This channel is all about lighting design. Mosty, tutorials about lighting design using different software like Dialux Evo, Dialux, Relux, AGI32, Photoshop, Sketchup and AutoCAD. For more info, visit www.nrocolightingdesign.com
It is more accurate to say we can pan using the "middle button" rather than the scroll button, because my scroll button and middle button are different ones and I was able to Pan only using the middle button. Another option is to press P (hold), and left mouse button. Thanks for the video though, you may be the only person who wrote about the answer on the whole internet!
I stil not get why there is only a lower limit luminance for the road, but a lower and an upper limit for the sidewalk illuminance in the IEC 13201 standard? And rightly, for the sidewalk, Dialux interprets that requirement as not satisfied, reporting the red cross.
I believe your UGR value will be its highest at the location the maximum distance away from your luminaires, for example the point in the center of the 2x2 luminaire grid. This area is receiving brightness from four luminaires at a high beam angle. I noticed you selected a wide distribution for your lighting. Would your UGR drop if you used more luminaires (tightly spaced) with narrower beam angles?
Hello Respected Ma'am, I am working on a project at our hospital which includes shifting of pole solar lights to pole flood lights because of poor lighting and performance of these solar ligths. Ma'am, we have the boundary wall around the hospital buildings which lengths 531meter south wall, 440meter northside boudary wall and approximately 220 meter each each and west boudary walls. We have 62 poles already installed for solar lights what i am going to do is to replace solar lights with phillips 100w flood lights to improve serveillance and security of the hospital boundary wall and i do not have any site plans to import into dialux evo 12.1. Please suggest me for having proper working on this project at dialux.
Hello Respected Ma'am, I am working on a project at our hospital which includes shifting of pole solar lights to pole flood lights because of poor lighting and performance of these solar ligths. Ma'am, we have the boundary wall around the hospital buildings which lengths 531meter south wall, 440meter northside boudary wall and approximately 220 meter each each and west boudary walls. We have 62 poles already installed for solar lights what i am going to do is to replace solar lights with phillips 100w flood lights to improve serveillance and security of the hospital boundary wall and i do not have any site plans to import into dialux evo 12.1. Please suggest me for having proper working on this project at dialux. A bundle of thanks.
Hi nelca, when working on indoors, is the ground and 2nd Floor will be read in dialux evo as floor elements or a storey? Lets say i made a whole building with interiors on it on sketchup and apply lighting on dialux evo, is this possible? Ty in advance
Hello, I have a question. Can you change and increase the road length in Dialux in Street Lighting? I need to know the answer to this question because I can only modify the width and number of lanes
Hi Nelca, thanks for this video. I think your calculation point it's ok because it has 0,00 height parameter. I'm doing a similar office calculation, and I put the calculation point at 1,2mts and I surpassed the UGR limit. Please tell me what you think of this issue. Thanks in advance!
Hello dear Nilka Firstly, I would like to thank you for all your efforts, and I am a huge fan of yours Secondly, I have a question I am working on a project and needed a 3D model I tried to make it on programs such as AutoCAD Blender Free Auto But the Deluxe couldn't import it I do not have the ability to purchase SketchUp, Revit, or 3D Max Is there another way to do this? I hope you will answer me and accept all my regards 💜💜
Yes. It's possible. Just change the height. You can only do it once. Do not worry about the value if it returns to 0.3. The height has already changed in actuality
Muchas gracias. Este video me ha ayudado mucho. Yo tengo la version 12 y no me salia esta ventana previa al importar. Pero era porque yo estaba importando un archivo LTD y no un archivo IES. Cuando me he dado cuenta y he cambiado el nombre de la extensión del archivo ha funcionado a la primera.
Thank you so much. This video has helped me a lot. I have version 12 and this previous window did not appear when importing. But it was because I was importing a LTD file and not an IES file. When I realized it and changed the name of the file extension, it worked the first time.
Make sure ur calculation points are above the object. Also u need to select properly all the output data on the export properties. U need to Include the Calc points in the export. And don't forget to turn on the real-time values.
My website is www.nrocolightingdesigns.com. make sure you add "s" on the designs. My old website domain name has been bought by somebody else. U may also send me an email to nelca_roco@yahoo.com or nrocolighting@gmail.com
DEAR MASTER I HAVE ONE PROJECT IN PDMS & DUE TO GETTING 3DS FORMAT I HVAE FORCED TO CHANGE RVM FORMAT TO 3DS ...HERE IS THE PROBLEM THAT ALL PROJECT IS ONE OBJECT BUT I WANT SAPARATED ANY OF OBJECTS ... ONOTHER QUESTION IS THAT ..IF CLCULATE LIGHTING BY THIS CONTION ..IS THERE NO PRBLEM IN MY OUTPUT ??