EDC Assembly Guide
2:20
3 года назад
CO2 Monitoring - Why?
3:28
3 года назад
Safety Communicator
5:19
4 года назад
Introduction to the Watchgas Neo PID
11:20
4 года назад
12 Days Of Christmas Free Shipping
0:27
4 года назад
Safety Monitors
0:26
5 лет назад
Safety and Health Expo is Here!
0:18
5 лет назад
Calibrating a MultiRAE
4:27
5 лет назад
Changing Sensors on the MultiRAE
4:35
5 лет назад
Who are Safety Monitors?
1:59
5 лет назад
The Safety Monitors Proposition
0:58
6 лет назад
Комментарии
@Dean-gi8ie
@Dean-gi8ie 5 дней назад
Howdy I'm a little late I know, but if anyone still active here how do I fix "VOC span error"
@calvinblackrosejr4890
@calvinblackrosejr4890 27 дней назад
Excellent video!!! Thank you
@boatengmaxwell6292
@boatengmaxwell6292 29 дней назад
Please I need your contact for assistance.
@KatecrochetInvan
@KatecrochetInvan Месяц назад
Hi, sorry but I always find the O2 sensor in the center. Is it wrong?
@dredwine116
@dredwine116 2 месяца назад
These are dog shit devices. How do you turn them off? They go off continually with no way to stop them. Absolute pieces of shit.
@Rafael-tc2rh
@Rafael-tc2rh 4 месяца назад
I agree, I really couldn't hear clearly do to the loud music😢
@zeenat_mujeeb2806
@zeenat_mujeeb2806 4 месяца назад
Hey my vibration meter isn't giving wifi to my mobile so that it could be connected with mobile to run L D atlas aap, and take vibration measurents, sir how to fix this issue? Is there any option to reset the vibration meter such that It will again show hotspot and connect my mobile with it via wifi?
@HummingbirdCyborg
@HummingbirdCyborg 5 месяцев назад
Mine started going off back at our fire station. It would fail to calibrate, but just make loud noise for no reason.
@marcelolandeiro1153
@marcelolandeiro1153 7 месяцев назад
During the calibration procedure, everything progresses according to the instructions until the equipment performs the zero. At this point, instead of receiving the expected message to apply gas, I am presented with the indication "Closed."
@greedytoski
@greedytoski 8 месяцев назад
what for you put a music in the video ??? one hardly can hear what you speak!
@armandogaitan2655
@armandogaitan2655 11 месяцев назад
Do this have a charging indicator light when charging?
@SafetyMonitors
@SafetyMonitors 11 месяцев назад
No but there is an indicator on the screen showing the state of charge and the battery indicator
@reydagzTV
@reydagzTV Год назад
What's that buzzing sound?
@SafetyMonitors
@SafetyMonitors Год назад
That's the pump. There are 2 versions of the unit one diffusive (this passively responds to gas) and this version with a pump. The pump allows for pre-entry testing with a probe and faster response times on the gas sensors.
@reydagzTV
@reydagzTV Год назад
@@SafetyMonitors can you recommend me a good version I mean a user friendly one (easy to use)?
@SafetyMonitors
@SafetyMonitors Год назад
What is the application? If you visit our website you will find a great deal of 4 gas monitor options@@reydagzTV
@luismartinezjr6460
@luismartinezjr6460 Год назад
Does this monitor automatically turn off after a certain amount of time
@abhijitsantusaikia
@abhijitsantusaikia Год назад
What that mean by cal failure, after that the screen shows cal dur 12 1 d means
@SafetyMonitors
@SafetyMonitors Год назад
The 121 d signifies how many days until full calibration is due according to the settings on the unit. This will usually be a recommended frequency of every 180 days depending on your setups, regional and company requirements. In terms of the cal failure on start up this is usually because of the O2 sensor. When the unit first starts up it does a fresh air calibration on the Oxygen Sensor. If you are getting the calibration failure message at this point it’s usually because the O2 sensor has failed to calibrate correctly to fresh air. This can be for a variety of reasons, maybe a faulty or old O2 sensor that needs replacement but could also be due to low battery condition on the unit so there is enough to start it up but not enough current flowing through the sensor at start up for it to correctly automatically calibrate. If you are still finding the error after a full charge I would recommend returning to an Authorised Honeywell service centre such as Safety Monitors in the UK or a regional Authorised centre if outside the UK and Ireland. I hope that helps.
@kamilviper1993
@kamilviper1993 Год назад
Can i close the calibration blinking without calibration? Im outside the laboratory :(
@SafetyMonitors
@SafetyMonitors Год назад
I am afraid not when it is overdue that indicator will remain until it is calibrated both zero'd and span'd.
@giottino69
@giottino69 Год назад
Hello, thanks for the video, have you got one pumped? when the alarm of pump is on, what I can do for reset it? thanks!
@SafetyMonitors
@SafetyMonitors Год назад
The unit shown is a pumped model, if you need to reset the pump after a blockage acknowledge the alarm with a Y button this will then restart the pump, if the blockage remains I am afraid it will not restart. You will need to send the unit in to a service centre for works if this is the case and you can't locate the blockage on the front filter as it may have debris within the pump. Hope that helps
@jennifercleveland2344
@jennifercleveland2344 Год назад
Can results be accessed via Blue Tooth ?
@SafetyMonitors
@SafetyMonitors Год назад
There is a bluetooth adaptor you can get for the Microclip which will give you a live view via mobile app however this will not download any data. If you need that functionality you would need to look at the BW Icon or BW Flex instruments which have come more recently. The data is also limited to 35 events it doesn't have full data logging.
@jacquestanner2367
@jacquestanner2367 Год назад
What does TWA mean?
@azizsahar9817
@azizsahar9817 Год назад
Time weighed average
@arlonraysalig5182
@arlonraysalig5182 2 года назад
how to change the time and date of this gas monitor
@artaraiza4559
@artaraiza4559 2 года назад
It’s really hard to listen with that music on the background lol
@NAKMEEZY
@NAKMEEZY 2 года назад
How often should a meter be calibrated? I think the operator is playing games with us.
@VictorVictor-hq7ui
@VictorVictor-hq7ui 2 года назад
Turn the annoying music off so we can here you better.
@aubreyclements8201
@aubreyclements8201 2 года назад
Your equipment is trash!! The video is not helpful what so ever. There is no way to turn it off!! The stupid thing is going off even after a zeroing it out. I hoped by watching this there would be a way to shut it off and there isn’t!! The best place for the 4 gas monitor is the trash!!
@cussmustard4748
@cussmustard4748 2 года назад
I left my job because they implemented this garbage. It was never about safety, only about having more control and oversight. The tighter you grasp, the more that slips between your fingers.
@TEXASpatriot76
@TEXASpatriot76 Год назад
My company handed them out today. However they have so many ways of tracking our every moment so that's not a big deal with this. It's just bulky I hate that
@Patrick-qi3ws
@Patrick-qi3ws 2 года назад
Thank you. Great video
@user-pd8vq6gc7r
@user-pd8vq6gc7r 2 года назад
ج ماسم هذا الجهاز بالعربية
@darwinpaez3892
@darwinpaez3892 Год назад
Me podrían enviar un vídeo en español.!
@matthewsparks1288
@matthewsparks1288 2 года назад
☺️ Promo`SM.
@scottworth6697
@scottworth6697 2 года назад
How do I fix an operational error?
@SafetyMonitors
@SafetyMonitors 2 года назад
Unfortunately it is likely to need to head to a service centre. If you are based in the UK send in to us and we can take a look. If it is still within it's 2 year life it will be covered under warranty.
@poscbr600
@poscbr600 2 года назад
Stupid f-ing music
@imamuadinani5321
@imamuadinani5321 3 года назад
Helpfully thanks
@Hekkietoir
@Hekkietoir 3 года назад
Brilliant guy
@festusuyi5040
@festusuyi5040 3 года назад
Thanks so much for the video. But how do I disable the alarm unit?
@SafetyMonitors
@SafetyMonitors 3 года назад
You can disable the audio alarms via the menus, you access these by pressing the Mode and N buttons then go to alarm setting and you should see an option to disable the audio and visual alarms, I wouldn't recommend this outside of some specific applications however as these are there to protect you and your colleagues. You can also do this by connecting up the unit via the supplied serial cable to a PC and use the free ProRAE Studio 2 software to change a variety of settings, this is often easier and more intuitive, just download the software from raesystems.com and then connect up the unit, enter data manager mode password is rae. Then download settings, update what you need and send the settings back to the unit. The last bit is important, if you don't send the settings back to the unit it won't be stored. I hope that makes sense and helps.
@festusuyi5040
@festusuyi5040 3 года назад
@@SafetyMonitors Thank you so much,I'm going to get on it.Appreciated
@SafetyMonitors
@SafetyMonitors 3 года назад
@@festusuyi5040 No problems if you need any help, new units or servicing let us know as we are a full service centre for RAE/ Honeywell. Just email info@safetymonitors.co.uk
@ezdayz9871
@ezdayz9871 3 года назад
Really useful video thanks
@Fetherko
@Fetherko 3 года назад
He has an accent and you run music to make him less intelligible.
@manumutango8863
@manumutango8863 3 года назад
Very good, i appreciate this video
@saulosantos8454
@saulosantos8454 3 года назад
Nice video. No worries about the music, I liked heheh Thank you so much Best regards from Brazil
@mobroed
@mobroed 3 года назад
Would it be possible to repost this without the background music being louder than the person's voice?
@spke1
@spke1 3 года назад
Thank you!
@nasimqadir159
@nasimqadir159 3 года назад
Well this is a very use full video as well as other brand but requested to you pls screen display need to should be very very promenent at the time of briefing / Training when you making video NQ
@wendycatherineortegap.9895
@wendycatherineortegap.9895 4 года назад
hi, could you translate it into spanish?
@rodentrancher
@rodentrancher 4 года назад
Very nice, thank you. Couldn't find this information on Honeywell's own site, thoughtful of you to post it to RU-vid.
@hoangmaize5723
@hoangmaize5723 4 года назад
Ai ở VN mà quan tâm có thể ghé qua: gascliptech.com.vn/
@hoangmaize5723
@hoangmaize5723 4 года назад
Bạn nào ở Việt Nam mà quan tâm thì có thể ghé qua xem thử: gascliptech.com.vn/
@clydecossette1846
@clydecossette1846 4 года назад
Worst instructional video ever. Can't understand the narrator, music is annoying and he knows the thing so well, and talks too fast, that as a beginner I am lost.
@ezdayz9871
@ezdayz9871 4 года назад
There are some updated videos on our channel, this was from the very early days of the company and we have done some shorter videos. We appreciate there are some issues with some of our older videos including this one and we are currently recording some full updates. If you need any direct help do let us know you can email info@safetymonitors.co.uk or call +44(0)1489 326031
@RTC363
@RTC363 4 года назад
You mention the Icon + has eight sensor options, but the datasheet only shows five (CO, H2S, O2, IR LEL and SO2). What are the other three sensors the Icon + can detect?
@SafetyMonitors
@SafetyMonitors 4 года назад
Ryan Cantwell the options are not available from launch they are on the way more details to follow.
@muhammadrafiqasim4837
@muhammadrafiqasim4837 4 года назад
I need this gas detector price plz????
@bryanhoggatt1339
@bryanhoggatt1339 4 года назад
Great video! Thanks for putting it up! Just a quick note for anyone using this dock: The data logs are downloaded between when the Unit light turned green, and when the power light turns green. If you leave the monitor on the dock until the power light turns green, the logs will be downloaded and the dock will purge the gas from the monitor with fresh air, preventing it from going into alarm as it did in the video.
@0856010
@0856010 4 года назад
Thanks for the video! But I have to say that the music at the beginning is too loud, it just killed my ears! :)
@thanhtranpham2222
@thanhtranpham2222 4 года назад
The value of the smart charging download's current and voltage?
@k.bercero2921
@k.bercero2921 4 года назад
Can i use the device after receiving it, or i need to load gas on it? Thank you
@SafetyMonitors
@SafetyMonitors 4 года назад
It depends who you purchase from. From us it would come calibrated and ready to go and just need another calibration in 6 months.