Тёмный
Daniel Holwell
Daniel Holwell
Daniel Holwell
Подписаться
This channel is for plumbing students who are learning Level 2 Plumbing.

Best of luck on your course.
Principles Session 1 Part 1   Electricity
11:33
3 года назад
Principles Session 1 Part 2   Heat
10:30
3 года назад
Session 2 Part 2   Stacks
12:39
3 года назад
3.2 Radiator Valves
11:42
3 года назад
3 1 2 Heat Emitters Part 2
11:35
3 года назад
3.1 1Heat Emitters Part 1
11:09
3 года назад
2.1 Heating Pipes and Components Part 1
14:44
3 года назад
2.4 S and Y Plan Heating Systems
7:51
3 года назад
2.3 One and Two Pipe Heating Systems
5:54
3 года назад
1 5 Boiler Interlock
21:18
3 года назад
Heating 1 4 Hot Water Heating
16:42
3 года назад
Heating 1 3 Intro to Heating
16:44
3 года назад
Комментарии
@Gglov3ls
@Gglov3ls 18 дней назад
W
@user-zl6ox1dg5z
@user-zl6ox1dg5z 27 дней назад
Can’t see half the drawing for your box m8
@EvilBroski
@EvilBroski 2 месяца назад
Thanks for making and sharing these videos. Very helpful for my qualification.
@danielholwell8150
@danielholwell8150 2 месяца назад
Nice one. Glad it’s a help!
@asadshah5637
@asadshah5637 2 месяца назад
Thankyou Dan
@danielholwell8150
@danielholwell8150 2 месяца назад
No worries Asad. I’m glad they’re useful.
@dashawnbrown3725
@dashawnbrown3725 2 месяца назад
W video
@dashawnbrown3725
@dashawnbrown3725 2 месяца назад
w video
@dashawnbrown3725
@dashawnbrown3725 2 месяца назад
W video
@dashawnbrown3725
@dashawnbrown3725 2 месяца назад
w video
@dashawnbrown3725
@dashawnbrown3725 2 месяца назад
w video
@dashawnbrown3725
@dashawnbrown3725 2 месяца назад
W video
@bryandeniega6249
@bryandeniega6249 2 месяца назад
What is the maximum pressure for 1inch diameter potable water pipe sir.?
@danielholwell8150
@danielholwell8150 2 месяца назад
The best source would be the manufacturer as it will vary by material.
@dashawnbrown3725
@dashawnbrown3725 2 месяца назад
W video
@user-wq2vz6wj8f
@user-wq2vz6wj8f 3 месяца назад
Thx. Is it ok to add a pressure tank to the hot water system instead of using an open vent faucet? (i.e. use a regular faucet, but have a pressure tank to prevent steam pressure building up) Thx
@danielholwell8150
@danielholwell8150 3 месяца назад
American building codes are a bit different to the UK Building Regulations (I’m assuming you’re American as you use the term faucet). In the UK you shouldn’t expect any steam as there are a number of safety precautions that should be taken to prevent the water from exceeding 100*C (control stat, overheat stat and temperature/pressure relief valve). In most cases it’s normally okay to upgrade an open vented to sealed system as long as it’s installed to local regulations/code.
@meronachi1863
@meronachi1863 4 месяца назад
Hello mate it's hard to hear you. I think the microphone or something
@danielholwell8150
@danielholwell8150 3 месяца назад
Thanks for the heads up
@42RHD
@42RHD 4 месяца назад
Thank you so much!
@danielholwell8150
@danielholwell8150 3 месяца назад
You're welcome!
@asadshah5637
@asadshah5637 5 месяцев назад
👍
@asadshah5637
@asadshah5637 6 месяцев назад
Thanks Dan
@asadshah5637
@asadshah5637 8 месяцев назад
Thanks
@asadshah5637
@asadshah5637 8 месяцев назад
@asadshah5637
@asadshah5637 8 месяцев назад
Thanks
@asadshah5637
@asadshah5637 8 месяцев назад
Thanks
@asadshah5637
@asadshah5637 8 месяцев назад
Thanks Daniel
@danielholwell8150
@danielholwell8150 8 месяцев назад
No worries. Glad it’s useful.
@zainabalghazaly628
@zainabalghazaly628 8 месяцев назад
valve, mcm bntuk ribbon.. mcm ada storage bom.. fuhs
@ahmedadam1699
@ahmedadam1699 9 месяцев назад
I am still watching videos when need to learn about radiator you student from conel college thank sir Daniel Howell
@HekmatullahRishtin-lr2bx
@HekmatullahRishtin-lr2bx 9 месяцев назад
very helful
@ahmedadam1699
@ahmedadam1699 9 месяцев назад
Thank you Daniel iam do my level But still come back to watch your video
@danielholwell8150
@danielholwell8150 8 месяцев назад
Really glad they’re still of use Ahmed.
@ahmedadam1699
@ahmedadam1699 Год назад
sir Daniel i have watched all your videos through out this year level2 thanks you
@akashshah1907
@akashshah1907 Год назад
Great videos. Where can I download slides of your videos?
@danielholwell8150
@danielholwell8150 8 месяцев назад
They’re on the Moodle page of CONEL College, but not available to the public more generally I’m afraid.
@deanpike6252
@deanpike6252 Год назад
Thank you for the explanation. Is it fairly expensive to upgrade to a two pipe system from a one pipe, especially if you are also upgrading to a combi boiler?
@mileswhite8004
@mileswhite8004 Год назад
Hi Dan, thanks for your vids, they make it much easier to study than just reading through the textbook. At the end of them you say now its time for your tasks.....Where could I find what these tasks are? Are they art of the C&G course or from another institution you worked for?
@danielholwell8150
@danielholwell8150 Год назад
I have them on the Moodle site at the college I work for Miles.
@mileswhite8004
@mileswhite8004 Год назад
Just starting my Level 2 Diploma and very grateful to have found these videos. Thanks.
@TwoTees14
@TwoTees14 Год назад
Hi Daniel, just wanted to say a big thank you for these presentations. In line with the City and Guild slide decks, it helped me to revise in a structured way and get the grade I needed.
@1981shafi
@1981shafi Год назад
Hi Great video. Where can I buy the testing equipment from?
@therealsteaklife70
@therealsteaklife70 Год назад
Dan the man
@trancemadmaz
@trancemadmaz Год назад
Really enjoy watching these slides. Like having another tutor for my level 2 course. Thank you
@boxinggloves1699
@boxinggloves1699 Год назад
Aye
@HUSKY7-1
@HUSKY7-1 Год назад
On a one pipe system with radiators in series, would it be necessary to balance the system via the lock shield valve on each radiator,?
@danielholwell8150
@danielholwell8150 Год назад
Water would only be pumped round the pipe not through the radiators. It travels into/through the radiators via convection and you wouldn't want anything to slow this down, so locksheilds should be fully open. You would need to oversize later radiators to allow for the heat loss from earlier radiators.
@ahmedadam1699
@ahmedadam1699 Год назад
Thank you for your video i am student at conel my level 2 plumbing
@danielholwell8150
@danielholwell8150 Год назад
Glad you enjoyed it Ahmed.
@nirayokifle5323
@nirayokifle5323 Год назад
Excellent explanation
@danielholwell8150
@danielholwell8150 Год назад
Much appreciated.
@hamedyaghoubi4367
@hamedyaghoubi4367 2 года назад
Greate
@sandeepathwal4188
@sandeepathwal4188 2 года назад
Where is the rest
@matthewholmes9986
@matthewholmes9986 2 года назад
Live your videos mate am really grateful for your content i am a 21 year old plumbing improver getting qualified and this really helps me out.
@danielholwell8150
@danielholwell8150 2 года назад
Thanks Matthew. Really appreciate the feedback.
@42RHD
@42RHD 2 года назад
Thank you!
@42RHD
@42RHD 2 года назад
Brilliant! Thank you.
@johngarry1572
@johngarry1572 2 года назад
good work Dan ,im doing my c & g level 2 this year and so far ive got distinctions in my first 3 tests - i have my fourth tomorrow(h & s) and have found your videos and quizzes very helpful!.
@samehlamada6141
@samehlamada6141 2 года назад
well done in explaining, we wishing from you that you explain the most common sanitary pipework used in UK and what is the basic difference of that systems than that used in US and Canada
@danielholwell8150
@danielholwell8150 2 года назад
Thanks Sameh. I think largely the systems are similar given the purpose is the same. There will be a few differences I’m sure, but my channel is for my plumbing students in the UK, so I couldn’t go into specifics. All the best finding what you’re looking for though.
@Derek-ew8zy
@Derek-ew8zy 3 года назад
Hi Daniel, Thanks for this video, it was incredibly useful. where is Part 2?
@danielholwell8150
@danielholwell8150 2 года назад
I'm working on it Part 2 is more about maintaining drainage systems than commissioning.