Dear professor tq very much. I am interested to write journal papers in this area. But, I don't have that much knowledge in hardware model. Plz , give the details to setup the hardware for simple system. Waiting for your response..Tq professor
Hello Professor Francisco, thank you for your videos. I have learned a lot from them and I appreciate your contribution to the study of power systems. I have a question. Is there an option in PowerFactory to obtain CCT in one run? I am currently using ETAP for getting CCTs and it takes me quite a bit of time because I have many scenarios. I have heard that PowerFactory can provide the value quickly without doing iterations manually. Is that true? Thanks.
Hello I want to make default acquitement automatic from SCADA because when I make an order close to the circuit breaker from SCADA it's couldn't execute it needs Acknowledgement default locally in front of the REF 630 relays If you have a solution I will be thankful Mr
Thanks for the wonderful videos I coming to you asking you for a solution My issue is when I have an any a detection fault on the REF 630 I can't lance any commands from the SCADA driving center except in an the case where an employee come into the substation and proceed to default acknowledgement In front of the relays REF 630 so in conclusion I want to tell you now in my relays there is a condition to make a maneuvre (close circuit breaker ) from the driving center the condition is acknowledgement default if you have a solution for this kind of issue I will be thankful for you to tell me
Muy buena explicación Dr. , aparece el siguiente mensaje: " Se ocultaron 63 videos no disponibles" , habría forma de que se habilite todos los videos porfavor. Gracias por el apoyo.
It's very very informative video. I want to learn more proficiently because i am working on Virtual power plants. Please I need your help. I will be very thankful to you.
Saludos estimado, se que es posible la conexion USB al CMC, pero no tengo tutorial de ello, ha contactado a los amigos de OMICRON? En que pais esta usted?
@@FranciscoGonzalezLongatt en colombia, la pc reconoce el cable, la licencia del equipo está instalada, pero cuando doy abrir alguna prueba dice no conectada
@@FranciscoGonzalezLongatt además le escribí al representante en colombia pero dice que ese modelo está descontinuado, que una posible solución es actualizar el firmware, pero no tiene el archivo
I know this is like 3 years old but do you have any notes, a video or a suggestion for documentation that covers the process of reaching the relay remotely over wan?
Muy buen video , por favor donde podria encontrar en venta en USA ( usado y certificado ) sobre este equipo CMC 256plus y CMC 356. Gracias de antemano por su ayuda
Dear professor Gonzalez, thank you very much for the informative class not only for students but also for professionals. Just one small feedback. It would be great if you add the link of related videos in the description of each video so it is easy to find them. I look for the part 2 of this video but unfortunately didn’t find it.
Profesor Francisco, realice en un sistema de prueba la implementación del sistema de control en frecuencia, y si responde a las curvas que usted menciona en la presentación, saludos desde Bolivia.
Felicitaciones!!! Que bien, si es algo sencillo, nuevamente felictaciones y cordiales saludos desde el UK. Pregunta, para que esta haciendo eso? FGL. PD: Se puede suscribir :-)
@@FranciscoGonzalezLongatt -comentar que en Bolivia está ingresando generación con base en las energías renovables (Fotovoltaico y Eólico), se pretende alcanzar cerca del 35% de la demanda de Bolivia. En la Universidad Mayor de San Andrés estamos en temas de tesis acerca del análisis de estabilidad de frecuencia por el ingreso de este tipo de generación, saludos cordiales desde Bolivia