Let's connect: Feel free to discuss and share construction problems and solutions in the comments. Don't forget to Hit like and subscribe! Thank you for joining the community.
@@knowcivilengineeringwithkundan (I don't have much knowledge about PT elements) But we are not pulling both the outer cables simultaneously. So it could have bend in the First pull itself.
@@knowcivilengineeringwithkundan I'm saying if we pull both the outer cables simultaneously... It will be more balanced as compared to pulling one by one separately. For eg :- carrying loads(equal loads X, X ) in both hands is more balanced than carrying one (same X) load in one hand only
As per IS 456 :2000 for a group= 4 samples mean fck+3 and individual fck-3 3 samples mean fck+4 individual fck-2 1 sample fck+4 minimum But what about 2 samples is there any individual
Nice explain sir .... but I want to know that .as for example no of samples 1 Grade of concrete M-40 & test results is (37.8+47.1+47.1)=Average 44 Mpa. so sir that result is accepted or not please reply
I do provide quality - related knowledge for the activities happening on their site throughout the project. This is a one-time fee of ₹500/- which covers my services for the entire duration of the project. Let me know if You are interested.😊
Madat toh karega.. but such device is not readily available in India. Instead of acoustic detector, Thermal detector device is available in Gujarat and MUMBAI
I do provide quality - related knowledge for the activities happening on their site throughout the project. This is a one-time fee of ₹500/- which covers my services for the entire duration of the project. Let me know if You are interested.😊
Maine Cube acceptance criteria k bhut Sara video dekha h wo v details me but Really jo aj ap ne itne short time me itna bada doubt clear Kiya hai I just want to really thanks boss🙏 Great information
Please don't use Chlorpyriphos. Its cost per solution is high and effectiveness is low. It have higher vertical displacement and can contaminate ground water. So please use imidaclorprid 30.5%SE. THAT ALSO FROM REPUTED BRANDS LIKE BAYER. Price per litre will be high, but dosage will be much lower. You do the calculation and see. I have completely shifted to Bayer Primise. It's saving a lot of money and complaints
Could you please let me know where I can find carbon fiber polymer wrapping material? If you have any contacts, I would greatly appreciate your help, sir.
No. Repair should always be done by non-shrink grout. Because after repair work.. the originality, integrity and homogeneity of the structure is lost.. which may again cause structural failure Because lot of minor voids remain unfilled by regular mortar.. hence, by using non-shrink grout, we are ensured that there are no voids left behind. Also the repair work should always be done using a higher grade material..
Wo bich me 10 second ka jo clip tha.. wo toh Maine youtube se liya hai.. wo bleeding hai.. qki aggregates settle hojaate hain.. But jo Bubbles hain.. wo defoamer k wajah se