🙏नमस्कार..मेरे प्यारे भाई,बहेनो आप सभी को इस चॅनेल पर एअर कंडिशनिंग और रेफ्रिजरेशन और इलेक्ट्रिकल फिल्ड से जुडी हर प्रकार की आवश्यक जानकारी मिलेगी. कोर्स सिखने के हेतू इस नंबर पर अवश्य फोन करे. 8446955859
Hai sir one dought sir pls tell me sir Samsung 190 ltr single door fridge capilary 0.031", 9 feet, filter, evaparetor, Condensor, Compressor R134a oli 210ml, R134a 10 psi charge . Totally change but filter(drayer) over heat what sir problem Lg 42 compressor use running amps 5-7 Slove filter heat
Thanks for this video. I am trying to fix Amazon Basic double-door fridge. R600a After gas charge and running for 12 hrs. Freezer temp is -20 'c Outside temp is 34 'c Compressor top is hot. Half of Condensor on side of fridge is hot. Rest is warm. -6 psi running pressure showing. standing pressure keeps increasing as the fridge gets warmer. 25 then 40psi There is ice on the suction line. How to get the correct gas pressure?
Free fire mein solvent dal dijiye jiska sada bhasha mein white petrol kahate Hain o flashing ke liye sabse bada chemical hai Nagar flashing ke liye nitrogen chahie chahie chahie chahie chahie chahie chahie chahie chahie
Thank you for this vid. 1. If compressor and condensor feel very hot 🔥. What cud b wrong? 2. The condensor is hidden inside the body. Then how to check it?
I have Amazon Inverter and Whirlpool inverter intellisense 2-door fridges. Both have Freezer temp -15.6 deg c. are these Fridges cooler than What you are showing? asking bcoz I have Old Model non-inverter LG 2-door fridge Also. It takes 5 units (KWhrs) in 24 hours. not sure if I get it repaired. Freezer temp was -5 deg c Thanks