Тёмный

कितने Sq mm की तार कितना करंट ले सकती है । Copper Wire Size Selection Based on Current Capacity 

Civil Engineering Forum
Подписаться 64 тыс.
Просмотров 191 тыс.
50% 1

कितने Sq mm की तार कितना करंट ले सकती है । Copper Wire Size Selection Based on Current Capacity
In this video, I have explained the wire size selection procedure.
This video is about various wire sizes used at home for different appliances like TV, fridge lighting circuits, fan ,cooler etc. Here we discuss about different sizes of Wires available in market 1,1.5,2.5,4, and 6 sq.mm and current carrying capacities of wires and also their uses at home.
#wiresize #Wire #wiring #electric #housewiring #wiringconnection #testing #test #Panelwiring #electricalsupplies
link to my RU-vid channel
CIVIL ENGINEERING FORUM : / civilengineeringforum
Email Address: pratik.933@gmail.com
Contact: 9016464933

Хобби

Опубликовано:

 

14 дек 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 61   
@sajanjosemathews7413
@sajanjosemathews7413 Год назад
Very useful video dear brother. Very nice description. Keep it up .Thank you .
@CivilEngineeringForum
@CivilEngineeringForum Год назад
Thanks for watching 🙏🏻
@rajeshthakur8222
@rajeshthakur8222 3 месяца назад
😊😊​@@CivilEngineeringForum
@amitkumarsinha9463
@amitkumarsinha9463 Год назад
Aam aadmi ke 3 bhk ke ghar me jaha 1 ac ya ek geyser, Iron, mixer grinder, room heater or Pani ka ek moter chalta hai waha Maine board se room ke boards me maximum 4 mm wire sufficient hota hai....AC or geyser dono ek saath to chalna nahi hai ....room heater bhi winter me hi chalega...1 mm for fan, tv, bulbs ke liye sahi hai jo room ke boards switch se point ko jayega.... Service wire ke liye 10mm ka aluminium wire use kare wo copper se sasta parega....
@mitabenpatel5611
@mitabenpatel5611 Год назад
Nice, thank you
@OnlyElectricalEngineering
@OnlyElectricalEngineering Год назад
Nice and knowledgeable🎉
@muralidharanr5001
@muralidharanr5001 10 месяцев назад
Thanks
@Ombtechwalla
@Ombtechwalla 6 месяцев назад
Very nice video
@skgarg272
@skgarg272 5 месяцев назад
Very very useful. Skg
@irfanmakrani4117
@irfanmakrani4117 Год назад
Ha sir mare gharpe vayaring to nhi hay abhi par muje taatkal main vayar karna ahy to garpe to main apse pucha na cahta tha ke 1.00mm ka anchor ka varar us kar sakata ho muje 9 volteg ke balaf aur aur fen 3 hay to aur ek pani ki motar hay adhe ki to sir uas kar sakte hay batana to sahi rehmga sir kiya thenkue
@arunavapramanik4998
@arunavapramanik4998 9 месяцев назад
1 SQ MM WIRE 10 AMP LOAD LETA HAI
@rajendrabhandari448
@rajendrabhandari448 10 месяцев назад
Nice
@JaspalSingh-xu5ou
@JaspalSingh-xu5ou 6 месяцев назад
Be careful, some companies put misleading labels, when they mark 4 mm square, it may be far less.
@ramkrishnabagdi6274
@ramkrishnabagdi6274 10 месяцев назад
.75mm lap/fan. 1mm iron 1hp pump motor. 2.5 ac. 4mm Main swtich .
@SatishKumar-vu9ru
@SatishKumar-vu9ru 7 месяцев назад
Thank you Sir for the valuable information
@CivilEngineeringForum
@CivilEngineeringForum 7 месяцев назад
🙏🏻
@V98000
@V98000 14 дней назад
Always use 10mm both wire from main meter to distribution box, after that you can use different guage wires
@AshuSharma-lm6qf
@AshuSharma-lm6qf 5 месяцев назад
Hello paji ma punjab sa electrision jasa koi valding sat wali machine ha vo chalti ha double phase jab ham uski single wire par amp batati ha 25 amp ab ma es bat ka pata nahi chal raha ki 25 amp ki ha ya 50 amp ki jas koi ac hota vo late 7 sa 8 amp par vo chlta single phase par us pr lagate ha 2.50 mm ki wire ab ya janna chahata hi jo double pase wai machine ha jo 25 amp ki us par kitne mm ki wire lagau
@pragyanargesh2121
@pragyanargesh2121 9 месяцев назад
Sir Induction me 10 Ampere current lgta h to fir hme konsa cable use Krna chahiye because me kbhi kbhi use krti hu
@sourishghosh4628
@sourishghosh4628 Год назад
bhai mere circuit me 24v 1amp rating hai konsa wire lu ? 1mmsq ki 1.5mmsq
@freemusicncm1785
@freemusicncm1785 6 месяцев назад
Aaj kaal 2.5 mm mein AC, Geyser ka kaam ho jaata hai, iron, fridge & heater k liye 1.5 mm, baaki 1mm
@imtiyazrisaldar3211
@imtiyazrisaldar3211 Год назад
Sir thank you very much,,, sir thank you very much,,, please put about more about electrical thank you very much I am from bangalore city,,, I will give you 5 stars
@CivilEngineeringForum
@CivilEngineeringForum Год назад
🙏🏻 Welcome and than you for watching
@Rock-xw1ty
@Rock-xw1ty 8 месяцев назад
Electric pole se meter tak ka kitne ka wire use krna chahiye
@hemsinghmaurya8286
@hemsinghmaurya8286 6 месяцев назад
Dc. Grinder me kitna mm ka wire chayiye copper ka
@bebduehxbd
@bebduehxbd 23 дня назад
22 amprer 3 ac ka load hai 4 mm wire pr chalega kya ??
@kurbanali616
@kurbanali616 Месяц назад
Ok sir
@ashfaq_kazi
@ashfaq_kazi 10 месяцев назад
Multiply by 5 ka formula Kahan se laye? Mere paas geyser hai 3000 w ka uske sath Bajaj company ne 1.5 sqmm ka wire dhiya hai aur woh 6 saal se chal Raha hai . Voltas ka 1.2 ton 1200 w ka ac hai uske saath bhi 1.5 sqmm ka hi wire hai woh bhi 5 saal se chal Raha hai. 4 sqmm par poora Ghar ka load aasani se chalta hai. Tube, fan ex. Fan k liye toh 0.5 sqmm hi kafi hota hai ya zayada se zayada 0.75 sqmm. Mota Mota hisab yeh hai k agar best quality ka copper wire hai toh 1 sqmm 10 A tak load le sakta hai.
@sauravkumarbhardwaj9297
@sauravkumarbhardwaj9297 Год назад
Sir 6mmwire 5meter kitne ka hai
@user-gg7zv4lr4r
@user-gg7zv4lr4r 6 дней назад
❤❤❤❤❤❤❤❤❤
@MoHaN-my8mc
@MoHaN-my8mc 7 месяцев назад
Why multiple 5 ?
@rajputavi
@rajputavi 28 дней назад
Kya hm pure Ghar me 2.5mm ke wire se waring kr sakte hai
@tabittatin5182
@tabittatin5182 7 месяцев назад
Sir 5 se multiply matlap nhi samja?
@Meresafarkimanjil
@Meresafarkimanjil 7 месяцев назад
Sir ye 5 se multiply aapne kese Kiya ye samajh mai ni aaya, digit 5 hi kyu li aapne multiply ke liye, aur digit kyu ni li,koi formula hai kya iska sir,ye please bata dijiye
@CivilEngineeringForum
@CivilEngineeringForum 7 месяцев назад
its thumbrule
@ajiteshpaul8931
@ajiteshpaul8931 Год назад
Sir mera meter load 3.5kw hai and 6mm service wire hai kya mein 2 split ac 1.5 ton wala ek saath use karu??
@amitkrstyle
@amitkrstyle Год назад
It will trip, load 5 kw karo, and limit other appliances.
@BiriyaniKHABE
@BiriyaniKHABE 4 месяца назад
Ac ke liye 2.5 sq mm enough hai
@shankarvaigankar8116
@shankarvaigankar8116 Год назад
What will be current carrying capacity of two 4 sqmm wire. It will be equalant to 8sqmm wire. Which one will burn first due to over current. Single wire of 8sqmm Or 2 x 4sqmm wire = 8sqmm.
@RohitChaudhary-jw2mw
@RohitChaudhary-jw2mw 9 месяцев назад
3hp single phase water pump k liye kitne mm ka wire achha hoga?
@RaviKumar-uy8ss
@RaviKumar-uy8ss 7 месяцев назад
agar jyada dur nhi to 2.5 mm otherwise 4.mm
@prashanthc8135
@prashanthc8135 10 месяцев назад
Is this applicable for copper wire or aluminium wire
@hypertheorytech2578
@hypertheorytech2578 6 месяцев назад
Service wire aluminium ka use hota hai. Copper ka conductivity jyada hota hai aluminium se.
@asifgull9650
@asifgull9650 Год назад
Which wire is sufficient for OVEN ?
@sanjeevlima6642
@sanjeevlima6642 Год назад
2.5 mm wire
@MubisharsirajMubisharkha-qu9jp
@MubisharsirajMubisharkha-qu9jp Месяц назад
Mubishar siraj khan electriction
@priyanchala5466
@priyanchala5466 Год назад
Inverter ke liye kitne mm ka wire use kren......
@technicalraja-ld2mp
@technicalraja-ld2mp Год назад
1.5
@asianbuilder3344
@asianbuilder3344 Год назад
It's not multiplying by 5 but by 6 like 1x6= 6Amp for 1 sqmm wire as per IS codes
@surajitgayen87
@surajitgayen87 10 месяцев назад
yes absolutely correct, but it too depends on company, some offers upto 8-9 amps, but to be on safe side we take 6 amp
@biharibabualive
@biharibabualive 3 месяца назад
Mai 3 saal se 1 mm wire 16 amp pe use kar raha hu 😂😂😂😂
@Music-dn9uy
@Music-dn9uy Месяц назад
😂😂
@AmitKumar-tf8jf
@AmitKumar-tf8jf Год назад
Sir 10 mm wire hm direct ghar ka connection pole se kar sakte hai???
@dipak-nc2mc
@dipak-nc2mc Год назад
Ha bhai
@Rock-xw1ty
@Rock-xw1ty 8 месяцев назад
Pole se ghar ka connection 6mm wire se kr skte h kya
@GayatriSonune-bg9qf
@GayatriSonune-bg9qf 7 месяцев назад
​@@Rock-xw1ty bhai ispe 6kv load 24hr chal sakta hai kya
@knowledgepower3123
@knowledgepower3123 Год назад
4 mm wair har saman use kar sakte h. Bewakoof
@sauravkumarbhardwaj9297
@sauravkumarbhardwaj9297 Год назад
Thanks
@user-gg7zv4lr4r
@user-gg7zv4lr4r 10 дней назад
❤❤❤❤❤❤❤❤
@GMZEntertainment
@GMZEntertainment 11 месяцев назад
Thanks
@CivilEngineeringForum
@CivilEngineeringForum 11 месяцев назад
🙏🏻
Далее
Разоблачение ушные свечи
00:28
Просмотров 291 тыс.
делали такой маникюр??😁
1:00
Просмотров 4,5 млн
You have to stir it good 👌 (ib: tt/michael_bias)
0:21