hello sir i have a question you make 5 as the different to turn off the output but when the water level goes higher then 255 the output didnt turned off even when it reached 300
Hi there, Each device has a MAC address. you can use MAC address to make connection with PLC and define its IP address. After that you can connect via the IP address.💚💚
Hi there, when I click on Filling or Discharging buttons on the HMI screen, PLC sends number 27648 to related analog output. When I release them, PLC sends 0 to the related analog output. The logic which turns off valves inside the Manual function is not displayed during the video. Instead of that, you can see the logic that turns off the discharging valve inside the Auto Function. Note that, the Manual logic of the discharging valve is the same as its Auto logic.
Thanks for sharing useful information.I need advise related to 1756 ENBT Ethernet card communication. Usually We communicate with Allen Bradley PLC and(RS logix 5000,RS links ) via Control net module.We use also ethernet module for remote monitoring. "Network" light of Ethernet module is flashing green instead of steady. IP address is Ok and RS links see Ethernet module on rack.But when we check Module Properties from RS Logix 5000 it showed "Internal state : unconnected." I checked this module in other PLC rack and worked fine.But in own rack is not working I check new Ethernet module in the same slot but the same problem.Even i put to other slot no any good result.Could you please give me advise
Hay alguna manera de poder conectar el HMI real al PLCSIM o simular la CPU y que sirva para conectarse al HMI real. Intento hacerlo, pero al simular la CPU me sale un dialogo mencionando que al simular se desactivan el resto de conexiones, incluidas la de ethernet y por tanto no puedo conectarme al HMI real.
I have not connected a real HMI to PLCSim. I think it is not possible to make a direct connection. Maybe an intermediate app like an OPC server can help you to create this connection. However, KepserverEx is software that can create an OPC server.
Thank you so much Sir. great work. I saw you have a training online on website udemy. Sure I will buy your training. If you do another training I will buy it and doing ads for you.