Service Call..Breaker keeps tripping...
25:11
2 года назад
How to Flip a HotTub...
45:54
3 года назад
Комментарии
@alexsambolin6801
@alexsambolin6801 День назад
I live in Puerto Rico and I can't find one person who repairs yacuzzis. Can you walk me thru a diagnosis so I can do it myself? You can charge me for it. Thank you
@TheFiftyQuid
@TheFiftyQuid 5 дней назад
How do you fix a rotomold hot tub with a leak?
@spaman5440
@spaman5440 4 дня назад
Depends on were the leak is But for the most part I find and fix all leaks the same way...In your case I would need more details as to what is going on with your hot tub. Thanks for Watching & SUBSCRIBING
@scottweakley6570
@scottweakley6570 7 дней назад
Great video my breaker was tripping disconnected heater all good removed heater and found a large spring about the size of a hot dog and a plastic mushroom shaped part wedged against the element what could that be left side of heater I was trying to send a picture not sure how thank you for your help
@richfrench288
@richfrench288 8 дней назад
My breaker is still tripping with all these disconnected
@AnaMartinezT600
@AnaMartinezT600 11 дней назад
Very good info,I have an old hot tub,got it for free,but firs time I turn on it pull water trough the holes ,all good,but then I start touching small valve that is located on top I think is manifold open and close valve,and it stop throwing water ,and put on screen. Water in water heater got to hot 😢
@JodiLinnertz
@JodiLinnertz 12 дней назад
Are you experienced with inflatable spa jet systems?
@spaman5440
@spaman5440 12 дней назад
Over the last 10 year Ive play with several of them...call me at the shop and I will try to help You ..Thanks for Watching & SUBSCRIBING
@JodiLinnertz
@JodiLinnertz 6 дней назад
Phone #?
@ivorymason922
@ivorymason922 12 дней назад
Dude!!!!! The plunger worked!!!!!!! Thanks Man!!!!
@morsechode45
@morsechode45 12 дней назад
@spaman I have a hot tub that powers on, cycle through start up, ec mode, then starts flowing out jets. Blows for about 10 minutes never gets hot then pops the breaker. What are your thoughts?
@jeremykunzman1709
@jeremykunzman1709 13 дней назад
Question, I’ve got 6 gauge wire but instead of white, I’ve got a yellow. Am I still able to use it to connect the hot tub to the sub panel?
@desisat1
@desisat1 14 дней назад
Hey, B 570 - Pump 2 starts - the diverter valve fly away water pump up crazily. I would I like to know how to fix the loose threat diverter valve in Dynasty Spa B 570 model. Please help
@spaman5440
@spaman5440 13 дней назад
Replace it with a new valve...once the thread are not holding the only fix is to replace the whole assembly with a new one. Ive done several video on how to do this.. Its really not hard it just takes several hours to do. Hope this Helped Thanks for Watching & SUBSCRIBING
@desisat1
@desisat1 13 дней назад
@@spaman5440 Thanks for prompt response. Can you please share the required tools for the replacement with link. Highly appreciated your support
@blackboxmobile7106
@blackboxmobile7106 14 дней назад
Amazing ... Saved so much time and really the best advice.
@spaman5440
@spaman5440 13 дней назад
Thanks for Watching & SUBSCRIBING
@popularmechanics8617
@popularmechanics8617 14 дней назад
What kind of cement do you prefer when cementing the flex hose back in the fitting you saved?
@spaman5440
@spaman5440 14 дней назад
I clean the area really good with a file and then sand paper... And the Beat PVC Cement Ive found so far is Christ"s Red Hot Blue Glue.. Pro tip: Clean ,Glue, and let it set up and dry for 24 hours. Thanks for Watching & SUBSCRIBING
@libertyhawq1766
@libertyhawq1766 14 дней назад
You saved me today Brother! Plunger worked first time and 💥! Jets working again! First time I ever had this air lock problem and you saved me!
@spaman5440
@spaman5440 14 дней назад
That is fantastic...Glad to help Thanks for Watching & SUBSCRIBING
@jasonpoot5751
@jasonpoot5751 15 дней назад
Hi SpaMan, I’m having trouble with my VS300 Balboa spa pack in my hot tub. I have no display on my topside when I turn power on. Also light comes on and the pump starts without going to prime start up sequence. Has a burning smell from pump area as well then everything shuts off. What do you think is wrong ? Thanks
@cottydry
@cottydry 16 дней назад
Is there any reason the GFCI can't be in the main panel vs sub panel and use a disconnect box as the subpanel?
@spaman5440
@spaman5440 16 дней назад
You can put the GFCI in the main or a Spa disconnect box. Now I always have two breakers on every install I've ever done or helped and Ive put the GFCI in one or the other... I have never just put a GFCI in the main with a disconnect that was not a breaker . I do not like the disconnect like what is used on an AC for instance. Hope this Helps Thanks for Watching & SUBSCRIBING
@cottydry
@cottydry 16 дней назад
@@spaman5440 Thank you! I'm the second owner of a home built in the early '90's and I recently replaced the original hot tub. The original wiring is simply a non GFCI breaker in the main panel and about a 75' run of 8/3 cable. It's a very harsh ocean cliff environment and I can't use anything metal outside unless it's stainless steel or plastic. I really want to rewire this installation to ensure it's safe/proper. Your videos have given me the foundation to redo this wiring the right way.
@spaman5440
@spaman5440 15 дней назад
@@cottydry The 8/3 is the wrong size and type of wire to use outside or on any Hot Tub... I use THHN or THWN wire only #6 on all four wires. Our company fixes this type of problem all the time.... You also need to have a Spa disconnect with in 20 feet of the hot tub and no closer then 5 feet and a min of 36 inches off the ground. Hope this Helps and Thanks for Watching & SUBSCRIBING
@AG-kr6zq
@AG-kr6zq 19 дней назад
Thanks for a helpful video
@Joeykostenbader74
@Joeykostenbader74 19 дней назад
could you spend more time on the Balboa 54381 I seriously dont mind venmo you for services or advice . i got a customer wired it themselves and fried 2 boards i believe he wired the same . On the board between its a viking VKV502 its burnt on the board between w7and the slow blow fuse .
@spaman5440
@spaman5440 17 дней назад
I would need to see how it is wired... The fact that two boards have been fried tells me it is wired wrong. in cases like this I always start with the main checking wiring / breaker then move on to sub disconnect and again make sure everything is wired correct then move on to the pack In the pack I would disconnect every thing I have ways in the field to check motors and I would check them first to make sure they are good. The fact that two boards fried tells me something was done wrong. Hope this Helps Feel free to call the office and talk to Scott to see his thoughts. Thanks for Watching & SUBSCRIBING
@Joeykostenbader74
@Joeykostenbader74 17 дней назад
@@spaman5440 Thank you for the help , I agree what i can tell is they mis identified the plug for the pump2 he landed it on the Circ pump not the Pump2 the spa does not have the optional Circ pump installed. so it had to have been the issue. Im going to ohm out the motors and see if they are dead short or open , but yes i ordered him a new board to replace the other 2 he burnt up . Thank you again i hope others can benefit of these comments.
@Sean-rj4nj
@Sean-rj4nj 20 дней назад
I have a Caldera Hot tub I tried the toilet plunger I couldn’t get the plunger method to work. I took out the filter & placed the plunger on the stem assembly that the filter slides down onto. My Hot Tub was working prior to refilling it back up. So it’s clear it has an air lock or something. I was just looking for help for Caldera Hot tub trouble shooting.
@spaman5440
@spaman5440 19 дней назад
Make sure all the jets are open and the diverter valve is in the middle and the plunger should work… if not you can take the side off and find primary pump one and crack open the the pump and this will work also… now for the bad part of you open it up to much and the O-RINGS gets pushed out you may half to empty and fix o ring and start over… Hope this Helps Thanks for Watching & SUBSCRIBING
@Sean-rj4nj
@Sean-rj4nj 19 дней назад
Thanks for the reply back I do appreciate it. I tried again the toilet plunger still nothing. My Caldera Spa has a stem where the filter goes on so the toilet plunger can’t suction out because of the stem design of it. My hot tub doesn’t have a diverter valve on the top area of my spa the only controls in a valve situation is turning on & off the jets to the seated portions. So unfortunately, it’s something that’s gonna have to be troubleshoot through taking off the control panel. I tried sticking the garden hose down the stem where I removed my filter, turned it on full blast, even tried that nothing worked.
@DavidKingmasterWV
@DavidKingmasterWV 21 день назад
You know your stuff about hot tubs
@DavidKingmasterWV
@DavidKingmasterWV 12 дней назад
The sound of freedom
@Doormaster77
@Doormaster77 21 день назад
I have an older Hot Springs Jetsetter that I'm converting to 220/240v. I have the new wiring in place but do I need to change the dip switch settings? The wiring to the terminal block looks to be from the breaker to go to black wire to #2 white wire to #5 and ground to ground bar. Where does the red wire go? Is there any white wire to remove as you've shown on the balboa?
@JohnStuart-g8t
@JohnStuart-g8t 22 дня назад
This is a great video - very complete and saved me a lot of time and money … thanks for posting it! Keep up the great work
@virginieericdf5858
@virginieericdf5858 22 дня назад
hello, I am in France and owner of a j335 jacuzzi from 2015. I have an FL1 code. the massage pumps work but the circulation pump does not. the fuses are ok. Should the circulation pump be replaced? thanking you for your help.
@PaulPatMcGarry
@PaulPatMcGarry 23 дня назад
Thanks so much for making this video. We were able to change out the heater and are now back in business!!
@gman504ification
@gman504ification 23 дня назад
I have a circuit board that I'm unable to identify can you help me ?
@Livefreewhileucan
@Livefreewhileucan 24 дня назад
Nice video
@Freshflesh666
@Freshflesh666 24 дня назад
Remember when this guy got sued lmao 😂 spa man got spa slammed
@DavidSlusar
@DavidSlusar 24 дня назад
Can you use a jacuzzi pak to wire.
@DavidSlusar
@DavidSlusar 24 дня назад
Hey Spa man can you show what color wires go where in the sub panel breaker please
25 дней назад
Great video. My hot tub breaker trips intermittently. Stays on for hours then when we go to use the breaker is tripped. Any Ideas?
@spaman5440
@spaman5440 25 дней назад
Check your connections Thanks for Watching & SUBSCRIBING
25 дней назад
@@spaman5440 I have checked all connections and even replaced the GFCI breaker. I am leaning toward the circulation pump overheating over time, or am I off track. I think if it was the heater element it would trip right away.
@high.tened_sense5966
@high.tened_sense5966 27 дней назад
Great vid! Does this work on a hot tub with Two pumps?
@spaman5440
@spaman5440 27 дней назад
Not really sure what you are asking... A hot tub with two pumps and motors 99% of the time has to be wired 220/240 volt hard wired. Hope that Helps ...Thanks for Watching & SUBSCRIBING
@high.tened_sense5966
@high.tened_sense5966 26 дней назад
@@spaman5440 sometimes not knowing enough means not knowing the right questions to ask, so I am sorry for the confusing question I asked. I guess what I am trying to find out is, my 220v hottub has 2 pumps, so do I have to run 2 separate 220v circuits (220v circuit per pump) or will the one main 220v circuit power the tubs two pumps
@DavidKingmasterWV
@DavidKingmasterWV 28 дней назад
You are very good at what you do but why do you call a neutral a coman and a disconnect a sub panel?
@JavierMunoz-gy9sn
@JavierMunoz-gy9sn 28 дней назад
Hey Scott, what is the black box behind the pack? It's leaking on me.. is it my circulating pump?? Please help!!
@spaman5440
@spaman5440 28 дней назад
Not sure .. Cir pump is small and about the size of a grape fruit Ozone is a black box and is sometimes mounted to the side of the pack. Post a Pic of it Thanks for Watching & SUBSCRIBING
@JavierMunoz-gy9sn
@JavierMunoz-gy9sn 27 дней назад
@@spaman5440 okay so it's not the circ pump, there is a 2" clear tube uniting the pump to the pack and it's that small black box that is leaking...
@spaman5440
@spaman5440 27 дней назад
@@JavierMunoz-gy9sn I thing that it is your Heater and if it is leaking it will need to be replaced . If that is the case its not a really hard fix just take a lot of time and you have to take special attention so you don't break other part while removing the heater . Sometime now is a good time to replace some items that need replacing after many years of service you are there and have to remove several parts and it will save you time and money in the long run... If your in Az and need Help call our off ice and we will do the repair for You Thanks for Watching & SUBSCRIBING
@tarhunta2111
@tarhunta2111 29 дней назад
Thanks buddy.That nearly broke my balls trying to figure it out.
@spaman5440
@spaman5440 28 дней назад
LOL me too until I figured out everyway to make one go away. Thanks for Watching & SUBSCRIBING
@dunasingh8653
@dunasingh8653 Месяц назад
How and what kind of material do you use to re-form the big big hole? Thanks.
@dunasingh8653
@dunasingh8653 Месяц назад
Just curios, why don't you use the silicone caulking instead of PVC?
@Babygrand98
@Babygrand98 Месяц назад
What about the hole drilled in hot tub to run conduit? Did you seal it with grommet or something?
@marcenglish9
@marcenglish9 Месяц назад
Can anyone help? I need to replace the control board on my spa. It's a Leisure Bay G2 plus super duplex. 2 pump spa. The board S/N is 52326. The chip number is G2R1B. This board is not in production anymore. Can someone help me find a replacement that will work??? Please
@spaman5440
@spaman5440 Месяц назад
Call the off ice a nd talk to Scott... Thanks for Watching & SUBSCRIBING
@marcenglish9
@marcenglish9 Месяц назад
@spaman5440 I talked to a guy online. My system is actually a 1 pump but he said I needed to do a retrofit and recommended the Gecko YE5
@nanolomb
@nanolomb Месяц назад
Excellent video! Thanks!
@RubenMendoza-q3e
@RubenMendoza-q3e Месяц назад
Nice i like
@jenniferholstrom3790
@jenniferholstrom3790 Месяц назад
Hey Spa what does the other end of the power cord
@jenniferholstrom3790
@jenniferholstrom3790 Месяц назад
Look like? I am trying to do a plug n play on my spa.
@jasondidcott445
@jasondidcott445 Месяц назад
Fantastic video - thank you.
@StevenBanks123
@StevenBanks123 Месяц назад
thanks. Video could do with some speeded up sections.
@doughilling5355
@doughilling5355 Месяц назад
spa man. question I have the exact Gecko controller and its tripping my 50a breaker. I've disconnected the pumps, heater and it still trips. I checked both incoming wires Red/Black and both read 121V. If all devices are unhooked from the controller and it still trip? Does it mean the controller is bad?
@garyredmond9275
@garyredmond9275 Месяц назад
would a 6 inch flex hose be long enough to heat up get a coupler in between?? I currently have a rubber boot with clamps in between two hard pipes. Not sure if it will hold
@chriscadman8320
@chriscadman8320 Месяц назад
What about motor for pump doesn’t it need to be rewired too?
@keithhorton3905
@keithhorton3905 Месяц назад
Thanks so much for sharing your knowlwedge, video worked a treat- all the best from the UK 👏👏
@dannyhowell3171
@dannyhowell3171 Месяц назад
I really like these videos,but I wish there is a place to ask questions about my old (2002) Vita hot tub. It was given to me and I don't know anything about it. High limit code
@spaman5440
@spaman5440 Месяц назад
Call the office and ask for Scott ... He will be able to help you. Thanks for Watching & SUBSCRIBING
@Smil3y7021
@Smil3y7021 Месяц назад
Does this work if only one section isn't working?! Can't seem to figure it out
@spaman5440
@spaman5440 Месяц назад
As long as you can cover the filter inlet and get a good seal and all of the connection are tight...I will work every time. If it doesn't work you could have something else going... Thanks for Watching & SUBSCRIBING
@johnchamichyan
@johnchamichyan Месяц назад
Who went in your tub lol
@bubba99009
@bubba99009 Месяц назад
I wish there was a better aftermarket heater - it is such a lousy design and not a good quality part. I just replaced mine with a supposedly OEM one and one of the temp sensors that came in it was DOA and out of spec so it would throw a temperature probe error. I was able to use the ones from the bad heater which worked. Now a few months later the new heater is tripping the GFCI again. That electrical connection on the heater is such a bad design too. I had to grind down a wrench to hold the stud because you have so little room. Guess I'll buy another one and hope it is a better unit.
@spaman5440
@spaman5440 Месяц назад
Sorry to hear you are having so much trouble.. In all of the years that I have been doing Spa repairs Balboa is by far one of the best designs on the market. So I see this all the time with home owners You might of bought the wrong heaters with the wrong sensors. A lot of DIYer think they are buying an OEM part when in fact it is an after market part sometime you get lucky sometimes not. As for the electrical connection... Make sure you put the washer on the right side of the connection and they make a special 1/4 wrench for that task. I never use aftermarket parts because of the problems you are having Thanks for Watching & SUBSCRIBING