Тёмный
JR Mayo
JR Mayo
JR Mayo
Подписаться
Hot Gas Defrost
14:04
2 месяца назад
Parallel Rack Series Basic Electrical
8:53
3 месяца назад
Co2 General Rack setup
22:52
4 месяца назад
February 26, 2024
3:26
7 месяцев назад
Tuning a glycol pump station.
3:54
Год назад
August 25, 2022
3:00
2 года назад
Ice Bucket Challenge.
0:47
10 лет назад
How to calibrate transducers
6:18
10 лет назад
VID-20130812-00002
0:17
11 лет назад
How to set a DDR
11:44
11 лет назад
Комментарии
@sotonek
@sotonek 10 дней назад
Great Job!! explained very well.
@NewDestinationEng
@NewDestinationEng 24 дня назад
Is that a critical or subcritical system? I heard critical CO2 runs at ridiculous high pressures
@geoffreyyoung5419
@geoffreyyoung5419 26 дней назад
Love the show
@chuckh.2227
@chuckh.2227 26 дней назад
Very interesting!
@Shawn_RHVAC
@Shawn_RHVAC 29 дней назад
I am looking forward to my racks being converted over to CO2 in the near future!! Training so far has been awesome, it’s the way the future is heading guys! The more you know the more valuable you are in a demanding field of work!!!!!
@Shawn_RHVAC
@Shawn_RHVAC 29 дней назад
Great information
@ThumperKJFK
@ThumperKJFK Месяц назад
@ThumperKJFK
@ThumperKJFK Месяц назад
@henryching3960
@henryching3960 Месяц назад
Thank you that great tour of that equipment.
@kevinoconnor2631
@kevinoconnor2631 Месяц назад
Love this video. I spent 44 years in supermarket refrigeration in the North East. I did mostly start ups and troubleshooting of all the newest racks and retired in 2016 to SC. I worked alot on glycol systems, all have been Hill Phoenix racks. Unfortunately just missed out on CO2. Two years after retiring, Wegmans installed that very Cascade system you have in this video. I constantly keep up with the changes in the business and have even taken online courses in CO2. Please keep up the great vieos and look very much forward to your transcritical rack start up and tour. Thank you.
@CubbyVanLife
@CubbyVanLife 2 месяца назад
Wow you are brilliant! Nice videos.
@TheGhettoLobster
@TheGhettoLobster 2 месяца назад
Thank you
@hvacr_wa4282
@hvacr_wa4282 2 месяца назад
Nice video
@hvacr_wa4282
@hvacr_wa4282 2 месяца назад
Very good videos, keep up the good work!
@TheGhettoLobster
@TheGhettoLobster 2 месяца назад
Great videos. Please make more!
@colejc
@colejc 3 месяца назад
enjoyed the video please continue making them good sir!
@jrmayo_reftech
@jrmayo_reftech 2 месяца назад
Thanks, will do!
@pimp4405
@pimp4405 3 месяца назад
Publix
@shahinhalf4121
@shahinhalf4121 3 месяца назад
Useful tnx for sharing
@jrmayo_reftech
@jrmayo_reftech 2 месяца назад
You’re Welcome
@alimohame4153
@alimohame4153 3 месяца назад
Great
@TheGhettoLobster
@TheGhettoLobster 3 месяца назад
Great channel!!
@jrmayo_reftech
@jrmayo_reftech 2 месяца назад
Glad you enjoy it!
@Reefertech
@Reefertech 4 месяца назад
I’ve fought those EEV’s on the condensers/chillers shutting and causing high vessel pressures at a target. PID and TR was out of wack, causing daily discharge trips. Good times.
@Alex.The.Lionnnnn
@Alex.The.Lionnnnn 4 месяца назад
No idea how I found your video, but now that I'm here I have a question. I'm 42, and ever since I learnt about adiabatic expansion at university about 20 years ago, I've wondered why fridges, freezers, AC etc uses so many different gasses to produce the same result. So in my head all I can come up with is the stability of the compound used. If it degrades over time and creates a residue then that's obviously a no go. Then I figure the temperature differential between compressed and expanded ought to be more or less the same between the various refrigerants . Unless domestic refrigeration compressors actually take them to the liquid state, then the enthalpy of the phase change will also contribute, but are domestic compressors really that hardcore? Very long winded, ranting way of trying to say it. If you can be bothered answering, then thanks! I tried googling but my god was there a lot of bullshit! 😂
@jrmayo_reftech
@jrmayo_reftech 4 месяца назад
Glad you found this. There is a lot that needs to be explained and can be very long but basically it’s about capacity and what the customer or engineer of equipment prefers. CFC and HCFC (like R12 and R22) are phased out because they had an ozone depletion potential so manufacturers started developing HFC but they have a high Global Warming Potential so they are being phased out. Different manufacturers developed different refrigerants and advertised to use them because they are better than the competition. Other refrigerants have a high compression ratio so basically depending on your design and capacity dictated which refrigerants worked best for that equipment. Hope this helps.
@Alex.The.Lionnnnn
@Alex.The.Lionnnnn 4 месяца назад
@@jrmayo_reftech Well it's just that a few years ago I bought a cheap bar fridge that was using cyclopentane. It's almost completely innocuous compared to CFCs, abundant and bloody cheap. So why the f*** haven't we been using it all along? Then during covid I picked up some work driving a truck, delivering Scope, Williams and a few other brands of commercial fridges/freezers. I noticed that even a good number of those were running on cyclopentane. That's why I've been left confused about it. For reference, I studied science at uni, majored in chemistry and pharmacology, and I'm still that little kid that says "but WHYYYYYY?!?" hahahaha. Hence why I'm here saying, "mr, but whyyyy??" lol
@R290s_biggest_fan
@R290s_biggest_fan 4 месяца назад
​@@Alex.The.Lionnnnn Because its flamable there are total charge limits. Propane i think is one of the best refrigerants.
@Alex.The.Lionnnnn
@Alex.The.Lionnnnn 4 месяца назад
@R290s_biggest_fan lol I know all bout charge limits. Back when I was at uni and was a typical poor student I did all of the work on my piece of shit car. AC compressor was fucked so I threw a cheap second hand one in. There was a guy around the corner from where I lived that did regassing for $50 ($60 with the dye). The problem was that he applied the very Aussie attitude of "ahh she'll be right" to adding the refrigerant. He'd open valve on the cylinder with no regulator for a couple of seconds and say "yep, that should it". For a while I had AC in my car that was like a blizzard in Antarctica, but then one of the lines just gave up a exploded with eough force to rip my bonnet open. 😂 Went to someone else to get the refrigerant refiled. 😂
@Go2.R3F
@Go2.R3F 4 месяца назад
CO2 IS LIFE......♻️
@Nth_Room
@Nth_Room 4 месяца назад
Add more videos
@m809krazee
@m809krazee 4 месяца назад
Awesome video, thank you for sharing and cheers! I used to work with Excell Refrigeration in SoFlo along John D, Dave M., Pete H. He used to be our Service Manager. Good days! Thanks again
@neelkamalmohapatra
@neelkamalmohapatra 4 месяца назад
what is happening here?
@rjdipcord1271
@rjdipcord1271 4 месяца назад
Extremely high volume refrigeration. I think this is for a Publix grocery store or distribution warehouse.
@m809krazee
@m809krazee 4 месяца назад
It’s a refrigeration C02 (carbon dioxide gas) rack system, instead of using typical refrigerant gases that include fluorocarbons, which are chemical compounds of carbon and fluorine. That ultimately per EPA can be harmful to the environment, . More than likely the application we see here is for a supermarket.
@hw9219
@hw9219 4 месяца назад
Very cool video!
@MKMMECHANICAL
@MKMMECHANICAL 4 месяца назад
Keep Crushing It With The Videos!
@Reefertech
@Reefertech 8 месяцев назад
Good find
@sampushin6958
@sampushin6958 Год назад
Y’all don’t miss a thing 😏🤌🏽
@xscorpx
@xscorpx Год назад
I used to build/weld those machine houses 20 years ago in Conyers, GA.
@nojokeleftbehind910
@nojokeleftbehind910 Год назад
Sweet! Hvacrefertech sent me!
@jeremykeith7570
@jeremykeith7570 Год назад
Pretty sick. Let’s see more. Hvacrefertech says you got more gas in that tank 🫡
@stevec7607
@stevec7607 Год назад
Great Info
@clappedstoryalert
@clappedstoryalert Год назад
Keep up the good content. Hvaclife
@Nruvim31
@Nruvim31 Год назад
Keep up the good work 👍
@Nruvim31
@Nruvim31 Год назад
Got here from good old HVAC_REFER_TECH 👌
@danielchavez6647
@danielchavez6647 Год назад
@hvac_refer_tech 🙌🔥🙌🔥
@precisionllc1107
@precisionllc1107 Год назад
Keep posting great video! HVAC refer tech! Let's go!
@hw9219
@hw9219 Год назад
Would love to see more videos from you
@JulioGarcia-zf6sc
@JulioGarcia-zf6sc Год назад
Good to know ..
@excelluniversity569
@excelluniversity569 7 лет назад
great video