Тёмный
GPSTC Productions
GPSTC Productions
GPSTC Productions
Подписаться
This is the official RU-vid channel of the Georgia Public Safety Training Center (GPSTC).

GPSTC is Georgia's premier training facility for all state and local public safety-related units of government including police officers, firefighters, 911 operators, coroners, emergency management officers, rescue officers, jail officers and other emergency service personnel.
GPSTC is hiring!
0:59
2 года назад
Governor's Initiative Courses Promo
1:43
2 года назад
First Responders Day
1:00
3 года назад
What You Don't Know - Katie and Wesley
18:05
3 года назад
What You Don't Know - James and David
13:50
3 года назад
Sex Trafficking Course Promo
1:01
4 года назад
Handling TTY Calls Course Promo
0:40
4 года назад
Online Learning Options
1:30
4 года назад
PTSD Awareness Month
1:42
4 года назад
What You Don't Know - The Cooper Family
28:30
4 года назад
Start the Conversation Trailer
1:51
5 лет назад
Milestones to Headstones
12:25
5 лет назад
Start the Conversation
52:45
5 лет назад
Motorcycle Crash Test at the GPSTC
4:57
9 лет назад
Firearms on the GPSTC Campus
2:45
10 лет назад
Pressurized Container Fire Control
2:07
11 лет назад
Комментарии
@tewksburydriver8624
@tewksburydriver8624 24 дня назад
How can you tell what system it is? Does the panel say addressable on it?
@justinives5890
@justinives5890 26 дней назад
Incredible
@nubian47
@nubian47 Месяц назад
Well done 👍
@Fredengle
@Fredengle Месяц назад
here is a question for you as you probably know in new installations anti freeze is frowned upon it seems possilbe that a fire hose can be attached to the sprinkler system so my question to you is could a dry sprinkler system be attached to a fire hose valve to function as a dry hose valve?
@brettrussell1
@brettrussell1 2 месяца назад
do you know how to reset a over the tally limit on a Symplex 4005? Thx
@CaptainGoldberg
@CaptainGoldberg 2 месяца назад
Time to upgrade systems to Honeywell EBI life safety with our addressable panels.
@AngelMichael685
@AngelMichael685 3 месяца назад
Ωραία έκθεση για το συστήμα ασφάλειας
@pjmichaelsrocksyou
@pjmichaelsrocksyou 4 месяца назад
Good video
@noahDhe
@noahDhe 4 месяца назад
Do you have to notify fire department when you do main drain test?
@angel0254
@angel0254 3 месяца назад
No sir your system should be on test and it won’t notify the fire department always have it in test.
@JGregPike
@JGregPike 4 месяца назад
Definitely struck a chord. Been at it since '87 and some of the memories are hard. Thank you sir!
@antoinem5901
@antoinem5901 4 месяца назад
I liked when he put trouble on the fire alarm 1:42
@user-pf9ly6kh4w
@user-pf9ly6kh4w 6 месяцев назад
Excellent I met Griff years ago and was so impressed i just seen him again at a seminar in Ulster County it was Great
@DH-og5yr
@DH-og5yr 6 месяцев назад
Where we are, valve switches, supervisory on the panel, are latching, in that they do not clear when the valve is reopened.
@sherricka162
@sherricka162 7 месяцев назад
🙏💯 great story
@CarlosGuzman-pz1jr
@CarlosGuzman-pz1jr 7 месяцев назад
Thank you for your time doing this video. More or less, how many sprinklers could be installed by alarm check valve like that ? for K=16 3/4" sprinklerc type? Thank you in advance
@kiltripxv1
@kiltripxv1 7 месяцев назад
Very articulate, detailed and to the point. Thanks for the upload, earned a sub.
@zaitonyahya4768
@zaitonyahya4768 8 месяцев назад
Tuah research sdn bhd
@dylann2038
@dylann2038 8 месяцев назад
Good video
@user-vz6nh4rx5b
@user-vz6nh4rx5b 9 месяцев назад
I want one or two days classes of fire alarm installation
@mychannel8809
@mychannel8809 4 месяца назад
Me too
@aztekaa1
@aztekaa1 9 месяцев назад
Thanks for the video
@sebastiannielsen
@sebastiannielsen 9 месяцев назад
Of course, if you wire multiple detectors on a "zone", they are not gonna know which one tripped it. But if you have a conventional system, and you wire only ONE detector per zone, you get no problems. If you want to reduce wiring, you can use "zone expanders", which are devices that usually communicate via RS485, that will reduce wiring. Another way to wire it, is room-based. Wire zones so all detectors and pull stations in a room is on one zone. It makes it easy for everyone including firemen, to know where something happened, and once you have visual sight with that room, it will be easy to find out what triggered the alarm. I actually prefer conventional systems for 3 reasons: They are easier to troubleshoot, because anything you do will have an instant effect on the system. As you saw, that detector you removed took a whole minute or two before the panel even knew about it. The conventional reacted in a instant, thats because the current flow in the loop ceased and kinda instantly woke up the system. The second reason, is that its easy to integrate non-firealarm-equipment into zones. For example burgular alarm, you might want to interconnect it with a burgular alarm, either to share reporting channel, or to switch between "Remote mode" and "Local mode" depending on if the burgular alarm is armed or not. With that, I mean, when people are present, it might be stupid to send the alarm instantly to the fire department, since the fire could be dealt with locally. It could just be some failed cooking that wasn't even a fire, someone already at the stove that reacted immidiately when that pot started to smoke. So thats why it could be good to have a system that is "local" when people are present, and "remote" (send a instant alarm to fire department) when the burgular system is armed and the building is clearly empty. the third reason is the vendor lockin. A conventional system can accept fire detectors from any other conventional system. You aren't locked in to one manufacturer of detectors. If you choose a adressable system, you need to purchase everything from the manufacturer of your panel. That could be advantageous in some cases, so you know everything works together, but the disadvantage is that you might have a duct detector that is shipped along with a HVAC system nicely integrated, and then you can't use it because you don't have THAT vendor of panel.
@kevin00861
@kevin00861 7 месяцев назад
Thanks a lot Sir for sharing your knowledge, Your comment is so valuable and helpful
@DarklordXX904
@DarklordXX904 10 месяцев назад
Insightful
@bobroberts603
@bobroberts603 10 месяцев назад
Great talk. Can't wait to read the book.
@davejackson3869
@davejackson3869 11 месяцев назад
whats that test show? i would think the way u test a sprinkler system is to get smoke near a sprinkler head and see if it goes off? im not understanding
@curonelectricity
@curonelectricity Год назад
I like your video ❤❤❤❤❤
@IanMDent
@IanMDent Год назад
Excellent, excellent, excellent!
@undaya
@undaya Год назад
ok.if you wanted to rearrange some piping ( usually around ac unit ) where we shut water off and drain pipe? Sprinkler people really need to get their pipes up and out of the way. You trying to tell me there is no shut off anywhere?
@TheChampionsPath1
@TheChampionsPath1 Год назад
Great conversation.
@user-ik7kd1by5c
@user-ik7kd1by5c Год назад
Courageous
@johndelaney7533
@johndelaney7533 Год назад
We recently had an inspection done by a local company and they said our Gauges needed to be replaced because they were older than 5 years. Can you make a video on how to replace the gauges?
@YTviewer118
@YTviewer118 Год назад
I'm sure you'd have to get an approved company to replace the gauges, you can't just unscrew and swap them out as the entire system has to be approved and certified to avoid shortcuts..
@Harry_Gurvich
@Harry_Gurvich 9 месяцев назад
Most gauges used on fire sprinkler systems are installed with a "THREE-WAY GAUGE VALVE" (Google it so you can see an image of it). If your gauges have these valves, you can replace the guages without taking the system "out-of-service". Make sure your new water gauges are listed (approved) for usage on a fire sprinkler system. Use teflon tape on the new gauges if they didn't come pre-taped. Don't use pipe dope.
@theelite856
@theelite856 5 месяцев назад
Fire sprinkler technician here technically you your self are not supposed to change out the gauges but if you wanted to just make sure you close the valve right before the gauge then you can remove it or even safer you can close the main valve on the entire system and drain it just make sure to call it in to the central the watches over the building
@RaykingMaster
@RaykingMaster Год назад
This is how test and practice should be done and explain, thanks....
@user-zg7se7kd7k
@user-zg7se7kd7k Год назад
zone system device hs to be returned to normal before reset
@AnaStudent
@AnaStudent Год назад
Why can't the water pressure drop down to zero
@julianneheredia3739
@julianneheredia3739 Год назад
Very well done.
@johng5295
@johng5295 Год назад
Thanks in a million. Great content. Awesome. Very well explained. I couldn't find this explanation--simply put anywhere else. Great teachers are hard to find. Grade: A++💥
@babugandhibose6663
@babugandhibose6663 Год назад
Very useful video thankyou sir 🙏
@layazentman1284
@layazentman1284 Год назад
Hi im an electrician from NJ just got my license and really want to learm these sytems and wouldlike your input. I sthere a way I can PM you so we can talk? Thanks
@candiceangotti4729
@candiceangotti4729 Год назад
Short and sweet, thank you!
@mumtazawan1421
@mumtazawan1421 Год назад
Very good explained. Thank you and, Regards
@leonardoaboy5237
@leonardoaboy5237 Год назад
Can be the conventional be integrated to addressable? Please advise
@Junior_7279
@Junior_7279 7 месяцев назад
not without a fresh install.
@maikamal8567
@maikamal8567 Год назад
Very helpful! Thanks for the trick remembering the difference between SLC and IDC.
@shaikghousepeer6350
@shaikghousepeer6350 2 года назад
What is 2 stage fire alarm system and 3 stage fire alarm system
@MauiWowie51
@MauiWowie51 Год назад
thats not a thing.
@harikarthik6034
@harikarthik6034 Год назад
its actually the impact of fire. If the impact is low first level will be on and likewise
@MauiWowie51
@MauiWowie51 Год назад
@@harikarthik6034 that is not a thing. you just made that up.
@harikarthik6034
@harikarthik6034 Год назад
@@MauiWowie51 ok sorry for that explain ke please
@MauiWowie51
@MauiWowie51 Год назад
@@harikarthik6034 There either is a fire or there is no fire. There are no stages of fire alarm.
@pencilcollector4963
@pencilcollector4963 2 года назад
YAY! PTSD awareness month
@stephenhart6158
@stephenhart6158 2 года назад
in a conventional panel if you had 4 smoke detectors with had leds that had been triggered would they all light up or only one? in an addressable panel does each device have to have a tacked on individual addressable device or does each initiating device incorporate an addressable feature as part of its construction?
@mychannel8809
@mychannel8809 4 месяца назад
Just the one will light up, and each device on an addressable system has a built in end of line. That’s how the panel monitors the troubles and supervisories, the panel is constantly talking to each device in an addressable system and making sure it has the correct voltage.
@LakersNotFakers4
@LakersNotFakers4 2 года назад
Thank you
@missyb4518
@missyb4518 2 года назад
Bullshit
@agneramador4013
@agneramador4013 2 года назад
Esty buscando este trabajo