Careers360 is one and only high-tech Trainings and Development center in Pakistan, we provide advanced & expert level Engineering Trainings as per Pakistan and International market need. With 100& placement assistance in local and international market. VISION We envision in DELIVERING SUSTAINABLE HUMAN CAPITAL FOR THE FUTURE
MISSION Our mission is to design and deliver high impact development programs and a wide range of consultancy services that produce outstanding human performance in your organizations and individual’s.
GUIDING PHILOSOPHY We are committed to create a strong and continuous improvement in human capital performance with your organization and individual’s.
For More Info, JOIN US Call +92-300-4336502 WhatsApp +92 331 4081886 Email info@careers360.com.pk www.careers360.com.pk RU-vid ru-vid.com/show-UCpgssSe6A9p1357WzfLbNgg LinkedIn lnkd.in/dhmJVvf Facebook link lnkd.in/d2WPRuc Tweeter @CAREERS3602 Instagram Careers.360
Yes possible, if you use DSE P123 load share line with DSE8610, P123 load sharing interface for third party load sharing. The second option is to install one DSD8610 with 3100 ,
@@careers360-PK thanks sir, i have 4 unit cummins genset preventive maintenance, the controller all pcc 3100, the one is damage, recommendation is to replace a new pcc 3100 but is very expensive
Can you tell me if we have Cummins engine with its EFC Governor and MPU set... And then we want to change the governor with a different brand, will that new governor of different brand be compatible with cummins actuator?
And one more question, Our DG capacity is 900 Kw and we gave some small loads like AC, lights, PC about 10 KW, DG was running fine with normal parameters. We plan to start one 75 KW motor with DOL starter then DG gets tripped on under voltage and under frequency. Please advise
Hi , we are using the same governor and controller here. Our DG frequency is just 49.17 Hz. How to raise the engine rpm through the Deep sea controller ? Please advise
@@careers360-PK Yes deep sea output is already connected with DC6 governor. And the setting of nominal frequency is 50 HZ in deep sea however the engine is running only 49.17 Hz , 1475 rpm only . I want to raise the rpm and frequency. Can I raise the rpm with deep sea 8610MKII configuration software? . I am seeing in your video that you are adjusting the rpm through the deep sea software governor page of DSE 8610 MKII Scada . Is DSE8610 MKII configuration and DSE8610 MKII Scada both are the same software or I should download separately!
Yes you can raise the speed from 8610 software, if DC6 analogue input activated from DC 6 henzmann software, if that in put disabled then you can't, Yes DSE configuration and SCADA both are different software
@@careers360-PK Noted sir. I have DSE8610 configuration software already. So I should download DSE8610 Scada software ? Could you please ping me the download link
I have connected with DSE8610 Scada page. However I am getting only AVR option over there not Governor option. Please advise to get GOV option . Our engine running only 49.17 Hz only. I want to raise the engine rpm. Pls advise sir
Aslam u alaikum Air mara question hai kh jbh hum 2 ya 2 sy zyada gensets ko synch krty hay sharing krty hay to 2 controllers ki sharing krwany k liay kon kon sy parameters check krny hay or MSc link ko joint krty hoay kitny ohm ki resistance use krty hay
میرے دوست یہاں پر سسٹم کے ساتھ بھی ویڈیوز اپلوڈڈ ہیں ، اپ کو مل جائیں گیں ، اور دوسری بات یہ ہے دنیا کا سب سے آسان کام تنقید کرنا ہے ، یہ ویڈیو ہر کسی کے لیے نہیں ہیں ، صرف ان لوگوں کے لیے ہیں جو 8610 کو تھوڑا بہت سمجھتے ہیں یا اس فیلڈ سے وابستہ ہیں ، اپنا خیال رکھیں ، شکریہ