======🔴Timestamps🔴========= 00:00:00 - Char/String Data Type in MATLAB 00:00:53 - Length of Char/String Data Type in MATLAB 00:01:12 - Size of Char/String Data Type in MATLAB 00:01:33 - Indexing of Char Data Type in MATLAB 00:01:58 - Lowercase and Uppercase format of Char/String Data Type in MATLAB 00:02:29 - Combination of Char/String Data Type in MATLAB 00:03:22 - Finding Character(s) in Char/String Data Type in MATLAB 00:04:28 - Comparison of Char/String Data Type in MATLAB 00:06:26 - Converting Integer to ASCII Code in MATLAB 00:06:41 - Logical Comparison of Char/String Data Type in MATLAB 00:07:47 - String Data Type in Python 00:08:28 - Length of String Data Type in Python 00:08:40 - Indexing of String Data Type in Python 00:09:49 - Logical Comparison of String Data Type in Python
The error is due to analog sensor. It occurs when the analog sensor is broken down or wire break and the red indicator appears in Ai module. In this application temperature sensor broken down.
======🔴Timestamps🔴========= 00:00:00 - Existence Functions in MATLAB 00:00:50 - Functions in Python (Dot Notation) 00:01:10 - Function Madule Importing in Python 00:02:05 - Display All Functions Related to a Module in Python 00:03:14 - Functions Without Dot Notation in Python 00:04:27 - New Function Definition in MATLAB 00:08:22 - New Function Definition in Python 00:11:20 - Returning Values in Python Functions
Thank you for this explanation, I have a same model screen Not working just showing wight screen and same numbers and same words befor numbers Can you help please . Your WhatsApp number to contact with you Thank you more.
======🔴Timestamps🔴========= 00:00:00 - Python and MATLAB Environments 00:01:08 - Display and Assignments Commands in MATLAB 00:02:44 - Display and Assignments Commands in Python 00:03:18 - Script Environment in MATLAB 00:04:36 - Script Environment in Python 00:05:18 - Statements in Python and MATLAB 00:06:40 - String and Integer Data Types in Python and MATLAB 00:11:03 - Operators in Python and MATLAB
Thank you for the video. I have a MCGS TPC6072TF screen. Can I use the same way to do backup. I can't find any information on TPC6072TF . It looks like there is no model number like that. Thank you very much
You're welcome. Unfortunately, I have not worked with this type of HMI. But, the procedure is the same for all type HMI implemented with USB. You can also use the software to provide backup.
I want to ask, can the PLC power supply module turn on/ON when the module is tested separately from the I/O module? What this means is that it was tested with 220v power in separate conditions
Kubur kubur kubur lukman Hakim and export Muhammad ridhauddin binti roslan Malaysian akademi binaan Malaysian @kedaiju akademi binaan Malaysian akademi binaan Malaysian akademi binaan Malaysian akademi binaan Malaysian akademi binaan Malaysian @kedaiju
Hi sir... superb video. I tried this same practice, upto simulation good. But RT runtime file cant download. It Showing error"Loading will jot be performed because preconditions are not met". What should i do for download the RT file?.. Kindly share your valuable knowledge please. Im waiting for your reply.
Thanks. It was very helpful. I just nedeed to check what HMI panel used in old project but anytime i opened project it was saying to install wincc flexible.
There is no way to know the type of HMI which has been used in project. Probably, the version of wincc flexible which has been used in your project is not the same as the installed version. Install another version of wincc flexible. Use VMware software, it's better. Otherwise, send me the project file to analyze.
Hi, Firstly you should check availability of local modules (DI,DO,AI,AO,...) or remote i/o units. Then, you should check some things such as power off, mistake hardware configuration, break down of module(s), network problem (interface modules, connectors, cables, switch).
Hi, When the local modules (DI,DO,AI,AO,...) or remote i/o units are not available, the error occur. A lot of problems can be the reason of the error like power off, mistake hardware configuration, break down of module(s), network problem (interface modules, connectors, cables, switch).
To Open and Close ACB, spring should be in charge mode. If the ACB have the charing motor, spring is charged in any case; however, spring should be manually charged in absence of charging motor. you can see the status of spring by spring indicator.
Thank you so much Sir for sharing the knowledge, We kindly need your help We built PLC s7 1200 program along with HMI KTP400 program and saved it as a full project, When we launch Tia 15 and open the HMI project we can not find the screen so we can edit these screens, please help Sir
Hi, I have a question Mr, Do you use some instruction to read information from slave? Can you share this function? Please? Only need this.. I have trying that a lot time... 🙏🙏🙏🙏🙏
Hi The speed reference of drive has been set to AI1 (4-20mA). ABB ACS880 has two Analog Input (AI1 and AI2). It can only use AI1 in "Factory" macro by default. If you want to use other macros or AI2, refer to parameter 96.04 and change it. AI1 is voltage type by default. Refer to P12.15-P12.20 to change it. Moreover, Voltage/Current selection jumpers (J1) for AI1 should be set.