Working of Penning gauge (practical)
3:11
4 года назад
Ferromagnetic Resonance (FMR)
4:53
4 года назад
Shubnikov-de Haas Oscillations
3:30
4 года назад
Hall effect
7:02
4 года назад
Air Housing unit (AHU) inside out
2:39
4 года назад
Spin hall effect
2:24
4 года назад
What is a sheet Resistance
3:53
4 года назад
Fundamental of leak detection
19:17
5 лет назад
Leidenfrost effect
3:29
5 лет назад
Комментарии
@krico28
@krico28 2 месяца назад
Thank you, you helped me a lot !
@vinayakshrote6340
@vinayakshrote6340 2 месяца назад
Very insightful and useful lecture! Thanks!
@joeyyeh8619
@joeyyeh8619 4 месяца назад
thanks
@TrantorTechInsights
@TrantorTechInsights 6 месяцев назад
Thank you!!
@sudhasmitaa
@sudhasmitaa 6 месяцев назад
can u share ur mob no i am having similar equipment i want to discuss.
@KaptainLuis
@KaptainLuis 9 месяцев назад
Thabk you!
@AnandKumar-kk6ue
@AnandKumar-kk6ue 11 месяцев назад
Person do have knowledge but unable to discribe properly,confusion lack of knowledge
@AnandKumar-kk6ue
@AnandKumar-kk6ue 11 месяцев назад
Great
@karthikeyanm9315
@karthikeyanm9315 Год назад
How did u learn about labview??
@BholuUPPb
@BholuUPPb 11 месяцев назад
By Myself
@mohmad3490
@mohmad3490 Год назад
This is informative. Thanku
@bhargavrajyaguru6887
@bhargavrajyaguru6887 Год назад
Good work. I need some help regarding these RF cables!
@xiao5212
@xiao5212 Год назад
Does your magnetic field is along the c-axis or can be in-plane? would you comment what would happen for the in-plane magnetic field? Thanks
@BholuUPPb
@BholuUPPb 11 месяцев назад
Here my magnetic field is out of plane of paper, I have to think what ahppens when the magnetic field is in the plane of paper
@vibhatkumar1583
@vibhatkumar1583 Год назад
My graph only shows points. And also it does not show old points. Like everytime a new reading comes, the previous point disappears. How to resolve?
@BholuUPPb
@BholuUPPb 11 месяцев назад
If I remember correctly, you have to right click on the graph in the block diagram and then you have to uncheck on the option which say clear after each run
@ldvelarde
@ldvelarde Год назад
Really helpful! The Edward's manual is super basic, thanks!!!
@BholuUPPb
@BholuUPPb 11 месяцев назад
Glad it was helpful!
@cryfier
@cryfier Год назад
thanks
@abhinavtiwari395
@abhinavtiwari395 Год назад
And what is one probe method
@BholuUPPb
@BholuUPPb 11 месяцев назад
You need to defined ground somewhere so I do not know what is meant by one probe, or I do not know enough
@Nyehehe995
@Nyehehe995 Год назад
So useful, thankyou!
@Electronics-ch9d
@Electronics-ch9d Год назад
Thanks for the nice explanation please make a video on connector panes and how resource name is commonly transferring if we have so many Vi's using the same instrument
@michalhaubner2104
@michalhaubner2104 Год назад
Hi, can you estimate how effective is the sintered filter in keeping he gauge clean, i.e. extending its lifespan under dirty vacuum?
@mamabear7351
@mamabear7351 Год назад
Hello I like your video where can I buy them ?
@dodomachine
@dodomachine Год назад
I sale HLD,How I contact you?
@jasneetpala1996
@jasneetpala1996 Год назад
Hi, I followed the same procedure, but code isn't working, could you help me out? Mine is serial port and it is not reading decimal values. It says timeout expired before operation completed. And it is not reading number, it is reading alphabetical order.
@BholuUPPb
@BholuUPPb Год назад
Could you send me the screenshot
@patelindravadan9978
@patelindravadan9978 Год назад
Sir please please tell about how to calculate leakage rate
@BholuUPPb
@BholuUPPb Год назад
Leak rate is calculated as mbarl/sec (mbar litre per seconed). This means rise in pressure in 1 litre of vessel in 1 seconed. The instrument which I am using, calculates the leak rate internally.
@sindhujavarma5053
@sindhujavarma5053 Год назад
Please make a labview instrument control foe keithley 2450
@BholuUPPb
@BholuUPPb Год назад
You can make the same programme as mentioned in the video, you can just use the command ':SOUR:VOLT 20' , it will sorce 20V. Please have a look at the manual download.tek.com/manual/2450-901-01_D_May_2015_Ref.pdf
@md.zafaralam
@md.zafaralam Год назад
thanku well explained ...... if possible please explain valleytronics too...
@shahidvlogs4151
@shahidvlogs4151 Год назад
What is the grade of helium gas?
@BholuUPPb
@BholuUPPb Год назад
99.9995 (5N)
@anilloura9498
@anilloura9498 Год назад
In which lab you're working 😍
@BholuUPPb
@BholuUPPb Год назад
Now I do not work in India
@anilloura9498
@anilloura9498 Год назад
@@BholuUPPb where are you nowadays?
@michaelmo267
@michaelmo267 Год назад
Awesome vid, one question though.. how much would a set up like this cost?
@sarakimmig7495
@sarakimmig7495 2 года назад
Excellent.
@Urr_66
@Urr_66 2 года назад
Thank you Sir
@BholuUPPb
@BholuUPPb Год назад
Most welcome
@Cosmos-2022
@Cosmos-2022 2 года назад
Nice tutorial, Please do more Labview instrument control, such as I-V charateristic from DMM with separation power source.
@BholuUPPb
@BholuUPPb Год назад
I will try!
@maheshthummala9938
@maheshthummala9938 2 года назад
Thanks a lot👍
@BholuUPPb
@BholuUPPb Год назад
You are welcome
@jimpanse1638
@jimpanse1638 2 года назад
is this working by field ionization or collision ionization. What i have read so far seems to indicate collision ionization but you described with field ionization. Also for collision ionization the magnetic field makes more sense to increase path length and ionization probability.
@BholuUPPb
@BholuUPPb 2 года назад
Hi Thanks for the nice comment, Actually field ionization helps in the ignition of the plasma and after that all the work by done high energetic electrons collision, You are right that these ions are affected by the magnetic field to increase the path length to increase the ionization
@onurercem4448
@onurercem4448 2 года назад
ı realy grateful for this great explanation. ı got error -1073807339 at visa read. can you help how ı can fix it
@sonikesarwani1770
@sonikesarwani1770 2 года назад
Sir please share you email id so that I can discuss
@sutanudas8967
@sutanudas8967 2 года назад
Can I get DC voltage using Aux output from lock in? If I can please help me sir!
@BholuUPPb
@BholuUPPb 2 года назад
Yes you can. It is normally 0-10V DC and you can change the voltage from the front panel of SRS by selecting the aux out and then by rotating the knob.
@kuntalsingh6609
@kuntalsingh6609 2 года назад
thank you
@BholuUPPb
@BholuUPPb Год назад
You're welcome
@PradhanS03
@PradhanS03 2 года назад
Can you please explain Berry phase.?
@BholuUPPb
@BholuUPPb Год назад
I will be making a video soon.
@PradhanS03
@PradhanS03 Год назад
@@BholuUPPbthanks for reply mam, i am research scholar and working on topological based materials.we have prepared some topological related samples but unfortunately we haven't measure resistivity data yet, if your institution or department have PPMS then please help mam, We tried some institutions but there are some problems with instruments. Please reply . Thank you
@BholuUPPb
@BholuUPPb Год назад
@@PradhanS03 Sorry man, I have completed my PhD and right now I do not have an affiliation to any institute in India.
@PradhanS03
@PradhanS03 Год назад
@@BholuUPPb Ok thank you
@huongnguyen-lc1pe
@huongnguyen-lc1pe 2 года назад
how did you do it can you share with me , thank you
@BholuUPPb
@BholuUPPb Год назад
Which part?
@malekmastafa1501
@malekmastafa1501 2 года назад
The value of X ois greater than R!!
@BholuUPPb
@BholuUPPb 2 года назад
Could you please point out the time at which you saw the value of X is greater than R
@malekmastafa1501
@malekmastafa1501 2 года назад
@@BholuUPPb so we are trying to measure the difference of two LED signal by using same two photodiodes. the output of the photodiodes are A and B in LIA. we have two issues, the reading of the LIA is drifting with time, and I keep see that the value of X is more than R
@malekmastafa1501
@malekmastafa1501 2 года назад
the measurement is A-B
@elwafi2001
@elwafi2001 2 года назад
Very good job 👏
@BholuUPPb
@BholuUPPb Год назад
Thank you! Cheers!
@9916516557
@9916516557 2 года назад
Can you provide your email/phone need to discuss my lab view problem
@vivekshinde2177
@vivekshinde2177 2 года назад
Does it make vaccum it self?
@BholuUPPb
@BholuUPPb 2 года назад
Yes, It has roughning as well as a turbo pump.
@BholuUPPb
@BholuUPPb Год назад
Yes, It has both roughening and turbopump
@PradhanS03
@PradhanS03 2 года назад
Hi, how to symmetrization in origin. Please help me
@ericchandler2328
@ericchandler2328 3 месяца назад
(0 - 0)/2 = 0 (0 + 0)/2 = 0
@nachiketakumar9645
@nachiketakumar9645 3 года назад
Wow nice explained, please make a video on quantum processors 🙏
@BholuUPPb
@BholuUPPb Год назад
Will do soon
@sangram2fao
@sangram2fao 3 года назад
So good to hear your voice after so long. Hope you are doing well. :)
@sahib1269
@sahib1269 3 года назад
I am trying to fix the issue of OVLD red light. Do you have any idea how to fix it?
@BholuUPPb
@BholuUPPb 3 года назад
you have to tell me what are you trying to measure.
@roopkumar8968
@roopkumar8968 3 года назад
Is measuring DV DI is same as measuring DI DV ? And is their any way to convert DV DI to DI DV ?
@BholuUPPb
@BholuUPPb 3 года назад
Not in this case, normally the method which is I am describing here is used for low resistance samples. What you are looking for is applicable for high resistance samples. In any case, you might want to take the inverse of the dV/dI in case of resistance samples.
@roopkumar8968
@roopkumar8968 3 года назад
@@BholuUPPbmy sample is also low resistance. I am measuring db di. My question is can I inverse dv di to calculate di dv ?
@BholuUPPb
@BholuUPPb 3 года назад
@@roopkumar8968 yes
@leeanncapistran3582
@leeanncapistran3582 3 года назад
Would it be possible to do this for a NI PX-1033?
@BholuUPPb
@BholuUPPb 3 года назад
Although I have not used NI PX-1033, if it has a GPIB port, ethernet port or USB port then it should be possible.
@user-nk9yw7jj8p
@user-nk9yw7jj8p 3 года назад
thanks from south korea
@BholuUPPb
@BholuUPPb Год назад
You are welcome
@YuvrajSinghRathourA
@YuvrajSinghRathourA 3 года назад
Filter name please
@BholuUPPb
@BholuUPPb 3 года назад
Compressed gas is dried through Alumina beads and Nitrogen purification is done through by commercial filter (They do not disclose the chemical filter name)