Welcome to Kinco Automation's RU-vid channel! We create informative and engaging videos on our products and services to provide businesses and individuals with the knowledge and tools they need to be successful with automation technology. Our channel features product showcases, training videos, problem-solving solutions, and online support from our experts. Subscribe to our channel to join us on our journey to revolutionize the world of automation!
buen dia. estoy haciendo un proyecto con un PLC-HMI KINCO para activar una salida PWM con una frecuencia de 20khezt y aunque en la simulación si activa el bloque de PWM, y utilizo los registro de periodo y ciclo útil al grabarlo la salida no me manda la frecuencia que necesito, solo funciona para frecuencias bajas, menores de 1khrz. como hago para activar para periodo en us y frecuencias altas?
buen dia. estoy haciendo un proyecto con un PLC-HMI KINCO para activar una salida PWM con una frecuencia de 20khezt y aunque en la simulación si activa el bloque de PWM, y utilizo los registro de periodo y ciclo útil al grabarlo la salida no me manda la frecuencia que necesito, solo funciona para frecuencias bajas, menores de 1khrz. como hago para activar para periodo en us y frecuencias altas?
buen dia. estoy haciendo un proyecto con un PLC-HMI KINCO para activar una salida PWM con una frecuencia de 20khezt y aunque en la simulación si activa el bloque de PWM, y utilizo los registro de periodo y ciclo útil al grabarlo la salida no me manda la frecuencia que necesito, solo funciona para frecuencias bajas, menores de 1khrz. como hago para activar para periodo en us y frecuencias altas?
BUEN DIA ME PODRIAS AYUDAR CON UNA FALLA EN UN ENCODER (AL-41) DE UN SERVO MOTOR MODELO 80ST-J02430LB(X) QUE TIENE UN CNCSERVOCONTROL AASD-15A-V6.3, TE AGRADECERIA SI ME PUEDES AYUDAR, YA HICE PRUEBAS CON OTRO SERVO MOTOR Y SI TRABAJA TODO BIEN PERO EL QUE ME MANDA FALLA NO LO PUEDO HACER FUNCIONAR
Hello, is it possible to make SQL queries using the Database query component? I'm trying, but I only get errors, and after trying to make a query the writing starts to fail too.
Hello, I have a question regarding VNC I am using VNC to view the HMI from my phone and everything works correctly, but when I disconnect from VNC and connect after a few hours, the HMI stays offline and takes 3 or 4 minutes to connect to VNC again. Do you know why? Is there no way to always keep the HMI online?
In the test email function, it works to receive emails, but when I set it to send historical data it does not send the information through the HMI. What can I do in this case ? It is necessary for the HMI to receive an IP via DHCP or this email feature works with a fixed IP ?
Hi, When I enter Google Chrome and type <my_ip>:5800. The result of the page is "File Not Found". I need monitoring through "Remote control by browser". Help Me. HMI GL070E.
I have: Kinco PLC K606-24DT and Kinco AC servo FD422 controller. 1) How to hard reset this servo controller (to factory settings)? 2) How to program communication with the PLC controller via RS485? (I have the connection, I need an example program in the LADDER language - a simple forward and backward movement program) I can't find it anywhere on the internet. Please help.
There are 3 GL070E. One of them will be the master and the other two will be slaves. Slaves only copy the master. In other words, whatever happens to the master, the same will happen to the slaves. The slave will only monitor. Can you make a video about this or help?
We also are trying to use the email feature for events but although the test mail is working, during an event, it doesn't send anything even in latest update is 4.3.0 v. can you help to rectify? GL070E used model
Yes, update lastest software,HMI attributes, e-mail setting is there. Here you can add contact list and also define Register address for email settings
@@KincoAutomation I understand the meaning of torque control well, but it seems the motor rotation speed is higher than what is expected for a frequency of 0.05 Hz.
hi! for me, in event display letters are smooth and nice, but in alarm display, they’re sort of pixelated and rough. readable, but clearly something’s wrong there. is it normal or am I missing something? I also noticed that if I remove background from the event display, letters become pixelated in there as well.
The DTOOLS software was updated to version 4.2.0 to use the email sending feature. Even following the step-by-step instructions shown in the video available on Kinco's You Tube account only works in the TEST function. When I use it for the screen shot it is not working. What would Kinco recommend to resolve this issue?
Nice Job!!! I have a Kinco-MK070E HMI-PLC and I would like to know how I can program a bit state (button) to connect with an output at HMI-PLC (standalone) without another PLC.