illuminate doesn't guarantee it is safe.
@SamSisson-kv7gd
@SamSisson-kv7gd 10 дней назад
Does it count as safe isolation with a 230v 30amp double ended male cord? Cause the electricity is safely isolated in the cord!
@simoninfinityelec
@simoninfinityelec 11 дней назад
These are excellent boards! I fitted 2 yesterday and was very impressed!!
@ScolmoreGroup
@ScolmoreGroup 11 дней назад
Sounds like you were very busy, but that's what we love to hear! ⚡
@CONductor-h9h
@CONductor-h9h 11 дней назад
Good demonstration of safe isolation. Looking forward to the next one 👍🏼
@ScolmoreGroup
@ScolmoreGroup 11 дней назад
Subscribe for more demo's 😏
@RobGoodman-i8u
@RobGoodman-i8u 12 дней назад
Great to work with an electrician that keeps you safe. Well done 👏
@ScolmoreGroup
@ScolmoreGroup 11 дней назад
We're here for the electricians community! ⚡👊
@Ben-ho1yn
@Ben-ho1yn 9 дней назад
9/10 Scolmore...would have been nice to see testing both side of the switch...whats to say you only tested the switched line side rather than the feed...any one copying/learning from this could make this mistake. Test both sides or show operation of switch and retest.
@ScolmoreGroup
@ScolmoreGroup 8 дней назад
@@Ben-ho1yn Nice spot 👏
@jakegreen6309
@jakegreen6309 12 дней назад
Great initiative guys 👍🏻
@ScolmoreGroup
@ScolmoreGroup 11 дней назад
#Safe4September 👏
@electricianincorby
@electricianincorby 12 дней назад
Great content! Safe Isolation is a must that most forget!
@marcusbarritt91
@marcusbarritt91 12 дней назад
#safe4september
@anthonybragg
@anthonybragg Месяц назад
When I started you had the YTS scheme where you went to college one day a week and the other four days you were on a placement with an electrical contractor. you were not employed by the contractor and you were paid by the YTS (and I think the electrical contractor was paid a bit for training you) In most cases I know that after your time came to an end the company would take you on if they could. The problem I hear a lot is not being able to get apprenticeships and as said going to college full-time or day release and then a part-time job. After they have done the formal qualifications then calling themselves an improver and go from job to job via agencies. There doesn't seem to be a lot of structured practical learning on the job
@electrician247
@electrician247 Месяц назад
Interesting conversation. This is among the reasons Apprentice 121 exists. Now working in the industry of things and among grass roots week to week. Nearly 5 years, over 7000 into employed trainee positions, 100k plus of support to training providers and lots more. Was always my hope others in industry would start to do more.
@sergiofernandez3725
@sergiofernandez3725 Месяц назад
The IR test is also worth doing to test the cable for possible manufacturer defects. Apparently there is a lot of poor quality cable or fake cable out there. I think Aaron Walstow at Doncaster Cables done a youtube video on it with Gaz from eFIXX.
@Weaselspleen75
@Weaselspleen75 2 месяца назад
One disadvantage of a radial i can think of would be loss of cpc near the circuit start- all sockets and connected loads beyond lose their earth and the customer wouldn't know. Another disadvantage is the need for bigger boards. I wired my new kitchen in a 4mm ring on a 32a rcbo, The thinking behind it for me was any loss in ring continuity wouldn't be an issue as the cable is big enough for a 32amp device where as a 2.5mm ring isn't when a break occurs. also i could get a really long ring and just have one rcbo saving space.
@alessiadipalma3196
@alessiadipalma3196 2 месяца назад
In the practice where I worked, they installed the monitor but it's blank when the outside end rings so we can't actually see the person ringing. Also the exit button doesn't open the door at all. Is there something we are missing? Thanks
@JMKnoetze
@JMKnoetze 2 месяца назад
Yes would have sufficed
@_mackenziie
@_mackenziie 3 месяца назад
My AM2 is a week today, I'm one of the people who just ticked 'i am confident' on every box just to try to pass the AM2. If I don't go in for the AM2 i'll stay at the current job where I dont get the opportunities to practice on things im not too confident on as I can't find any other job as every where want qualified sparks - its a catch 22 really, hopefully i pass on monday
@ScolmoreGroup
@ScolmoreGroup 3 месяца назад
Good luck! I'm sure you'll smash it 👍
@jamesself6449
@jamesself6449 3 месяца назад
8:38 - POAG quantities for Group 1 and 2 locations stated the wrong way round. Group 1 is 1 per patient location, Group 2 is min of 4 and not less than 25%
@craiginboro679
@craiginboro679 3 месяца назад
The reason why we switched from Radial to Ring was it used less wire and has less connections in the FB. Now manufacturers want to sell you bigger FB/CU and more wire. Regards cable sizes, sparkies have always used oversized cables because they can't do the maths. You can run an electric shower off 2.5mm with no more overheating than you can detect in a kettle lead.
@AdamJohnson-gy5we
@AdamJohnson-gy5we 3 месяца назад
Can this exact system be connected to your mobile phone in anyway ?
@ScolmoreGroup
@ScolmoreGroup 3 месяца назад
The Aperta IP systems can connect to your phone via the Click Smart+ app. Apple: apps.apple.com/gb/app/click-smart/id1530163827 Android: play.google.com/store/apps/details?id=com.clicksmart.plus&hl=en_GB
@waynemcmanus2837
@waynemcmanus2837 3 месяца назад
Screwed terminals ! No thanks
@parkercamarillo2460
@parkercamarillo2460 3 месяца назад
No
@jasonmaguire9425
@jasonmaguire9425 4 месяца назад
I trained in France where it is all radial and dual pole breakers. Ring circuits with 32 amp breakers sounds like a recipe for disaster. Way to high with much potential to go wrong. Keep the breaking points low and the amount of sockets on each circuit defined. Simple and safe. Not perfect but compared to ring mains....?
@station-7
@station-7 4 месяца назад
And yet no one’s dying from these dangerous ring mains in their houses after a century of living with them.
@jasonmaguire9425
@jasonmaguire9425 3 месяца назад
@@station-7 actually they do. There are house fires. Most are probably saved by the fuse in the plug which you don't need in radial circuits when designed correctly. The reason you need a fuse is because 32A is way too high for domestic appliances that aren't in the kitchen. The 32A breaker isn't going to break is it!? Why does the rest of the world use radial circuits? Remember the ring circuit was brought in only because resources were scant and not as a system with the most safety in mind.
@MiguelMadrigal-c8k
@MiguelMadrigal-c8k 4 месяца назад
I every where of rhe world the contractors hiring operatives with not care about the certification.. some ones with lots of struggles get certification , this is an umblance mindset. I borne as Electrician at 10 years once I got my university Electrician degree ontherones without qualifation took my post, same here , I got my C&G eelctrical qualification to get a job and another one with CSCS card is hired intead one who has ECS card.every time When I see my diplomas hanging on the wall , I thing are just a frustrated dream.
@sergiofernandez3725
@sergiofernandez3725 4 месяца назад
Some DSO/DNO say 2.5 meter max. Then it's time for. Kvm
@HeathenGeek
@HeathenGeek 5 месяцев назад
I'm surprised LED bulkhead lights haven't been banned from being installed on vertical walls. The glare is blinding for a light that was intended to be fitted on ceilings.
@sergiofernandez3725
@sergiofernandez3725 5 месяцев назад
If you send me 7 of them i will fit in my bathroom
@angelofranklin1
@angelofranklin1 6 месяцев назад
Most if not all countries use radial and not ring. The danger of the ring is heavy louds are plugged in inadvertently at the origin or near origin of the ring the cable can easily be overloaded due to most of the current taking the shortest route back to the distribution board
@tonywatson1412
@tonywatson1412 6 месяцев назад
Design and placing of end of radial socket could be taken into account. vis a vie overloading....and if it could.. maybe be a biggish load .. dedicated circuit ?
@craigharvey17
@craigharvey17 6 месяцев назад
The customer owns the meter tails from the meter to the consumer unit. The dno doesn't care what size they are, it could be a bit of string and they wouldn't want anything to do with it. The section from cut out to the meter is theirs, and they rarely upgrade that either. I've fitted ev chargers where there are 16mm tails in place, they've upgraded the fuse to 100a and left their 16mm in place.
@BobBenz55
@BobBenz55 6 месяцев назад
Interesting 4mm cable in radial … 👍🏼 rewired my house using the ring main method as I was advised that option.
@Cornz38
@Cornz38 6 месяцев назад
My house is fed by overhead cables, one of which is at least 10 meters long as it goes to my neighbours house. They break their own rules. My meter tails are over 4 meters long and have been for over 20 years.
@adriatikkrasniqi1453
@adriatikkrasniqi1453 6 месяцев назад
I love this Regulation as a standard and if is interpreted correctly like you did here nice video 👍
@ningis21
@ningis21 6 месяцев назад
Instead of the switch you show in the video....could I use a time delayed RCD or even a RCBO in its own enclosure as a switch as it also provides greater fault protection and faster disconnection speed of my longer tails?
@ScolmoreGroup
@ScolmoreGroup 5 месяцев назад
There would be no reason why an RCD or RCBO could not be used for overload fault protection. If it was tails that were going to be used as opposed to SWA and they were going to be exposed, then there would be the need for mechanical protection that would come in the form of an RCD / RCBO 😄
@UriahStuff
@UriahStuff 7 месяцев назад
Do these come in male?
@ScolmoreGroup
@ScolmoreGroup 7 месяцев назад
Hi, we have C13, C14, C19, and C20 connectors that can lock into place in any standard outlet: www.ieclock.com/
@erelpc
@erelpc 7 месяцев назад
1:47 How do you do the AM2 without an NVQ? I thought AM2 is the final unit in the NVQ when everything else is complete?
@ScolmoreGroup
@ScolmoreGroup 7 месяцев назад
It depends on the training providers- you could be entered during the final stages of an NVQ, but you would complete the portfolio while waiting to undertake the assessment. It is recommended to complete an NVQ portfolio first.
@williamlowther7051
@williamlowther7051 7 месяцев назад
Love the way electricians say, ring final or even ring final circuit but never radial final or radial final circuit, they are both final circuits you idiots
@mattburch8342
@mattburch8342 8 месяцев назад
Top man clay
@sergiofernandez3725
@sergiofernandez3725 8 месяцев назад
Good stuff guys. Would be nice to see how an adult would change career or retrain to become an Electrician.
@ScolmoreGroup
@ScolmoreGroup 8 месяцев назад
Thanks ☺ We have a few videos that might help with what you're looking for: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-VH65PlsdtVE.htmlsi=6pJJm3Xtdw6-XB_c ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-G8NCYQiykx8.htmlsi=Xj6mnty768hpKzXc ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-1OqSTGQJnMs.htmlsi=DBQVghZlENoulHC3
@Pete197
@Pete197 9 месяцев назад
Thanks too guys. Do you think at 53 I’m too old to start to learn.
@ScolmoreGroup
@ScolmoreGroup 9 месяцев назад
Never too old to try something new or follow a dream!
@tonysoprano9370
@tonysoprano9370 9 месяцев назад
The colleges need to do a better job of telling lads that they need to get the portfolio and AM2 done after the level 3. Ive spoken to people who are telling me they are a spark with just a level 2 and 3 and the colleges have told them this
@sergiofernandez3725
@sergiofernandez3725 9 месяцев назад
Good stuff
@ChrisReed-g6q
@ChrisReed-g6q 10 месяцев назад
You tend to see them in the adjacent corridors. Usually right by the main doors to a corridor 🤣🤣
@ScolmoreGroup
@ScolmoreGroup 10 месяцев назад
Yes, this is the typical application ⚡️
@trawsoza2926
@trawsoza2926 10 месяцев назад
Ive been thinking about it. Ive thought about becoming an electrician and im 32. Awesome video
@ScolmoreGroup
@ScolmoreGroup 10 месяцев назад
There’s never a bad time to follow a dream! ⚡️
@777MrJoe
@777MrJoe 10 месяцев назад
How do I format the internal hard drive, my system can’t seem to find it
@ScolmoreGroup
@ScolmoreGroup 10 месяцев назад
Hi Joe, thank you for your comment! If you contact our ESP technical team directly at technical@espuk.com they will be able to help you with your enquiry :)
@WarrensRandomAndWeirdVideos
@WarrensRandomAndWeirdVideos 11 месяцев назад
Nice one
@andrewforsyth4799
@andrewforsyth4799 11 месяцев назад
Thanks very informative
@sergiofernandez3725
@sergiofernandez3725 Год назад
Impressive stuff. Do you have Wifi extenders in any of them?
@ScolmoreGroup
@ScolmoreGroup 11 месяцев назад
Hi, these are just type A and C USB sockets, but we will pass your feedback on to the product team for consideration 😊
@sergiofernandez3725
@sergiofernandez3725 Год назад
Nice.
@sergiofernandez3725
@sergiofernandez3725 Год назад
Looks good
@ScolmoreGroup
@ScolmoreGroup Год назад
Thanks 😊
@alanwalton5735
@alanwalton5735 Год назад
7:34 when do you think that all outdoor power. Comes along with EV chargers and have automatic disconnection of all live conductors and the CPC.? RCDs started for sockets. where tools could be outside. Now we have all sockets and lights connected to RCDs.
@sibomb3423
@sibomb3423 Год назад
Split boards 🤢