Тёмный
Fridays With Brandon
Fridays With Brandon
Fridays With Brandon
Подписаться
Welcome to Fluke Fun! We explore all things Fluke, what’s NEW, how to use, unboxings, and answering questions you all have!

I know what I know because I work for and sell Fluke tools in the Cincinnati Market.
Fluke BT521 - Fluke Fridays - Episode 127
7:23
5 месяцев назад
1777 accessories - Fluke Fridays - Episode 125
5:01
6 месяцев назад
Viewer Pro tips - Fluke Fridays - Episode 124
4:38
6 месяцев назад
Fluke-365 - Fluke Fridays - Episode 118
3:10
9 месяцев назад
TV36 Walkthrough - Fluke Fridays - Episode 112
8:24
11 месяцев назад
Комментарии
@billwheeler1213
@billwheeler1213 3 дня назад
Perfect for my decision! 789 it is (not an elec-chicken, but a plant commissioning/troubleshooting tech) :)
@mrj5417
@mrj5417 5 дней назад
Those can be used to measure batteries , while UPS system is ONLINE/charging?
@fridayswithbrandon
@fridayswithbrandon 3 дня назад
@@mrj5417 yes unless you are doing a discharge test.
@mrj5417
@mrj5417 3 дня назад
@@fridayswithbrandon Thanks for the feedback ! Will check also your software video once I unpack the instrument. Some proper field measurement procedure from somebody on a live UPS would be informative. :D
@billusry8902
@billusry8902 6 дней назад
I am enjoying learning about your real estate investment journey.
@fridayswithbrandon
@fridayswithbrandon 3 дня назад
@@billusry8902 thanks for the feedback. I will make more videos I've just been very busy with our latest investment. I will get back to it when the kids are back in school.
@bissibi2027
@bissibi2027 10 дней назад
I need your help!!!!!!! need to buy a power analyzer: The power input to our traffic signal cabinets is 120/240 single-phase. We are interested in assessing AC power grid quality. The typical AC RMS current for a traffic signal cabinet ranges between 30 to 60 amps, we will need to leave the Monitoring unit inside the cabinet for a few days. It is essential to be able to email the recorded data to the electric Company, so having reliable and secure data is important. The cabinets are located on the street, and environmental factors such as humidity, as well as low and high temperatures, May affect the cabinets.
@fridayswithbrandon
@fridayswithbrandon 8 дней назад
I would recommend one of the following: Fluke-1736/EUS or Fluke-1746 (no screen but can handle harsher environments) Fluke-1736/EUS (do not get the "B", you wont get the accessories you need) - www.amazon.com/dp/B016DPDVI8?linkCode=ssc&tag=onamzbra04d98-20&creativeASIN=B016DPDVI8&asc_item-id=amzn1.ideas.2XZ847JBOA5EJ&ref_=aip_sf_list_spv_ons_mixed_d_asin Fluke-1746 - www.amazon.com/dp/B07DY3N3Q4?linkCode=ssc&tag=onamzbra04d98-20&creativeASIN=B07DY3N3Q4&asc_item-id=amzn1.ideas.2XZ847JBOA5EJ&ref_=aip_sf_list_spv_ons_mixed_d_asin
@eliasmylonas9530
@eliasmylonas9530 11 дней назад
Hello Brandon, very nice video presentation. Could you please let me know what is the model number of the adapter that you are using in your power outlet to connect your 1777 to power?
@fridayswithbrandon
@fridayswithbrandon 11 дней назад
@@eliasmylonas9530 are you talking about the blue jumper cables? Or the cord plugged into a outlet?
@mijboogie
@mijboogie 12 дней назад
T6 is to big. I regret buying it
@fridayswithbrandon
@fridayswithbrandon 11 дней назад
@@mijboogie sorry to hear that
@HuskyNoKokyuu
@HuskyNoKokyuu 16 дней назад
"Source is used if you don't have a power source, but if you don't have a power source then you would use simulate" Uhh, what?
@fridayswithbrandon
@fridayswithbrandon 11 дней назад
@@HuskyNoKokyuu if you do have an external power source outside of the meter then you would use simulate.
@jeremyvasquez9616
@jeremyvasquez9616 17 дней назад
I got you! thank you for the help
@gurumurthyarun
@gurumurthyarun 19 дней назад
Can you buy the alligator clip and install it on T6-1000 later..
@nikobobich9726
@nikobobich9726 22 дня назад
Greatest meter ever 87v
@billmuertos
@billmuertos 23 дня назад
Awesome vid thanks. I hadn't heard of it
@TheEspinoza-hf1xf
@TheEspinoza-hf1xf 27 дней назад
What happens if a 3ph compressor fails the insulation test???
@fridayswithbrandon
@fridayswithbrandon 26 дней назад
@@TheEspinoza-hf1xf it could indicate it will stop working very soon or it's already no longer able to run. As far as how to repair it would need to be replaced or sent to motor shop for re-winding.
@awebuser5914
@awebuser5914 Месяц назад
My 3000FC and Fluke Connect does not offer the little down-arrow in the app. to change the sampling log timing. Is this a limitation of the "free" version of the app? Also, have you done a show on the differences between the free and subscription "benefits" of the Fluke Connect app? The Fluke sales info in incredibly vague about what is offered with the free (no subscription) version and with paid subscription, I'd say to the point where a buyer might be discouraged since it _appears_ that you pretty much need a subscription, making it useless for amateur uses.
@epikx1934
@epikx1934 Месяц назад
How do you turn the beep back on?
@fridayswithbrandon
@fridayswithbrandon Месяц назад
@@epikx1934 I'm not sure off the top of my head. But I think if you cycle it off and back on it should reset itself.
@user-ey1wy1up6t
@user-ey1wy1up6t 25 дней назад
​@fridayswithbrandon that's what worked for me.
@k1_w3
@k1_w3 Месяц назад
Don’t forget to LIKE and SUBSCRIBE. 👍
@k1_w3
@k1_w3 Месяц назад
@FWB Thanks for making a video on the 302+. I was really curious about it because it was selling for so cheap on AMZ, so I was wondering if maybe they were Chinese knock-offs or something. I have a T6-1000 Pro, but I’m going to pick up a 302+ just to mess around with.
@herbfellows6435
@herbfellows6435 Месяц назад
Finally, someone who knows how to explain things. I'm not sure how much time and effort you put into what you were going to say, but it was fantastic! Clear and precise with no detritus, annoying music, or even worse, no speech at all. Well done.
@enriquealvarez2045
@enriquealvarez2045 Месяц назад
Thank you sir
@davidlindgren7605
@davidlindgren7605 Месяц назад
only problem with the video is my capacitor has 3 terminals, not 2, so I"m totaally confused!
@anotherbrickonthewall
@anotherbrickonthewall Месяц назад
If it for AC, you should have a C terminal, Herm, & Fan. Your capacitor will have a number like 45/5uf. Check between C & Herm will be the higher number (45) and between C & Fan will be the lower number (5).
@fridayswithbrandon
@fridayswithbrandon Месяц назад
@@davidlindgren7605 I believe that kind of capacitor has 2 capacitors in one. Like a starting capacitor with one microfarad setting for starting the motor and a second for running the motor. The ratings should be on the side of the housing.
@davidlindgren7605
@davidlindgren7605 Месяц назад
@@fridayswithbrandon I think you're right. My capacitor is fine. Turns out the problem was a simple 3 amp fuse on the circuit board that had blown. My advice to others is always check the "stupid stuff" first, like fuses, circuit breakers, etc, before panicking and assuming the world has ended with a blown capacitor or motor failure.
@k1_w3
@k1_w3 Месяц назад
Have you done a review of the Fluke 302+? I’m curious why there aren’t really any reviews on RU-vid.
@fridayswithbrandon
@fridayswithbrandon Месяц назад
I don't. But if I can get Fluke to send me one I will make one. Or I could do a video I talk about it but I just wouldn't have it in my hand. Let me know if you see value in my making a video I talk about the good and bad of the tool.
@k1_w3
@k1_w3 Месяц назад
@@fridayswithbrandon I would be curious to see a review of it, whether or not you have one in your possession. It has a lot of sales on AMZN, but I can't seem to find anything except a few short reviews in foreign languages on RU-vid.
@EonTide1111
@EonTide1111 Месяц назад
Do you need a subscription to use it ? Or is that just to use remote monitoring . Does it have usb to transfer data to a laptop ? Also does it have blue tooth fc capabilities ?
@fridayswithbrandon
@fridayswithbrandon Месяц назад
No subscription. But with remote monitoring you have a few options. Best would be to buy the cell phone modem adaptor and get a Sim card. Then you can download the data remotely. If you want a streaming service I don't think that is available. If they do make it available someday that will be a subscription. I have a video on how to transfer data. But yes you can transfer Data to laptop via USB cable, USB flash drive, or wifi direct connection. Yes some Bluetooth FC capabilities.
@fridayswithbrandon
@fridayswithbrandon Месяц назад
Also, call 800-44-FLUKE for any specific questions
@EonTide1111
@EonTide1111 Месяц назад
That power analyzer is incredible
@stevethetoolman2435
@stevethetoolman2435 Месяц назад
Very informative. Ty
@sagarrp22
@sagarrp22 Месяц назад
thank you for your video. keep it up.
@stinkycheese804
@stinkycheese804 2 месяца назад
I can't believe that you felt this was necessary to mention. Someone who can't read that when it's right there on the tool, is probably too dumb to not point the laser in their eye anyway, so shouldn't even be allowed to have access to one. Better to mention who really needs the $160 Fluke and who would be an idiot to pay that much for it when the generics are under $10 and up. Yes I'm aware it has two dots. Woohoo. For that price I'd expect a laser circle even if it took a half dozen laser heads and optics to get there, and for it to include a miniature gnome in the box to use it for me, lol. Hint to people that don't understand: The Fluke is not a high precision, lab grade instrument so it is madness to pay that much for it. Get the real deal or don't, but don't overpay for the name. Besides, it's a crappy design. Printed on, rubber silicone button markings wear off. You should never accept that on any but the cheapest of equipment. I wouldn't be surprised if Fluke will sell you a new button membrane, for more than the whole tool is worth.
@emilmckellar4932
@emilmckellar4932 2 месяца назад
You realy have no idea what this is and how valuable it is to electricians almost everywhere? Why review what you know nothing about?
@emilmckellar4932
@emilmckellar4932 2 месяца назад
Electrician in South Africa here, Every chance I make, new socket install or move a light anything, I must compile a COC, Certificate of Compliance for the full home. If the owner has one I can add an amendment to it. Same as EU. If owner sells his home, and coc is older than 2 years he must get a new one. So not just inspector but every sparky MUST, have installation tester. Prove you did your work right and installation comply to building and Electrical regulation
@Lisa-bi9nu
@Lisa-bi9nu 2 месяца назад
Can you please explain how the "Local Logging" option works?
@fridayswithbrandon
@fridayswithbrandon 2 месяца назад
I would call 800-44-FLUKE and have them walk you through how it can be done. That is if it can be done
@Adil-zx9sz
@Adil-zx9sz 2 месяца назад
Can this power quality analyzer measure up to 11kV medium voltage? Will PTs (Potential Transformers) be required for this?
@fridayswithbrandon
@fridayswithbrandon 2 месяца назад
You would need PTs. It has a voltage ratio you can enter. But the meter itself should never be exposed to more than 1000 V. With PTs and the voltage ratio the meter will display a higher voltage. Example if you had a transformer that was 100 to 1 ratio the meter would read 110 volts from PT but would display on the screen 11,000 Volts. Again - NEVER CONNECT METER TO MORE THAN 1000V
@abubakaralagab3188
@abubakaralagab3188 2 месяца назад
That is very interesting Thankfully
@raulsilva6697
@raulsilva6697 2 месяца назад
I love that it has all in one . I'm tempted to get this for my hvac bag
@fridayswithbrandon
@fridayswithbrandon 2 месяца назад
If you do and you don't have a local distributor your already working with. Use the Amazon link below
@alexkelker
@alexkelker 2 месяца назад
Great video!!
@Interestinglybored209
@Interestinglybored209 2 месяца назад
Thank the Lord for you
@Interestinglybored209
@Interestinglybored209 2 месяца назад
Thank you Brandon, I’m excited to watch!
@reddee2750
@reddee2750 2 месяца назад
709h is it posible change of range?
@fridayswithbrandon
@fridayswithbrandon 2 месяца назад
Not sure what you mean by change of range
@reddee2750
@reddee2750 2 месяца назад
@@fridayswithbrandon i mean input range, eg : 0 - 10 bar change to 0-8 bar transmitter use HART, is it possible ?
@fridayswithbrandon
@fridayswithbrandon 2 месяца назад
@@reddee2750 yes you should be able to change the transmitters parameters using the 709H or 710
@johnlucier8572
@johnlucier8572 2 месяца назад
You better look at the specs on amprobe not close to fluke. Safety fine, but for ac dc ohms and everything else forget it not close to fluke.
@fridayswithbrandon
@fridayswithbrandon 2 месяца назад
Agreed. But what I'm talking about here, is if you choose not to buy Fluke because of price. The competition to Amprobe at the Amprobe pricing is not as safe as Amprobe because Fluke owns Amprobe and has the ability to test for safety in house.
@johnlucier8572
@johnlucier8572 2 месяца назад
By the way fluke and amprobe are the same co panty with another meter under a co panty who holds them under their licenses...
@johnlucier8572
@johnlucier8572 2 месяца назад
The accuracy is not there on the amprobe. They have nice meters but nothing beats a fluke period
@TheMartinez20m
@TheMartinez20m 2 месяца назад
Did you try to use feature save to shared folder through wifi connection? I've tried with no success
@fridayswithbrandon
@fridayswithbrandon 2 месяца назад
I don't think I did. You should call tech support they will try with you or let you know it won't work. 800-44-FLUKE
@HiFiInsider
@HiFiInsider 2 месяца назад
Fluke said my vintage Fluke 10 should use TL75. Would the TL175 work on my meter?
@fridayswithbrandon
@fridayswithbrandon 2 месяца назад
Yes if the TL75 will work the TL175 will work as well. See my Amazon link below if you plan to buy from Amazon
@fridayswithbrandon
@fridayswithbrandon 2 месяца назад
amzn.to/3PJ9Yp4
@Interestinglybored209
@Interestinglybored209 3 месяца назад
I love the real estate talk, thank you Brandon!
@rw5694
@rw5694 3 месяца назад
Nice tracer, i have the ideal 61-957 tracer also a good tracer. Ive tried klien ET450 i found its comparable to the ideal tracer for much less cost price. Effectiveness of these tracers is largely related to user on how to use them properly.
@tylerlawrence4885
@tylerlawrence4885 3 месяца назад
I Found your channel because I have an appreciation for Fluke meters and own a bunch of them. I grew up going to church, I have a few rental properties. I am trying to decide right now what to do with my electrical contracting business. I guess I just want to say I appreciate what you are doing and I am grateful that I found your channel!
@fridayswithbrandon
@fridayswithbrandon 3 месяца назад
This is my all time favorite comment I've ever received! Thank you
@benedictomnubi5934
@benedictomnubi5934 3 месяца назад
From Dar es Salaam Tanzania, thank you for the explanation, we have the analyzer on our office, and I have to attend the customers. Through this video I'm building a confidence of interpreting the measured results.
@victorm.4167
@victorm.4167 3 месяца назад
I paid 1000$ for mine and the $50 new Klein is easier,faster and cheaper. As for tracking wires and opens after a few hours when I couldn’t find the open myself I did narrow it down to a hallway ceiling and the customer said he would fix it him self. So it’s a last resort thing but I did have luck with the same type the Ideal one . I have this one also for. $1000 had one go bad, returned it , it’s great dog and pony show at best. Expect to spend 2-4+ hours fkn with this sensitivity problem and narrow down the issues. I diagnose problems residential every day and I may use this once in five years because I can find the problem faster with my traditional troubleshooting methods. So if you got 1k to throw it will find your circuit breaker for sure but it’s a lot of bull shit running ext cords and finding grounds that’s not connected to your short or open,and the sesativity button is a fkn absolute joy to fk with. It’s not worth the 1k people like the $300 Klein and the $50 newer Klein for finding cb the easiest
@michealfam6203
@michealfam6203 3 месяца назад
How to calibrate ohm with 2 probes touch on?
@fridayswithbrandon
@fridayswithbrandon 3 месяца назад
Do you mean like zero out the probe resistance?
@Die-Spezialisten
@Die-Spezialisten 3 месяца назад
The 87-5 max / 28-2 has a lower diode test voltage than the 87-5. I like the Flukes also because of the diode test, because you dan test LEDs. I often do it at work when testing new PCBs. I donßt like to focus my view on the inside of the LED, so i put my Fluke 2 testpins. It works woth the 82ii/87vmax, but not so good as with the 87v. I think that is because the 85v uses a 9V battery and the others three or four 1,5V AA. I recommend lithium batteries for this kind of devices. I got the 82-v EX for a good price. Once i wanted to use it again, it didn´t turn on. I thought low battery. The batteries were leaked out and damaged the plastic and the contacts on the PCB. Never again! This was a very expensive thing to get a new one for a good price. The old one works again at a colleagues home workshop, but no more "ex", because he has fixed it with a lot of work and cleaning material!
@alexkelker
@alexkelker 3 месяца назад
Great video! Lots of good information here!
@LigmaRecaps
@LigmaRecaps 3 месяца назад
Are you looking for a video editor, thumbnail designer?
@fridayswithbrandon
@fridayswithbrandon 3 месяца назад
Maybe what would that look like?
@LigmaRecaps
@LigmaRecaps 3 месяца назад
@@fridayswithbrandon Anything you want. And if you don't really know what you're looking for, I'm going to search through your best performing competitors and I'm going to replicate their styles.
@fridayswithbrandon
@fridayswithbrandon 3 месяца назад
@@LigmaRecaps what would it cost?
@LigmaRecaps
@LigmaRecaps 3 месяца назад
@@fridayswithbrandon For the thumbnail, it's $5 and for video editing, it's $3 per edited minute.