Тёмный
RLC Electricals
RLC Electricals
RLC Electricals
Подписаться
Комментарии
@SubratkumarJena.
@SubratkumarJena. 3 дня назад
Yahi baat Maine kitna samjhaya jo stabilizer kartehain ki window area aur cross sectional area transformer ki power rating aur minimum input voltage se related hain. Lekin unhone kuchh bhi calculation na karke dekh kar 5/10/15/20 kva ki automatic stabilizer bhi banate hain fir 90v minimum input voltage me. Aur unka wohi 5 kva ka stabilizer jiska output power 3.2 kw hota hai ek 746watt motor ko nehin chala pati hai. Aur puchh ne se bolte hain ki wo surf 10A ki input current hi le payega. To unka stabilizer sirf(90×10×0.8) =720 watt input power lega aur (720×0.8) =576 watt hi deliver karega to wo log kaise utna jhut bolte hain aur ye log bhi kabhi bhi iske bare me kuchh bhi complain nehin kiya aai tak. Me bhi bolta tha ki Meta ai app se puchho. Lekin aap ne jo bhi kaha 100% sahi hai. Pehle calculation baad me core selection aur bobbin aur swg wire selection.
@GautamKumar-su3bp
@GautamKumar-su3bp 4 месяца назад
🤣🤣🤣🤣, ओर पावर कलकुलेसन कैसे होगा। बिना पावर का वायर का साइज कैसे सलेक्ट करेंगे।
@maths10class7
@maths10class7 4 месяца назад
ग्रेट जॉब सर
@maths10class7
@maths10class7 4 месяца назад
सर जो फेमस चैनल है वो सब इतना डिटेल से नही समझाते हैं न ही इतना अच्छे से समझ में आता है में तो सर आपका फैन हो गया हु
@GautamKumar-su3bp
@GautamKumar-su3bp 4 месяца назад
सर भी डिटेल नही बताये हैं 🤣
@mirali7230
@mirali7230 8 месяцев назад
Sir buck boost transform winding calculatio
@mirali7230
@mirali7230 8 месяцев назад
Sir very good
@Electronics_knowledge
@Electronics_knowledge 10 месяцев назад
Sir, agar mujhe 210-470V Input Range and 240V output ka transformer design karna ho to kese hoga.
@surinderjat1969
@surinderjat1969 Год назад
Brother, 300 volt out put or .80 amp ke leye kon si wire use kare ,agar input 220 volt ho or wire ka size bhi batna dono ka
@abhishek.pateljii6264
@abhishek.pateljii6264 Год назад
Step up transformer me bhaiya primery coil aur secondary coil एक दूसरे से जुड़े hote hai ya step down transformer k tarah seprate hote h
@adeshkumarjha4891
@adeshkumarjha4891 10 месяцев назад
Seperate hote hai.
@arohisingh5945
@arohisingh5945 Год назад
Step down transfarmer nm of turn kaise nikalte hai
@techhindipro9127
@techhindipro9127 Год назад
Wire ka gage kaise nikal na he
@vijaysharma-ww3ij
@vijaysharma-ww3ij 2 года назад
योग्यता आवश्यक सामर्थ आता नहि नकल कर सकता वह तक पैठ भरा है
@vijaysharma-ww3ij
@vijaysharma-ww3ij 2 года назад
Thanks sir ji
@maphistoplayz2351
@maphistoplayz2351 2 года назад
The same works for ac and dc current both?
@rlcelectricals7437
@rlcelectricals7437 2 года назад
Buddy transformer only work in ac not dc
@maphistoplayz2351
@maphistoplayz2351 2 года назад
@@rlcelectricals7437 😅😅
@wistoncoin
@wistoncoin 2 года назад
Bhai mujhe 6 v se 230 volt banana hai ban jayega kya step up .
@maphistoplayz2351
@maphistoplayz2351 2 года назад
Hard but possible
@maphistoplayz2351
@maphistoplayz2351 2 года назад
But try to get more volt on primary
@jaanzahidbrothers9766
@jaanzahidbrothers9766 2 года назад
Good
@SonuJngr
@SonuJngr 2 года назад
भाई एक सलूशन को आप यूज करके बताओ इसका जो कैलकुलेशन फार्मूला है प्लीज इसको पर एक वीडियो बना
@raspalluhar2120
@raspalluhar2120 2 года назад
Sir हमें 70 volt mein output में turn ka calculate करने में समझ में नहीं आ रहा है
@abedashaikh6130
@abedashaikh6130 2 года назад
Kunsa wire ka number lagega
@damodarkoirala6131
@damodarkoirala6131 2 года назад
What specifications should I need to make a step-down transformer 230v ac to 130v ac of 1.5 kw/ampere? e.g. * core and bobbin size, * wire gauge and turns for both primary and secondary windings. * Any others things which I forgot to mention here.
@Hollywoodstar-o6n
@Hollywoodstar-o6n 2 года назад
Mujhe wire no clear nai hua plz tell me
@alicoolpoint153
@alicoolpoint153 2 года назад
Shandaar Bro...♡❤♡ Good Job 👍
@viswanathancr2801
@viswanathancr2801 2 года назад
good video
@lastminutes703
@lastminutes703 3 года назад
7no or 8 no cor ke lia 50 vote input 230 vote output 3 kva. transformar ki deta battya please.
@SubratkumarJena.
@SubratkumarJena. 6 дней назад
Yahan 50 v input aur 3 kva output ke liye aap ko (3000/0.8)=3750-va Ka input dena Hoga kyunki achhe quality ka transformer Ka efficiency 80% hi hai. To input current (3750/50)={375/5)=75A hi hoga . Aur (W×A)=3.75×18=68 - sq sq inch hi hai ,jiske liye koi bhi E,I core suitable nehin hai ye 7/8 no kaise soche Hain aap ne?
@lilitelaring357
@lilitelaring357 3 года назад
How to 35v -280v step up winding data
@chandreshtiwari6395
@chandreshtiwari6395 3 года назад
3 रूम और 1 किचन, गैलरी और डाइनिंग हॉल ,बाथरूम और लैट्रिन में छत की वायरिंग का कितना खर्च आएगा
@jaanzahidbrothers9766
@jaanzahidbrothers9766 3 года назад
Very good sir good video.
@mayurvn6848
@mayurvn6848 3 года назад
Thank you Very Much 🤩🤟
@AliHassan-gx9wz
@AliHassan-gx9wz 3 года назад
wire ka diammeter kasa nikala gy bro humainpata kasa chla ga ky hum ko itna diammter wire chaiya tu transformer work kara ga
@SubratkumarJena.
@SubratkumarJena. 3 дня назад
Power rating aur minimum input voltage se aur wo terminal me kitna minimum input voltage diya jayega ya output liya jayega. Kyunki ac me input Power in watts= Vmin×Imax×o.8 hi hota hai. Aur output power in watts=0.8×power input ineatts hi hota hai. = output minimum voltage× output current ×0.8 hi hai.
@sagarelectricals4283
@sagarelectricals4283 3 года назад
Dear sir, 90v to 440v automatic stabilizer transformer 5 loops ki tapping kitane kitane volts ka nikalte hain.
@dharmveershakya189
@dharmveershakya189 3 года назад
Nics
@nejibhamouda6022
@nejibhamouda6022 4 года назад
I would ask if you have an idea I bought last week a dead old brass doorbell on which is indacated 12 ac volts. The electricen said that the solenoid has a cooper wire of 0.5 mm and about 880 turns. But when i applied 12 ac volts the bell hardly vibrate and didn't make sound. I graduly increased the ac voltage until 30 ac volts where the bell function well. My questions are : 1/ Can I decrease the number of turns to let the bell function under 12 ac volts and how many turns. 2/ Can I function the bell under 220 ac volts and how to calculate the thickness of the cooper wire and the number of turns. Best regards.
@kolarkaraudioresearch
@kolarkaraudioresearch 2 года назад
Size of the core?
@manoharsinghmankoo9968
@manoharsinghmankoo9968 4 года назад
Ur letters and drawings in note book not visible. Pl on blackboard par explain karey
@rlcelectricals7437
@rlcelectricals7437 4 года назад
Ok i keep it in mind.if u want the PDF of this notes,then share me yours mail id
@koustavpati3549
@koustavpati3549 4 года назад
Good. Very good bro🌸🌸
@sagarjitadhikari5858
@sagarjitadhikari5858 4 года назад
Wah
@AnuragKumar-pq9vq
@AnuragKumar-pq9vq 4 года назад
bohot sandar...
@jitendrakharra2255
@jitendrakharra2255 4 года назад
Very nice information.. Ek cheese puchni thi...Apparent power ke according transformer core and bobbin size kaise calculate karte hai. Jaise 5KVA ke transformer ke liye core size or bobbin size Kya Hogi..
@safikhan6626
@safikhan6626 4 года назад
I have same question if you get it kindly reply
@enjoyboxayodhya7765
@enjoyboxayodhya7765 4 года назад
Good job keep it up 👍👍👌👌
@enjoyboxayodhya7765
@enjoyboxayodhya7765 4 года назад
👌👌👌
@abhisheksngh734
@abhisheksngh734 4 года назад
Bahut sahi bhai....Keep Going and Keep Growing
@pinkupal7039
@pinkupal7039 4 года назад
Love u sir
@samrendrasingh8949
@samrendrasingh8949 4 года назад
Good bhai
@Stories_with_PK
@Stories_with_PK 4 года назад
Nice
@rlcelectricals7437
@rlcelectricals7437 4 года назад
Thanks pallu
@ujjwalpanda79
@ujjwalpanda79 4 года назад
Round wala transformer ka formula yehi hai kya??
@rlcelectricals7437
@rlcelectricals7437 4 года назад
Hmm
@ujjwalpanda79
@ujjwalpanda79 4 года назад
Nice video bro..
@sagarjitadhikari5858
@sagarjitadhikari5858 4 года назад
Awesome
@rumaroy8998
@rumaroy8998 4 года назад
Nice👌👌
@chaitalinanda3541
@chaitalinanda3541 4 года назад
Very Good
@koustavpati3549
@koustavpati3549 4 года назад
Very good. Keep it up. Best wishes for you.
@mainakmazumdar6716
@mainakmazumdar6716 4 года назад
Very Knowledgeable!!