Flint & Walling, a family-owned manufacturer of premium pumps, motors and controls. Built on proven, comprehensive testing and generations of deep personal relationships with loyal customers and employees. A legacy of high-quality products where trust flows through everything we do.
For more information, visit www.flintandwalling.com
23;00 mark he mentions grounded leads but does not say if that is bad or good, he just says if you have resistance between leads then you are grounded- question I have 50 hp phase 480 volt motor, I disconnected the incoming power and used a fluce 2k ohm meter, one lead touching green and the other lead touching red, then green to black , then green to yellow- each reading i had resistance, just as if i was touching the 2 meter leads to one another- is this good or bad? thanks all.....
Awesome and very informative video! This video save me a lot of money and time when I found out it was my capacitor. Replaced it for $12 and all was good.
Check out what our partners have a chance to win! www.solostove.com/en-us/p/pi-pizza-oven?g_acctid=918-383-8176&g_adgroupid=&g_adid=&g_adtype=none&g_campaign=CTC+-+United+States+-+Performance+Max+-++Shopping+Only+-++Pizza+Ovens&g_campaignid=20625355916&g_keyword=&g_keywordid=&g_network=x&gad_source=1&gclid=CjwKCAjw8diwBhAbEiwA7i_sJTSPYCIUqGAEUGAlFYi0vC1QiLyXvSfrK7yNkiqUQJmBzMOP4ocTaRoCApwQAvD_BwE
My Wayne 1/2 HP water pump used to work properly, since half year ago, it suddenly to work irregularly. Sometimes it pump for 5 seconds and rest a while, sometimes 10 seconds and rest a while, sometimes 2-3 minutes, and and the rest period can be seconds to minutes, all irregularity. What exactly was going on?
I own one of your windmills from 1892. It's a Star Mill complete with the building that covers the structure. Three floor and 45 ft in height. One of the last ones still standing. It's located in Lake City, Pa.
Followed from DigDrive. GREAT Team work y'all. PS- Looks like you already have a pump choice critic...(I think he might be a little salty from criticism about the Franklin inline 400 he used in one of his videos.) Welcome to RU-vid! 😂 👍
My motor Y-B is 3.8 instead of 3.7 ohms Y-R is within range.. My 3W motor turns freely by hand but with power turns very slow and gets warm. How can I tell if it is the motor or motor controller.?
i have a house that is missing a neutral on the pole transformer. this transformer services 5 customers. my customer needs a well pump to work and with the new ground fault protection it knows there is no neutral from the grid hooked to the transformer. the transformer is hook on the secondary side to ground via 8 gauge wire and G/rod at the bottom of the pole. would be nice to see some info on this issue.
Wow...Wow! Oh my my..🤓👏🏽👏🏽🙏🏽. May I say that was the best, most awesome easy to understand “webinar” I’ve ever had. Why? Because as a layman and new to irrigation systems, I’m now ready to confidently calculate the numbers and go ahead and irrigate my two acre farm using rain harvested storm waters, stored in a man made shallow dam. Thank you Sir and KEEP IT UP. Regards, Jesse