IGS Electronics is all about giving back to community what we have learned and are learning in industrial electronics and automation industry. From basic wiring of socket to full blown electrical panel, we will do it all. Our aim is to reach out to young and old upcoming engineers that are looking to learn with us, better there skill or simply learn something new.So if you are interested and want to join us on this canal, please subscribe and our promise to you, we will not disappoint.
Hi, do you know if it is possible to make a similar system with SICK UM18 serie? I don't understand if this is a distance sensor or a distance switch (only the detection of a threshold).
Hi, I upgraded the firmware version but I can't going to online. But I select the older version that time I can go to Online, there's any solution?.. Thanks
Very hard to follow your dialect/accent, but I'm sure you'd say I sound like a redneck 😂✌️. Wish you had a short video on just modifying parameter values
Hello How are you? I am Fahim and I want to help you I have a device plc cpu 1214c that has been programmed and a protection key has been placed and I cannot open the program and I want to delete the program from the device. What are the steps to delete the program from the device? Thank you for your cooperation
Well and thanks again..,but I've a question please! what can i do if my TECO e310 vfd is showing LU on digital screen and REV signal on remote controller pad??
Sir i have A740 vfd Mitsubishi. My set button not working so I can't change any parameters. So i connect my vfd with FR confuigurator and changed in 79 parmeter set 2 . Now my vfd running in ext mode with external potentiometer. But when power goes off my vfd automatically gone in NET mode whether 79 parameter 02 is present
Hello mate, i have a g110 ain but it doesn't allow me to access to the 700s parameters, even tho ive tried the number 1, 2 and 3 level of access (the 300). Is it possoble that this VDF in particular cant be turn on via terminals?
What is the parameters if I want to increase the speed while the motor is running. Now, I cant increase the speed P1082 because the motor is running. I need to stop the motor to change the P1082.
What is the parameters if I want to increase the speed while the motor is running. Now, I cant increase the speed P1082 because the motor is running. I need to stop the motor to change the P1082.
This is a massive help. Donyou have contact detail. I have a job up and coming that involves 8 pt100 thermocouples which I need to transmit the temps over a network to a scada system to control cooling fans. Want a job ?
Hi, I bought siemens logo from ebay and it is used. There is an existing program on it. Is there a posible to remove or factory reset the logo.thankyou😊
Hello, your videos are very good, I have a problem with that same variator. It does not turn me off through the selector and the other one is that with the potentiometer it does not remain at 00, it remains at 0.1 and the motor remains in slow rotation, what parameters will I use for this problem? I appreciate your help. ..Thank you
Hello, great videos. There is something I need to know; how to configure the direction of rotation. I read the settings in the manual and did what it said, but it still didn't work. Could you explain to me how and what parameters I should change, please?
Hi , I would like to find out on the pid temp block , when I restart the plc(cpu) the heat output goes to 100 percent , after a minute it comes back to 0 , how can I stop this with out switching the block off