If I remember correctly, you have to right click on the graph in the block diagram and then you have to uncheck on the option which say clear after each run
Thanks for the nice explanation please make a video on connector panes and how resource name is commonly transferring if we have so many Vi's using the same instrument
Hi, I followed the same procedure, but code isn't working, could you help me out? Mine is serial port and it is not reading decimal values. It says timeout expired before operation completed. And it is not reading number, it is reading alphabetical order.
Leak rate is calculated as mbarl/sec (mbar litre per seconed). This means rise in pressure in 1 litre of vessel in 1 seconed. The instrument which I am using, calculates the leak rate internally.
You can make the same programme as mentioned in the video, you can just use the command ':SOUR:VOLT 20' , it will sorce 20V. Please have a look at the manual download.tek.com/manual/2450-901-01_D_May_2015_Ref.pdf
is this working by field ionization or collision ionization. What i have read so far seems to indicate collision ionization but you described with field ionization. Also for collision ionization the magnetic field makes more sense to increase path length and ionization probability.
Hi Thanks for the nice comment, Actually field ionization helps in the ignition of the plasma and after that all the work by done high energetic electrons collision, You are right that these ions are affected by the magnetic field to increase the path length to increase the ionization
Yes you can. It is normally 0-10V DC and you can change the voltage from the front panel of SRS by selecting the aux out and then by rotating the knob.
@@BholuUPPbthanks for reply mam, i am research scholar and working on topological based materials.we have prepared some topological related samples but unfortunately we haven't measure resistivity data yet, if your institution or department have PPMS then please help mam, We tried some institutions but there are some problems with instruments. Please reply . Thank you
@@BholuUPPb so we are trying to measure the difference of two LED signal by using same two photodiodes. the output of the photodiodes are A and B in LIA. we have two issues, the reading of the LIA is drifting with time, and I keep see that the value of X is more than R
Not in this case, normally the method which is I am describing here is used for low resistance samples. What you are looking for is applicable for high resistance samples. In any case, you might want to take the inverse of the dV/dI in case of resistance samples.
Compressed gas is dried through Alumina beads and Nitrogen purification is done through by commercial filter (They do not disclose the chemical filter name)