Bhut achi video ha ap ki sir ma apna window ac khud bnaa raha hu mana evaporator pona ton alag liya condenser alag liya aur body ma laga diye phir mana compressor lagaya compressor checked ha us ma back wagera nai self vacume kar ka gas bhari r22 tou 70psi pa la kar chordiya suru ki thori si nalian thandi ho rahi han lekin baqi evaporator pa thandak nai a rahi ha jis ki waja sa cooling nai ho rahi mana 0.055 ki capillary use ki ha 32inch length ma double capillary ha
Bhai aap kahan se ho Ham aapko apna Aisi dikhana Chahte Mera AC 20 Sal Purana Hai ismein cooling problem hai 1.5 tan ki carrier AC hai please aap mujhe bataen
Mere Pas 1ton ka Ac Hai window Lkin Gass Recharge Karne sy Phele Bhoot Teez Cooling karta tha Kharab Hone k Bad Ab Cooling Teez nai karta Kya Waja Ho Sakhti Hai Sir please Reply karna
Bhai hamari general window ac chalte chalte gas leak Kara michanic nai gas leakage band Kara or Thora gas Dala abhi pehle wali cooling nhi hai Kya gas qam hai or gas k gage Kitna hona chahiye
Bai mere paas lg window ac hai 1.5 ton or uski compressor ki rubber khatam hai or jabh compressor cut hota hai to bhut awaj karta hai keya rubber change karne se yeh dikat khatam ho jayegi???
Bhai mera Hitachi ka inverter ac hai jab fan speed auto pe hoti hai cooling mode mein toh ac thodi der badh compressor band ho jata hai.Jab fan speed manually set karte hain to thik chalta hai.Kya problem ho sakti hai?
Bhai mere pas onida inverter ac hai kuchh din pehle tak mera ac sirf 4 units hi leta tha 1 din chalane me around 12 hours mai chalata tha ac ko vo bhi 31 degrees par ab kuchh dino se mera ac around 20 units per day consume karna start ho gya hai . Conpressor bhi most of the time chalta rehta hai full speed pe vse to puri thandi hawa deta hai pls bataiye kya problem ho skti h jo power consumption 5 times badh gyi hai jabki bahar ka temperature bhi sirf 34 -35 degree hi h. Kamra bhi mera pura sealed hai or na hi koi heat source hai kamre me
Bai g. Ik window ac aa... Cooling coil te ice aa rhi c.. Capillary change krti gas nwi paati... Hun v cooling proper ni hai blower speed thk hai service v kita hoya compressor v thk hai... Please dso ki kriye
Mera windo ac h voltas 1.5 ton ka problam ye h ki jese jyada garmi hone per torbo mode per ac chalta h to campersar jyedi der Tak on nhi ratha fo ho jayta h jitni coling keri thori der bad garmi ho jyti h aysa kyo ho rha h batay
Split ac h 1.5 ton ka bluestar ka uski coil change kri h Phle usme almunium ki coil thi Ab copper ki dlwai h Cooling phle jaisi nhi kr rha 15 degree ki hwa de rha h Ac mechanic kh rha h hmari trf se ok h. Lekin ac km cooling kr rha h To kya uski capilary kharab h
भाई एक बात बताए ये जो आपकी टोर्च है और सिलेंडर है ये आपने कितने का लिया था और इस रिफिल कैसे करते हो मतलब खुद करते हो या मार्किट से कराते है और एक रिफिल में ये कितने टांके लगा देता है पता नहीजब मार्किट मे हमने ये देखा तो हमे इसको लेने की सलाह किसी ने नही दी और बोला कि बूटेन के जो सिलेंडर आते वो लो कोई उनको रिफिल करने मि भी जरूरत नही खरीदो ओर काम करो और इस सिलेंडर की फ्लेम है वो भी ठीक नही निकलती ऐसा भी बताया था अगर इसके बारे में आप बता सके
Bhai ji mera ek window ac h 1 ton ka bo 15 min 20 min chalne ke bad apne ap se hi compressor trip ho jata hai bas fan ghumta rehta hai fir 2 min bad compressor start ho jata hai circuit board nahi h direct h yrr kia problem hai bhai ji koi idea !!
Mera AC cooling nhi kr rha tha aur jb usko dikhaya to minor likage ki problem btaya usko shi kiya lekin fir bhi vo cooling nhi kr rha hai ache se kya problem ho skta hai??
Hamara ac Gernal company ka hai window ac har 30 sacond me kat mar deta hai room me coling nahi ho rahi hai capester cheek kiya wo bi sahi hai to bhaiya isme kya problam hai
Bhaiya ek question tha ki agar window ac sirf fan mode Mai chale tho kyaa vo ceiling fan jitna bill uthega Mera bluestar 5⭐ ac hai please reply for 1 month
Paa ji mera room 12 by. 12. Ka he. 1.5 ton ka voltas ka ac he. Mene use bathroom ke andar lagaya he. 20 mnt chalne ke bad. Trip marke comrassar band ho jata he fir fir 40 mnt bad chalta he bathroom me kafi garmi bhi ho jati bas get khula rehta he bathroom ka kya heet jyada hone ki vaja se trip hota he. Jabki dusre room ki khidki me tha par room ke andar hi tha tab thik chalta tha. Kya dikkat ho sakti he marg darshan kijiye
Sahi kaha aapne. Bathroom se hata ke khidki me laga liya achha chal ra he par kal raat se. Awaaj kar ra he gharrrr gharrrr ki jab compressor on hota tab awaaj karta he lekin jab compressor band karta hu tab. Awaaj bilkul nahi karta. Aaj kholke check bhi kiya par folt Samjh nahi aya. Cepecitor bhi ok he
Carrier windows ac me sound bahut arha tha hum ne uske undar ke pipe ko rasi me bandh diya uske baad hi cooling adha hogaya h... Abhi rashi khol diya h uuske bavjood cooling nh karti h...plz reply
Room(10x12) mein cooling nahi hoti jabki abhi gas fill karai hai , 4-5 hrs compressor chalta rehta hai aur 25°bhi nahi pahuchti cooling room mein kya karein . Koi miisture nahi hai coils par lenin ac wale ka temperature unit 16° show karta hai
Same problem. Dakin inverter ac 1.5 ton 5yr old When running Back pressure 135. Current 6.2 amps. Indoor coil mein moisture naheen hain. Indoor blower mein thermometer daala hain. temp 16'c aa rahan hain. Mera new 2nd ac 6'c dikhata hain. Indoor blower main. Any help appreciated
@@gagandeeo8720 Its Fixed now I think. Problem was with Outdoor pcb. It did not run the Compressor to Full Capacity. Current was 4-5 amps max. 6.3amps for a little bit. Fix - Changed the pcb, Filter + Capillary, then vacuumed+gas again, Gas Runnig Pressure 150psi. now current ranges from 4-5 amps, then 6.3 amps then 8 amps. It does cool. Current goes to 8 amps but the rated Max current 6.4 amps. so I dont know If its the correct Fix. but will use it for some time to see how things go.
Aadhe Koyal Thande ho rahe hain upar wale Qawwal niche Wale Ko Aaegi Thandi Nahin ho rahe iska kya solution hai pahle 36 number capital name Lagi Hui Hai