Тёмный
Eberspaecher North America
Eberspaecher North America
Eberspaecher North America
Подписаться
Since 1973, Eberspaecher has brought state-of-the-art German technology to the North American marketplace. Known for our comprehensive range of independent and compact fuel operated heaters we’ve made a name for ourselves in the transportation industry.

Eberspaecher is a family-owned company who is proud of its heritage and proud of the quality products and services they provide globally. The Eberspaecher group specializes in exhaust technology, climate control systems and automotive controls. We recently celebrated the 150 year anniversary worldwide.

As the North American subsidiary of Eberspaecher we will continue to bring you the cutting-edge technology and innovative product lineup you’ve come to rely on. Based on our deep-rooted commitment to customer satisfaction, we look forward to providing you with our 150+ years of expertise, improved global support and a greater investment in research and development that only a company as large as Eberspaecher can provide.
Hydronic AquaSystem Pt 1 | System Overview
6:18
5 месяцев назад
Hydronic AquaSystem Pt 5 | Touchscreen Operation
12:01
5 месяцев назад
Hydronic AquaSystem Pt 6 | Service & Support
7:01
5 месяцев назад
Breezonic AC System w/ Heat Pump Function
0:53
6 месяцев назад
Airtronic AX3 | An Introduction
21:49
Год назад
#EberspaecherRV
1:05
Год назад
Xellstor
1:26
Год назад
Electric Mini Vehicles
1:21
Год назад
EasyStart Pro | Basic Training
1:09:41
2 года назад
Hydronic S3 Heaters | Basic Training
1:17:08
2 года назад
EasyScan Download & Installation
4:36
2 года назад
Комментарии
@poellot
@poellot День назад
At 1:03:00 i cannot read the info on the screen very well. Where can I find this? I have many espar technical manuals but I have not found this page for connecting 2 heaters to 1 easystart pro.
@poellot
@poellot 21 час назад
I found it, incase anyone else Is wondering it is in the" EasyStart Pro - Addendum"
@AnotherBlackGuy100
@AnotherBlackGuy100 2 дня назад
Nothing better than a tutorial from the manufacturer. I'll finally be able to take care of it.
@lenetterose9023
@lenetterose9023 8 дней назад
Code 52?
@dtadventure4x4
@dtadventure4x4 23 дня назад
12V compability?
@nuriisbiyar2758
@nuriisbiyar2758 Месяц назад
Thanks for information
@poellot
@poellot 3 месяца назад
Will it hurt anything to leave the high altitude mode on when not at high altitude? If it just reduces fuel then the heating capacity would be reduced, but if it overspeeds the fan, then shorter fan life would be expected, Can you tell me which it does in the high altitude mode?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
If you are using a Hydronic S3 CS 12 V with EasyStart Pro, the high altitude mode should be manually turned ON for continuous use in altitudes between 1,500 meters (5,000 ft) and 3,000 meters (10,000 ft) and it should be manually turned OFF for continuous use in altitudes below 1,500 meters (5,000 ft). Using the high altitude mode decreases the amount of fuel delivered, so if incorrectly used continuously in lower altitudes it can increase the risk of flame loss when combined with other factors.
@richard9363
@richard9363 3 месяца назад
I have an Airtronic M2 D4L with an Easy Start PRO. Can I control the heat using the yellow wire from the harness and also keep the controller connected? I'm able to get heat when providing 12v+ to the yellow wire, but get an error on the controller screen. H1Restricted- P000130
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
The EasyStart Pro is a CAN-based only controller, so it uses only the blue-red and blue-black wires to communicate with the heater for all functionalities (e.g., to start and stop it, change temperature setpoint, …). Unless you have another analog controller in the circuit (which is providing its own temperature setpoint), I’d advise you not to turn your heater using the yellow wire, but instead control all heater functionalities directly at your EasyStart Pro. If using only the EasyStart Pro (and not the yellow wire) you keep seeing that code P000130, please contact our Technical Support Team at +1 800 387 4800 or email to ca-to-techservices@eberspaecher.com for additional help.
@richard9363
@richard9363 2 месяца назад
@@EberspaecherNorthAmerica is there any way to control the heater remotely ?
@crowlsyung
@crowlsyung 5 месяцев назад
I'm still seeing "no heater" after trying these steps on my new AS3-B2L install. Any support would be very much appreciated.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
Apologies for the tardy response, @crowlsyung... have you managed to fix your issue, or should I pass your request for help along to our tech department?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
Please check this video which may also help you with this issue: CAN BUS Troubleshooting: Installation & Operation (youtube.com). If you’re still having trouble after following the instructions, please contact our Technical Support Team at +1 800 387 4800 or email to ca-to-techservices@eberspaecher.com. Alternatively, take your vehicle to one of our dealers for assistance (www.eberspaecher-dealer-locator.com/).
@livefreevinnie
@livefreevinnie 6 месяцев назад
My Hydronic S3 came with my Storyteller Overland MODE LT need to be serviced at 4,300 hrs. What kit should I use for the rebuilt? Any video on how to rebuilt / service this Hydronic S3?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
Apologies for the tardy response, @livefreevinnie... have you managed to address your issue, or should I pass your request for help along to our tech department?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
Hi Vinnie. This is the answer I bgot back from engineering: Please contact our Technical Support Team at +1 800 387 4800 or email to ca-to-techservices@eberspaecher.com in order to assess the specific needs in your case. Alternatively, take your vehicle to one of our dealers for assistance (www.eberspaecher-dealer-locator.com/).
@cuisinartOH1
@cuisinartOH1 6 месяцев назад
Your website has said availability in early 2024 for nearly a year. Can you provide which month they will be available for after-market purchase? And, will there be limited availability for some time after they hit the market? Thanks!
@eberspaechercom
@eberspaechercom 6 месяцев назад
Good news, it's coming - and quite soon at that. Stay tuned.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
It's looking like it'll be available more like early 2025. I'll make a note to message you again once they've started to be shipped to our dealers. We apologize for the delay and any inconvenience this has caused.
@cuisinartOH1
@cuisinartOH1 3 месяца назад
@@EberspaecherNorthAmerica Thank you for your honesty. I hope you’re ready for volume shipments in early 2025 or you will be at least one year behind the companies early to market - nay, not early as in innovators - but they at least have products in the market.
@mcl237
@mcl237 6 месяцев назад
Awesome video. I thought it was my relay and when I disconnected it I shorted out the fuse. Do you know where it’s at. If I key my ignition it will turn on my controller and allow me to the. On heater but that’s only with the key turned on ACC
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
Apologies for the tardy response, @mcl237... have you managed to address your issue, or should I pass your request for help along to our tech department?
@mcl237
@mcl237 3 месяца назад
@@EberspaecherNorthAmerica got it done
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
We would need further info on your case in order to better assist you, so please contact our Technical Support Team at +1 800 387 4800 or email to ca-to-techservices@eberspaecher.com and they will be happy to guide you on solving this issue. Alternatively, take your vehicle to one of our dealers for assistance (www.eberspaecher-dealer-locator.com/).
@vince9345
@vince9345 6 месяцев назад
Where could I buy a spare termination resistor cap (20.2900.70.0017)? Where is the catalog?
@rewkirsch8557
@rewkirsch8557 6 месяцев назад
any dealer should have them.
@vince9345
@vince9345 6 месяцев назад
@@rewkirsch8557 They should, but they don't (at least where I live)
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
Apologies for the tardy response, @vince9345... have you managed to address your issue, or should I pass your request for help along to our tech department?
@vince9345
@vince9345 3 месяца назад
It wasn't easy but after a few months I finally got it. Thanks
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
Hi Vince. Our engineering team just replied that you SHOULD be able to order this part in any of our dealers (www.eberspaecher-dealer-locator.com/). If you wish to access our Product Catalogue, please follow the instructions given in this video: Where to Find Technical Information, Manuals and Part Numbers (youtube.com). You can also call or email our technical support department directly: Technical Support 📞 1-800-387-4800 X2299 📧 help@eberspaecher.com
@GerardBriaud
@GerardBriaud 6 месяцев назад
Traduction francais
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
Salut Gérard. Je me demandais s'il y avait peut-être une option de sous-titres en français dans le sous-titrage codé ? Dans le cas contraire, je transmettrai vos commentaires et je vous répondrai avec leur réponse. Merci. Votre intérêt pour nos vidéos est grandement apprécié.
@markhopsecger345
@markhopsecger345 7 месяцев назад
I'm having trouble with a AS3-B2L. I have tried to address any metering pump issues nothing done has made improvements. It makes a weird loping sound and flame goes out at times and relights all before reaching set temperature. I have a video of all this I could send to someone.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
Apologies for the tardy response, @markhopsecger345... have you managed to address your issue, or should I pass your request for help along to our tech department?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
We would need further info on your case in order to better assist you, so please contact our Technical Support Team at +1 800 387 4800 X2299 or email to ca-to-techservices@eberspaecher.com and they will be happy to guide you on solving this issue. Alternatively, take your vehicle to one of our dealers for assistance (www.eberspaecher-dealer-locator.com/).
@DouglasCole-r6e
@DouglasCole-r6e 7 месяцев назад
Good, detailed overview! Thanks for posting.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
You're very welcome. Glad you found it useful.
@PainterD54
@PainterD54 8 месяцев назад
No, you don't always have to get new parts. If you use a larger lag screw you can pull the atomizer screen out without damaging it and reuse it if you clean it off. I suggest brake cleaner and a good jet nozzle on your air compressor to blow it clean. If your glow plug still works (you can just check it with 12 volts) you won't need to always order new parts. The same goes with the larger screen at the rear of the larger heat chamber. Keep it clean and your heater will serve you fine.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
The proper service recommendations are the ones given in this video and trying to clean the atomizer screen will not work every time and is not advised. The glow pin does not require to be replaced, unless you break the ceramic element or the wires during removal or reinsertion. The one part you require to purchase for this process is the atomizer screen that comes with the insertion tool to set the proper depth as explained in the video.
@temoaguil1830
@temoaguil1830 8 месяцев назад
thanks very much 👍🏼
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
You're very welcome!
@liveyouradventure6573
@liveyouradventure6573 8 месяцев назад
thank you so much for making this video. It helped me to get my heater working again on a cold night so that I could have a comfortable sleep. It also means I don’t have to worry about something break being broken on my rig and having to pay somebody else to fix it. Thanks again.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 3 месяца назад
You're most welcome. Happy to read our heater is helping you have a better night's sleep.
@bigfootwojak4393
@bigfootwojak4393 8 месяцев назад
Pro tip, jutuse a pick to mash up the screen into a mangled ball, thread a wood screw down into there and pull it it.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Месяц назад
We cannot conform nor deny that this "hack" will work. But thanks, Bigfoot. : )
@michaoksentyuk8839
@michaoksentyuk8839 8 месяцев назад
Thanks for the video, is really needed to be
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 8 месяцев назад
Glad it helped.
@kbwaldron
@kbwaldron 9 месяцев назад
Please note the electrical connector is NOT always the high side. Sometimes it is on the inlet rather than the outlet side. This is the case for the Hydronic S3 supplied fuel pump, part number 22 4550 05. It may be true for others as well. When doing this maintenance make note of the orientation of the existing fuel pump.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 8 месяцев назад
Correct, connector orientation varies for different fuel metering pump styles. Install the fuel pump according to the installation instruction for the specific heater you are installing.
@panchovillaz8004
@panchovillaz8004 9 месяцев назад
I putting in me truck cost me $1000. Little diferent. You program you star driving 4am. You program turn warm 2am. Wen you star good
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 8 месяцев назад
Sorry, not sure if you have a question or if this is just a general comment. : ). If you have a question, happy to try and find you an answer. Kind regards, Eberspaecher Social Team
@rickverwoerd
@rickverwoerd 9 месяцев назад
I was looking for the following error codes and what they mean: P00012a P000126 Where can I find the definitions?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 8 месяцев назад
Hey Rick, I've emailed Tech Support directly and will add their answer as soon as it arrives. Apologies for the tardy response time. Will endeavour to do better. Kind regards, your Eberspaecher Social Team
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 8 месяцев назад
Hey Rick... here's the response I received from Tech Support: The error codes can be found in the repair instruction. Instructions should be made available from wherever you obtained your heater. Alternatively, they can be downloaded from the Partner Portal. Unfortunately these files are too large to send via email. P00012A Unsuccessful start procedure: * Check exhaust and combustion air system. * Check fuel quantity and fuel supply, see page 22. * Renew the fuel filter. * Clean the fuel filter in the connection socket of the metering pump. P000126 Flame cutout within the control range 0% - 25%: * Check exhaust and combustion air system * Check fuel quantity and fuel supply (see page 22) * Check flame sensor, see Fault Code P000120 and Fault Code P000121. Hope this helps.
@rickverwoerd
@rickverwoerd 8 месяцев назад
@@EberspaecherNorthAmerica Well, I have bought the heater as part of a campervan. I was standing in the cold and could not figure out how to start the heater. Having instructions publicly available (and not behind partner page) would be helpfull not? Thanks anyway!
@GerardBriaud
@GerardBriaud 6 месяцев назад
😢​@@EberspaecherNorthAmerica
@Jesustencen
@Jesustencen 10 месяцев назад
Where can I buy this tool?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 9 месяцев назад
Go to the Eberspaecher Dealer Search landing page and find a dealer close to you. www.eberspaecher-dealer-locator.com/
@nikalascross1506
@nikalascross1506 10 месяцев назад
Dr eye 👀 9ette😮😮😢😮
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 8 месяцев назад
??
@bbdgha
@bbdgha 10 месяцев назад
I’m terribly sorry (and embarrassed) that this heater slipped through the cracks but that completely new fan unit probably cost the same as about 3 new Chinese heaters that last for years and years 😂
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 9 месяцев назад
Comment from @douglasharley2440 who bought the Chinese knock-off. Not the edit below. So you jusdt never know, @bbdgha i paid $160, including shipping for an 8kw Chinese diesel heater (included 5l tank), and i've been running it for almost 2 weeks now and I LOVE IT!!! just finished-up my first 5l fill-up of the tank, and it has been effortlessly keeping my tiny home built in a box truck a very comfortable 75-80 degrees in 20-30 degrees weather. i couldn't be happier. EDIT: the thing worked great for 3 weeks and then broke permanently due to crappy wiring. DON'T BUY THE KNOCK-OFF HEATERS, THEY'LL BREAK AND CANNOT BE FIXED.
@bbdgha
@bbdgha 9 месяцев назад
@@EberspaecherNorthAmerica my $160 knock off been running 24/7 New Zealand winter for over 8 years flawlessly now and will tear down this summer to check inside and sling a gasket kit in $1.00, new bearings NMB ZZ625 $3.00. 😂😂😂😂
@Michael-xk7pl
@Michael-xk7pl 10 месяцев назад
How do you update the software like you mentioned?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 9 месяцев назад
Hey Michael. My answer from tech support was “the EasyStart Pro software can be updated using the EasyScan diagnostic tool.” Hope this helps. Happy New Year!
@Urge38
@Urge38 10 месяцев назад
The burn chamber gasket will be cracked, that is normal !!!!!!!! What a joke If the gasket is cracked you will be poisoned You my friend should not be doing videos!!!!
@thisisme4858
@thisisme4858 11 месяцев назад
I have a ebespacher DL1C. Is the dismantling and fitting the same as this model?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 9 месяцев назад
Apologies... I have an email in and will get back to you with an answer asap. Cheers
@wanderingzythophile9083
@wanderingzythophile9083 11 месяцев назад
So does the S3 glow pin not have a screen around it like other diesel-fired heaters? I'm seeing zero references to a screen for this model. Thank you!
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 11 месяцев назад
Hey Wander... straight from the Trainer's keyboard: "The Hydronic S3 does not have an atomizing screen. The combustion chamber and burner assembly has been redesigned." Hope this answers your question.
@wanderingzythophile9083
@wanderingzythophile9083 11 месяцев назад
@@EberspaecherNorthAmerica I left out one detail as I wasn't aware there was an Airtronic model S3 - I'm talking about the hydronic unit here. But - safe bet they share this redesigned assembly? Would make sense. Thank you!
@johnplyler7054
@johnplyler7054 Год назад
I just wish this video (and any others) were noted in my manual!
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 11 месяцев назад
Hi John... that's an excellent idea and I'll be passing your suggestion along. In fact, I think what I'll do is suggest a landing page for each product that has everything a user might need to know, including the manual and any how-to videos we have for the product. And I think the plan, going forward, is to include a QR code that opens up a page like I just described. Thx John.
@markeyelverton
@markeyelverton Год назад
Hi - will this unit work to replace easy start select? Also, does it have built in ambient temperature monitoring?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 11 месяцев назад
Hi Mark... apologies for the tardy reply. I've just emailed the head of technical product support and will get back to you with an answer shortly.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 11 месяцев назад
Okay, Mark... this is the response I receivbed from tech support: The Easy Start Pro does not replace the EasyStart Select directly, the EasyStart Pro is only compatible with the AX2 and AX3 family of air heaters and the HS3 CS family of coolant heaters. It does have built in ambient temperature monitoring, but that is only compatible with an AX2 or AX3 heater. For further questions about the controller or controller replacements please contact our Technical Support Team at CA-TO-TechServices@eberspaecher.com. Hope it answers your question, Mark.
@grahamecalvert1248
@grahamecalvert1248 Год назад
Hi, thanks for a very interesting and informative view of the easy start pro controller.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica 11 месяцев назад
Glad it was helpful, Graham! Let me know if there's any other content you'd like to see as a video and I'll pass your request along.
@OldGamerKatt
@OldGamerKatt Год назад
Great guide except on my controller when I program no1 then move to nu2 , it shuts off nu1. I go back in and turn on nu1 again, it shuts off number 2. I havent even tried to program nu3 yet.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Apologies for the tardy response, Katt. And I'm sorry about your issue. I would suggest you reach out to our Technical Support Team at 1-800-387-4800 X2299 and/or help@eberspaecher.com. They will be more than happy to assist you and/or answer any questions you have. Please don't hesitate to reply to this message if you don't hear back from anyone and I'll personally forward your issue to the support team and make sure you receive a speedy reply/answer.
@harryknutts8428
@harryknutts8428 Год назад
I got a brand new freightliner. I went to turn on the bugs heater for the first time and it says check fuel pump. It’s got to be something simple that I can’t figure it out.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Apologies for the tardy response, Harry. And I'm sorry about your issue. I would suggest you reach out to our Technical Support Team at 1-800-387-4800 X2299 and/or help@eberspaecher.com. They will be more than happy to assist you and/or answer any questions you have. Please don't hesitate to reply to this message if you don't hear back from anyone and I'll personally forward your issue to the support team and make sure you receive a speedy reply/answer.
@игорьчерныш-р7ы
Спасибо помогло если бы комментировал было бы супер !а то надписей не видно считал по счелчкам😅
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Извините, я не уверен, что Google Translate хорошо справился с переводом вашего комментария. Не могли бы вы отправить его еще раз? :)
@johnsuderman3674
@johnsuderman3674 Год назад
Mine shows "no heater" and button is jammmed code. How do I reset/ make it functional again?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Apologies for the tardy response, John. And I'm sorry about your issue. I would suggest you reach out to our Technical Support Team at 1-800-387-4800 X2299 and/or help@eberspaecher.com. They will be more than happy to assist you and/or answer any questions you have. Please don't hesitate to reply to this message if you don't hear back from anyone and I'll personally forward your issue to the support team and make sure you receive a speedy reply/answer.
@joomomma9463
@joomomma9463 Год назад
I work at the st Louis location.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
That's great. I hope you're enjoying your work. How long have you been with the company.
@joomomma9463
@joomomma9463 Год назад
@@EberspaecherNorthAmerica I started in August we are laid off right now though because of the GM automobile strike I started as a temp worker it's a good job gets hot on those summer days pays good so I'm waiting to get called back soon.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Hope you get called back real soon. Good luck!@@joomomma9463
@Robemahiser
@Robemahiser Год назад
I know that voice. Hope all is well!!
@bl1gh7y
@bl1gh7y Год назад
I can’t get our D2 to come out of the 4 minute lock out cycle. It just runs on and on.. I have to unplug the power and leave it for days. Is there any other way to reset it?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Apologies for the tardy response and I'm sorry about your issue. You can contact Technical Support at 1-800-387-4800 X2299 and/or help@eberspaecher.com.
@robertb2468
@robertb2468 Год назад
My temperature is displayed on the right ,like it should. But when I go to set the temp all that appears is minutes for running and no temp adjustment shows up next on the screen when I tun the dial. Can you help me please?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Hi Robert. Apologies for the tardy response and I'm sorry about your issue. You can contact Technical Support at 1-800-387-4800 X2299 and/or help@eberspaecher.com.
@stacypink2103
@stacypink2103 Год назад
Thank you 😊
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
You're welcome 😊
@RayosMcQueen
@RayosMcQueen Год назад
Hello! I have an S3 B4E with numbers 20 2049 and 177467HF. Is this compatible? Will it let me set the room temperature?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Hey Rayos. Apologies for the tardy response and I'm sorry about your issue. You can contact Technical Support at 1-800-387-4800 X2299 and/or help@eberspaecher.com.
@richardanderson7803
@richardanderson7803 Год назад
What a great clear explanation on the operation and setting up of this unit. Thank you so much for this video. What interval ( hrs) should a M2 D4R be serviced at and what does this maintenance consist of
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Hi Richard. I'm glad you liked the video and found it informative. As for answering your question, the best thing would be to contact Technical Support at 1-800-387-4800 X2299 and/or help@eberspaecher.com.
@maxpower2913
@maxpower2913 Год назад
So do you need a separate connection to hook up both Airtronic and Hydronic heaters to one single East start pro? The info is horrible on it and nobody can answer my question.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Hi and my apologies for the tardy response and I'm sorry about your issue. You can contact Technical Support at 1-800-387-4800 X2299 and/or help@eberspaecher.com.
@colejackson9415
@colejackson9415 11 месяцев назад
Did you figure it out? Currently trying to do the same thing…
@maxpower2913
@maxpower2913 11 месяцев назад
Yes it was simple. I just called and ordered the separate cable that is just a daisy chain you add on and plug into the heaters. I forget the part number but they know what you are looking for of you call a dealer
@nuriisbiyar2758
@nuriisbiyar2758 Год назад
Harika
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
LOL... I used Google Translate. Glad you think so. And thanks for commenting. : )
@lucacavallini561
@lucacavallini561 Год назад
I Discover that the heater, startup more Better, if i remove One turn of the layer from the grid atomizer...and this make more Easy remove It in future maintenance
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Happy to hear you found a workaround that works for you, Luca.
@edwardfitzgerald5119
@edwardfitzgerald5119 Год назад
Totally Unreliable.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Hi Edward. We're sorry you had issues with our product. Did you take it back to the dealer? If you don't mind my asking, where did you purchase it. We've had issues with customers buying their heaters online from unauthorized sellers. Just something to keep in mind.
@fabienguillet3513
@fabienguillet3513 Год назад
hi ! can you use tghe easy start pro to control a ventilation unit (like kalori silencio2) linked to the hydronic heater? or do you need to install a separate control unit with a separate room temp sensor?
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Hi Fabien and thank you for your question. According to our engineering depart, unfortunately the answer to your question is no. The EasyStart Pro is a CAN based controller and the ventilation units (like Kalori silencio 2) don’t have CAN communications built in. But I will definitely pass your question / suggestion on to our development team. I'd be surprised if this wasn't something they're already working on. If anything should develop in this area, I'll be sure to let you know about it. Again, your feedback is much appreciated, Fabien.
@misslovell
@misslovell Год назад
What if the vent gets blocked and won't turn on? When this happened, I wasn't with our vehicle, but the 'renters' said they woke up and the heater had shut off. After talking with them, it sounds like a computer bag may have been placed near or in front of the vent.
@EberspaecherNorthAmerica
@EberspaecherNorthAmerica Год назад
Hi Lindsey. Sorry to hear that. I'm not a member of the tech team, but I will email my contact in that department and try to get you an answer asap.
@misslovell
@misslovell 9 месяцев назад
@@EberspaecherNorthAmerica by chance, was there any answer they gave you?