Our Process Automation Division is the market leader for intrinsically safe components & products for hazardous area applications. Complete system solutions- including remote I/O, HART, purging & pressurization, level sensing, corrosion detection, HMI and visualization, Industrial PCs, power supplies, signal conditioning & fieldbus interface products are available.
thx a lot for the video , it is great. i got a question that i have got the same configuration you have with NAMUR normally closed , and i would like to send a normally open logic signal to plc when target is detected , could you please share with me the way of doing this. many thx
Hello @hightechplatform1874, first you need to select the correct intrinsic safety barrier for your application. This would fall under our “Switch Amplifiers” on our website. We have many models to choose from. One deciding factor is the switching frequency. For switching applications with a frequency of 10 Hz or less, you can use a switch amplifier with a relay output. The most common is the KCD2-SR-EX1 for one channel or the KCD2-SR-EX2 for two channels. For switching applications with more than 10 Hz, you should choose a barrier with a transistor output. The most common would be the KCD2-SOT-EX1 for one channel or the KCD2-SOT-EX2 for two channels. All of the above models have DIP switches on the front panel of the barrier that allow the user to select an output mode based on the NAMUR input state. There is also a yellow status LED that illuminates when the output is in an “on” state. This provides a visual indication when the output is “on” based on the position of the DIP switches. For more information, please refer to the datasheet which can be downloaded from files.pepperl-fuchs.com/webcat/navi/productInfo/pds/70109406_eng.pdf?v=20240919144052. We hope this has answered your question.
On Startup it seems to run through a setup mode as opposed to directly purging. would be nice to have a video on purge parameters, timers, and I/O settings
Hello. I wish you a good day. I would like you to help with my issue. I have forgotten the password and username to access the configuration of the Safe Screen of AsiMon3 software. Do you have a way to reset the password to the default one set by the manufacturer? I hope to receive your support. Thank you very much.
Hello @minhanh5580, the only way to reset the safety monitor to the default password is to load a blank project to the controller. There is a better way. When you run the ASIMON software you will get a release code. Call Pepperl+Fuchs 330 486 0001 with this release code and we will give you a temporary password. This temp password will allow you to change the password to whatever one you want. We hope this is helpful to you.
@@PepperlFuchsUSA I'm sorry I didn't clarify the content. I forgot the password for the AS-Interface Safety Monitor. I'm connecting with the Asimon 3 software but cannot access the AS-Interface Safety Monitor. It requires a password, but I don't remember the password or the ID. I would greatly appreciate your assistance.
Hello @amolmeshram7777, the model number of the Weld Tip Sensor is WTS10. If you search WTS10 on the Pepperl+Fuchs website (www.pepperl-fuchs.com/usa/en/index.htm), you’ll find all models associated with this family. We hope this was helpful to you.
Hello. Sir, I want to connect my computer to a safety monitor with the same product code as your video. What type of cable do I need to use to connect? I tried the cat6 rj45 cable but it doesn't connect to the software
Thanks for your question. We offer the cables that will assist you in replacing the AS-Interface safety monitor. It is PN 115088 VAZ-SIMON-RJ45. Please get in touch with our customer service if you’d like to place an order.
Hello Minhanh5580, We're here to help. Our customer service agents and technical support specialists are ready to answer your questions and help you get the information you need. Please fill out our Ask an Expert form by clicking this link here: www.pepperl-fuchs.com/singapore/zh/ask_an_expert_fa.htm
Hi - i require a galvanic barrier for a 24a DC fire alarm detection circuit AND a 24v DC Fire Alarm sounder circuit that uses reverse voltage monitoring. Is there a barrier for these types of uses?
@MW-L.o.S-Essex, thank you for your interest in Pepperl+Fuchs products. We're here to help. Our customer service agents and technical support specialists are ready to answer your questions and help you get the information you need. Please fill out our Ask an Expert form by clicking this link here: www.pepperl-fuchs.com/usa/en/ask_an_expert_pa.htm
Please tell me More about pepper+fuchs products If I can get a video regarding a proper explanation on its terminals functionality and how to troubleshoot it... Many Thanks 🙏
Hello Victoremmanuel711, we will look into your suggestion when creating our next video. If you have any questions you need answered now, you can fill out our Ask An Expert online form, and one of our tech specialists will reach out to you. www.pepperl-fuchs.com/usa/en/ask_an_expert_pa.htm
Hi sir, We are using ENA58IL-S06SA5-1416B17-ABP We use profinet to connect encoder with Siemens PLC S71200. We receive only 255 pulse per revolution , need your support regarding this since this resolution is 65536 ppr.
@allofsexy, this is audio only no video to see, you may also want to listen here: music.ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-9QLoI0gsIZU.html Thank you.
Hi sreevatsa g s, at this time we only have redundancy with the CANopen communication protocol. We do not yet have an SSI version. We hope this answers your question.
@@sreevatsags4328 Hello sreevatsa g s, we will not be launching an SSI model in the near future, but would like to learn more about the application. Please contact us at ask@us.pepperl-fuchs.com to discuss the opportunity.
is it possible to connect 2 UHF RFID with one 4head ethernet controller In first UHF RFID we mapped as 107/157 60 bytes x 4 head with size 60 Now we need to connect the second RFID reader with the 4 head ethernet controller so we need to get size 60 so what mapping address should we give
Hello Roshith cv, with the four-head controller you can connect up to four UHF heads to this controller. You have selected the correct assembly 107/157. This assembly will map 60 bytes for each head for a total size of 240 bytes in and 240 bytes out. The offsets are byte 0 head 1, byte 60 head 2, byte 120 head 3, and byte 180 head 4. If you use the add-on instructions, this offset is automatically taken into account. We hope this is of help.
Sir Good evening sir Alarm showing in the purging control system* When we provide electric power to the whole. When in the purging system showing *Internal purging please wait* after that showing alarm *purging abort lost* after that coming *Full auto mode please wait* Then coming return *Internal purging please wait* This process continues Please help me...
how does the intrinsic module connect with the automation and how does the automaton act? give an example in the event of a flame how it will act?? if there are several photocell sensors. how to connect with the automaton
@eliasboutana3680, we're here to help. Our customer service agents and technical support specialists are ready to answer your questions and help you get the information you need. Please fill out our Ask an Expert form by clicking this link here: www.pepperl-fuchs.com/usa/en/ask_an_expert_fa.htm
Hi there Rashid, typically it’s installation-related and can come from ground loops, poor cable installation (running fieldbus cables next to high-voltage cables), or using improper cable types, variable frequency drives, motors or generators in close proximity to fieldbus devices, and a handful of other things. However, one of the benefits of a FOUNDATION Fieldbus type installation is the variety of diagnostic tools available to help troubleshoot and detect these types of fault conditions, as well as assist in troubleshooting poor quality signals and other physical layer fault conditions. Please feel free to contact us at www.pepperl-fuchs.com/usa/en/ask_an_expert_pa.htm if you require further assistance. Thank you.
Hello @FbrDiego, we're here to help. Our customer service agents and technical support specialists are ready to answer your questions and help you get the information you need. Please fill out our Ask an Expert form by clicking this link here: www.pepperl-fuchs.com/usa/en/ask_an_expert_fa.htm
Amazing! I am just working in a company that uses AS-i for most of the automated system. integrated with the PLC and SCADA system. I have so many doubts but this video clarified very much. Thanks.
Hello Shahyan, thanks for the demo Video KE5, I´m working in a project G20 io-link. I could see you have the project node-red. you can share the nodered project with me. jlopez Spain P+F
Hello Alsahib, so that we can best help you with your application, please contact our experts by clicking on this link here: www.pepperl-fuchs.com/usa/en/ask_an_expert_pa.htm
Hello Joel, we're here to help. Our customer service agents and technical support specialists are ready to answer your questions and help you get the information you need. Please fill out our Ask an Expert form by clicking this link here: www.pepperl-fuchs.com/usa/en/ask_an_expert_fa.htm
We're here to help. Our customer service agents and technical support specialists are ready to answer your questions and help you get the information you need. Please fill out our Ask an Expert form by clicking this link here: www.pepperl-fuchs.com/usa/en/ask_an_expert_fa.htm
We're here to help. Our customer service agents and technical support specialists are ready to answer your questions and help you get the information you need. Please fill out our Ask an Expert form by clicking this link here: www.pepperl-fuchs.com/usa/en/ask_an_expert_fa.htm
Hi there Khawaja Naeem. You need to use the Ultrasonic sensor UC6000-30GM70-2E2R2-V15 www.pepperl-fuchs.com/usa/en/classid_186.htm?view=productdetails&prodid=51811#software ULTRA-PROG-IR software in order to change those settings. The software can be found on the product page under the software tab. If you don't already have the cable, you will need it in order to interface the sensor with the computer you are using. The cable can be found at the bottom of the “Associated Products” tab. Interface cable UC-PROG-IR-USB www.pepperl-fuchs.com/usa/en/classid_190.htm?view=productdetails&prodid=69497. We hope this helps!
Hi Fionn Ó Muirí. What is the complete part number of the PGV you are using and what interface type (CANopen, RS485) do you have? The models with RS485 interface are the only ones that have the “Position View” tab. With the CANopen you should have the "Image View" tab. When you select the RS485 interface, do you see the "Position View" tab? If not, please fill out our Ask an Expert form here www.pepperl-fuchs.com/usa/en/ask_an_expert_fa.htm Thank you.
What cable has to used to interface PGV100RS-F200-B16-1,5M with the Visual Configurator? I have raised a query on Ask An Expert, but never got a response.
Hello Nishaanth T, Typically, you would use the PCV-KBL-V19-STR-USB cable unit. However, the device you mention has leads as opposed to a connector. You will need to add a connector similar to the 219138 V15S-G-ABG-PG9 to establish a connection. Please let us know if this works. If it doesn’t, don’t hesitate to contact us again. Thank you.
@@PepperlFuchsUSA Got it, thanks. I'll let you know. What is the logic level of CAN signals in this model? Also is there any other medium to get in touch with tech support? Any email helpline with fast response? Ask An Expert doesn't seem to work.
Hello Chetta, I assume that you are looking for a protective laminate for PGV code tape. You can use any of the products listed below with these part numbers. The difference being the width of the material. 275589 PGV25M-CD100-CLEAR 70101776 PGV25M-CD120-CLEAR 296110 PGV25M-CD160-CLEAR We hope this is helpful. If you have further questions, please visit our Ask an Expert page www.pepperl-fuchs.com/usa/en/ask_an_expert_fa.htm. Thank you.
Hello Sivakumar, No paper copy is supplied with the 7500 control unit. Paper copies of the safety manual and the DofC for certification are supplied with the unit. There is a QR code on the certification label of the 7500 control unit that takes you to the manual. You can then download and print it if needed. Manuals are also available on our website. The manual for the 7500 can be found at: www.pepperl-fuchs.com/usa/en/classid_7540.htm?view=productdetails&prodid=121831#documents
Hello Ron, thanks for your videos, I have a question about this encoder and software, do you think is possible copy from encoder ENA42HD to another encoder ENA42HD the same program in a way easy.