🤯How much HEIGHT can a MAXIMUM water PUMP SUCK? 

Ruben Cobos
Подписаться 63 тыс.
Просмотров 49 тыс.
50% 1

What is the maximum height at which a peripheral pump with negative suction can suck water?
Why is it impossible for the pump to lift more than 10 meters in negative suction?
How does the pump generate a vacuum in the suction?
What is the value of atmospheric pressure at sea level?
How does atmospheric pressure affect the suction capacity of the pump?
Why is it difficult for a pump to achieve absolute vacuum?
What is the percentage of total vacuum that a pump can achieve under ideal conditions?
Why is it not always recommended that a pump suction up to its maximum head?
What instrument is used to measure vacuum at the pump suction?
What happens when the valve is throttled to increase suction?
What is the duty point of the pump at discharge?
How is greater suction simulated in the test?
What is observed on the vacuum gauge as the suction valve closes?
When does the cavitation phenomenon start?
What are the bubbles observed in the suction hose?
Why do vapor cavities occur in cavitation?
How does the sound of the pump change when cavitation occurs?
What is the suction limit of the pump in the test?
What is the main risk to which a pump is exposed when cavitation occurs?
What is the maximum suction capacity of the peripheral pump in the test?
Relevant keywords or phrases:
Maximum suction height
Peripheral pump
Negative suction
Atmospheric pressure
absolute vacuum
Percentage of total vacuum
work point
Suction valve
Vacuum gauge
Cavitation
Air bubbles
steam cavities
Sea level
Geographic altitude
Pressure gauge
pump discharge
Cavitation phenomenon
Working range
Measuring instrument
water circulation
Pump noise level
Vapor cavity implosion
Suction lift management
Cavitation damage in pumps
Hydraulic performance tests
Pump Suction Sizing
Vacuum tests on peripheral pumps
Risks of excessive suction
Water circulation in the hose
Characteristic sound of cavitation
Effects of altitude on hydraulic pumps
Complications at high geographic altitudes
Proper handling of the suction valve

Опубликовано:

 

29 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 85   
9 месяцев назад
Aprende a seleccionar las bombas de agua correctas para aplicaciones residenciales, te invito a mi curso online. haz click al enlace: rubenfcobos.com/seleccion-tec/
@luisrobertoromerorincon5447
@luisrobertoromerorincon5447 9 месяцев назад
Que buena explicación tengo una duda si voy a subir el agua a 20 metros de altura por ejemplo y la bomba me chupa a una altura de 1 metro y arriba me bota x caudal si aumento la profundidad de donde succiona por ejemplo a 4m el caudal que sale arriba disminuye?? Poco arto? Gracias por responder
9 месяцев назад
Efectivsmentr la altura de succión se suma a la carga total de la bomba, por ejemplo si la bomba entrega 120 lpm a 24 metros, estos 24 podrían ser 4 de succion y 20 de elevación. Saludos cordiales
@jhonamu9666
@jhonamu9666 Месяц назад
Buenas...estoy en u. Apartamenro en un quinto piso... de cuatro aparatmentos cada piso...y el agua llega hasta el tercer piso...alos apartamento pero tiene una tuberia principal de 3 pulgadas o mas ...si pomgo una bomba en mi piso me subcionara..?
@XEROXXNS
@XEROXXNS 3 месяца назад
Buenas noches ingeniero, sus videos muy teoricos y buenos, paso a hacerle una consulta, mis cisternas de agua estan a 2 metros bajo tierra( seria tuberia vertical) y a unos 4 metros en horizontal de la bomba de agua, Tengo una bomba de 2hp con una tuberia de succion de 1¨ y me esta generando cavitacion, vivo en costa, cree que sea por la reduccion de diametro? Pero me parece raro ya que pedrollo en su linea de bombas de 3hp usa 1 1/4 y entre 2hp y 3hp, la diferencia es mucha y la diferencia de diametros no mucha. Saludos
@jliners6035
@jliners6035 9 месяцев назад
Desde mi humilde opinion creo que tiene un error de conceptos, la altura maxima de succion lo determina el ampa o npsh requerido.saludos
9 месяцев назад
Estimado, lo que usted dice es correcto, este video es el principio de una serie de videos que concluye con el cálculo del NPSH, todavia no los he terminado, pero la intencion es llegar a ese punto. Revise lo que yo indico acerca de los 8 metros (en las mejores condiciones) gracias por su aporte.
@j.andressanaguaray2244
@j.andressanaguaray2244 2 месяца назад
@@jliners6035 osea eso quiere decir que puede succionar más de 8 metros ?
@rennyledezma1566
@rennyledezma1566 Месяц назад
Gracias por su aportación, tengo una bomba centrifuga de 15hp entrada de 2" a 3 mts de profundidad npsh 4.56 mts, mido -23psi en la succión y me provoca cavitacion
@cutbertoresendismoreno8912
@cutbertoresendismoreno8912 Месяц назад
Buenas tardes maestro yo acabo de comprar una bomba nueva porque pense que era la falla en las bomba pero no se el pozo que tengo ya se bajo a 8 metros y medio y ya no quiere subir el agua que se puede hacer
@joseluiscarmonajimenez5118
@joseluiscarmonajimenez5118 19 дней назад
@@cutbertoresendismoreno8912 una bomba de pozo profundo, de bala
@jeansilva9433
@jeansilva9433 5 месяцев назад
Maestro tengo una bomba de 1hp jalando agua de un aljibe que tiene 6 metros de profundidad y del aljibe a donde se encuentra la bomba hay 9 metros, me trabajaría bien con esas distancias? Agradezco su respuesta
@ernestoholguin1784
@ernestoholguin1784 4 месяца назад
Amigo, para que tú bomba sea eficiente y estés contento con los resultados necesitarías poner la bomba recién saliendo del aljibe esto para que sea Aprox 6.5 metros a 7 por la distancia que te tome la instalación, posterior a ello si la tubería saliendo del aljibe es horizontal te iría muy bien, sin embargo. Si los 9 metros que tienes distancia son en vertical ( tubo de subida) verías un poco mermado la elevación del líquido. En conclusión, instala la bomba recién salga del aljibe para que sea eficiente de otra manera no verás buenos resultados o en su defecto no abra succión. SALUDOS CORDIALES!!
@hugoarmandoyuing4728
@hugoarmandoyuing4728 5 месяцев назад
Hola buenos días, podría apoyarme, tengo un pozo de agua de 12 metros de profundidad, de agua talvez tendrá como dos metros, el diámetro del pozo es de 1.50 metros. Compré una bomba sumergible que decía, para 120 mtros de altura, de un caballo, tipo bala, pero resulta que no tiene potencia, tiene salida a uno 1,1/4 de pulgada, lo saqué así hasta la superficial, pero la presión es mínima,ya reduje desde la salida de la bomba a pulgada,ahí si aumento un poco la precion, mi problema es que el cable de la bomba se caliente, la bomba trajo 20 metros de cable de fabrica, sol para conectar. Que podrá ser na falla, del calentamiento y precion. La bomba funciona a 110 vol. La energía que tengo varía de 105 A 108 voltios. Gracias espero me responda
5 месяцев назад
Usted tiene falta de carga dinámica por eso la bomba se recalienta, en la superficie debe instalar una válvula de compuerta y cerrarla para estrangular un poco la salida. Con eso la bomba va a entrar en curva, generará carga dinámica y no sobrecalentara. Saludos. Suscribase.
@rigobertojimenezordonez4352
@rigobertojimenezordonez4352 5 месяцев назад
Ingeniero que bomba nesecito para succionar agua a 30 metros verticales....de un aljibe de agua...agrdeseriq que me ayude
5 месяцев назад
Solo sumergible, saludos.
@franciscorivera8134
@franciscorivera8134 Месяц назад
Buenas noches mi estimado muchas gracias por enseñar a manejo de una bomba muy amable que Dios le bendiga amiguito
@luiscarlossacristanbohorqu8493
@luiscarlossacristanbohorqu8493 5 месяцев назад
Señor Rubén Cobos,en este momento usted está siendo mi maestro,agradezco mucho por sus videos y su contenido ya que en este momento lo requiero en mi empleo,usted es una persona que tiene mucho conocimiento,de nuevo muchas gracias y le envío un fuerte abrazo desde mi país Colombia.
@carlosantunovich6724
@carlosantunovich6724 5 месяцев назад
Sería bueno que hagas un video explicando lo contrario, es decir COMO INSTALAR cañerias que llevan el agua en forma Horizontal, por ejemplo desde una represa o laguna hasta una plantación de frutales u otra cosa a distancias considerables, 300, 500 800 metros, saber como influye una pequeña pendiente negativa y que tipo de perdidas hay, en mi caso tengo una Bomba de 20HP entrada 2" 1/2 y salida de 1 1/2, tomamos agua de una represa, la bomba apenas está poco mas de 1 metro elevada sobre la superficie del agua , el caño hasta su destino final es de 1 1/2, segun las curvas de rendimiento la bomba deberia darnos 45.000 litros, pero luego de recorrer 500 metros con una elevacion de apenas 1.3 metros en ese recorrido apenas recibimos 10.000 litros
5 месяцев назад
Muchas gracias por la sugerencia. Ya había pensado hacer un video sobre succiones complejas, pero me has aportado otros aspectos. Me voy a poner a trabajar!
5 месяцев назад
Me gustaría que me envíes un video de esa instalación.
@carlosantunovich6724
@carlosantunovich6724 5 месяцев назад
@ Gracias a Usted, es un problema muy comun en las zonas de produccion agricola, tambien seria bueno obtener datos para colocacion de bombas en serie para ir llevando aun mas lejos el agua
@carlosantunovich6724
@carlosantunovich6724 5 месяцев назад
@ con mucho gusto.
5 месяцев назад
@@carlosantunovich6724 +593979435715 gracias
@serbioespinoza-gm3hm
@serbioespinoza-gm3hm 4 месяца назад
Que pasa si le pongo un tanque presion a la bomba.
@toryandrade7130
@toryandrade7130 6 месяцев назад
Exelente, ecplicacion, tengo una duda, que sucede si el pozo profundo es de 25 metros y coloco esta bomba en el interiorr del pozo, a 7 metros de la lamina de agua, lograria bombear?
6 месяцев назад
Si pero ya es más difícil.
@AngelRomero-vm5yg
@AngelRomero-vm5yg 6 месяцев назад
Eso es por que el agua hierve al bajar la presión. Puede llegar a sublimar. Un saludo 😇
@gusifuentes7358
@gusifuentes7358 2 месяца назад
Amigo a q distancia debe estar la motobomba del tanque? Los 8 metros son solo de profundidad o también influye la distancia q tenga delntanque?
@GilbertoCastano-zg5ug
@GilbertoCastano-zg5ug Месяц назад
Creo q también tiene q ver la potencia
Месяц назад
@@GilbertoCastano-zg5ug saludos, la.potencia de una bomba no incide en la altura de succión.
@GilbertoCastano-zg5ug
@GilbertoCastano-zg5ug 19 дней назад
Saludos en una succión negativa debería Aver unadiferencia entre una bomba de un caballo y una de 3o 4 hp la más grande deve arrastrar agua desde más abajo
@GilbertoCastano-zg5ug
@GilbertoCastano-zg5ug 19 дней назад
De más abajo
@GilbertoCastano-zg5ug
@GilbertoCastano-zg5ug 19 дней назад
Claro hablo de bomba de superficie
@GilbertoCastano-zg5ug
@GilbertoCastano-zg5ug 19 дней назад
Quedó atento a una respuesta muchas gracias
@juanzupan8897
@juanzupan8897 9 месяцев назад
la verdad, muy claro y didáctico, felicitaciones por el video
9 месяцев назад
Muchas gracias
@jliners6035
@jliners6035 9 месяцев назад
Y que pasa con el npsh requerido?
@AgustinLopez-ul9ue
@AgustinLopez-ul9ue 4 месяца назад
Estimado Ruben.. la bomba que utiliza para esta demostracion de que capacidad es...??? Yo tengo un abomba de 1/2 caballo ..cuanta altura puede succionar...???
@waltermagana6088
@waltermagana6088 2 месяца назад
Hola tengo mi pozo 18 metros de profundidad 16 de manguera tengo 4años con el pozo ase como 20 dias perdio precion la bomba esta nueva es de medio caballo se pierde la presión
@MiltonPerengüez-g5h
@MiltonPerengüez-g5h Месяц назад
Cómo ago para que el agua salga de nueve metros de profundidad de siento setenta metros asia abajo
@j.andressanaguaray2244
@j.andressanaguaray2244 2 месяца назад
Alguien me ayuda .se puede reducir el diametro del tubo .o puede tener problemas en fuccionamiento ??
@JoseMiguelEspinosa-x1f
@JoseMiguelEspinosa-x1f 2 месяца назад
Tengo una bomba que succiona de una cisterna pero a 10 mts de distancia no tengo cadi caudal es mucha la distancia?
@piter01996
@piter01996 9 месяцев назад
Holaaa un saludo.. tengo una duda es que tengo una bomba (mistral 33 5m este es su nombre multicelular horizontal ) y quiero saber si es centrífuga o periférica por que estoy armando una hidrobomba pero a mi cliente le recomendaron esta bomba pero no estoy seguro 🥲
9 месяцев назад
Esa es una bomba centrifuga multietapas, saludos cordiales
@piter01996
@piter01996 9 месяцев назад
@ graciassss por tu ayuda creeess que la pueda usar en una hidrobomba? O mejor la cambio por una periférica?
@Locotruman
@Locotruman 5 месяцев назад
Hola , si necesito elevar 100 l/s , a un reservorio que está a 6 y 10 metros de distancia , podría usar una bomba de este tipo ?
@albertoramonacosta1212
@albertoramonacosta1212 4 месяца назад
Gracias por aclarar pense que daba mucho mas ya que tengo el pozo de 60metro de profundidad y andaba con un compresor o sea envia aire hasta el fondo y saca el agua y el centrifugo absorve directamente el agua y me llenaria en minutos pero todo tienen sus limites gracias maestro Arg
@simonmarquez768
@simonmarquez768 6 месяцев назад
Hola buen día ingeniero quisiera hacer su curso pero soy de Venezuela y no sé cómo pagarle
@emilioneyra10
@emilioneyra10 4 месяца назад
Entonces dependiendo del hp. se.considera para 7 u 8mts
@francerdelarosaramirez7430
@francerdelarosaramirez7430 9 месяцев назад
Líder bendiciones Puedo usar una bomba de jacuzzi para llenar mi tinaco?
@andresmacea2339
@andresmacea2339 3 месяца назад
Hola buenos dias si reduzco el Diámetro a 3/4 me podría succionar agua, ya que mi poso donde va instalada la moto bomba súpera los 8 metros, ayuda deme una solución
3 месяца назад
Por qué piensa que reduciendo el diametro va a succionar más profundo? Intente sorber líquido con un popote (pajilla) más fina para que se de cuenta que es más difícil hacerlo.
@delriocarlosm
@delriocarlosm 6 месяцев назад
Saludos cordiales excelente videos ,me gustaría hacer el curso on line sobre hidráulica y bombas que mencionas....exitos
6 месяцев назад
Gracias
@axelsantos2389
@axelsantos2389 4 месяца назад
Hola. Tengo una bomba centrifuga de 1/2 caballo marca evans. Cuantos metros puede subcionar
2 месяца назад
8 metros por lo regular
@giancarlo5083
@giancarlo5083 8 месяцев назад
Amigo, quiero bombear de un tanque de 200 ltrs del 1 piso al 3 piso aprox. 17 mtrs de altura, puedo comprar la bomba periférica 1/2hp o recominedas la centrigura d 1/2hp
@hugorojasrubio5685
@hugorojasrubio5685 7 месяцев назад
para 17 m de altura se requiere bomba de 1 hp. La centrifuga llenara el tanque elevado en menor tiempo.
@motolocura4004
@motolocura4004 7 месяцев назад
Hola a mi me hicieron una perforación de 60 metros con tiraje de 30 metros de caños el agua está a unos 27 metros para la succión pusieron una centrífuga común de 2.5 HP con el sistema de eyector en el fondo El problema es que muchas veces no sube el agua
7 месяцев назад
le recomiendo una bomba de pozo tipo lapiz para que supere ese problema. saludos,
@CarlosRivera-zm7kq
@CarlosRivera-zm7kq 4 месяца назад
no entendí...esos 7 mts. son contando los metros de abajo que succiona y los que necesito que suba al tinaco?
4 месяца назад
Son aparte
@simonmarquez768
@simonmarquez768 6 месяцев назад
Que son los M.C.A lo podría explicar más, gracias
6 месяцев назад
Metros de columna de agua. Una unidad de presión. Saludos.
@sergio09789
@sergio09789 8 месяцев назад
Tengo una bomba aqua plus de 1/2 hp de 1pulgada de entrada y salida ; succiona 8metros igual
8 месяцев назад
Es posible que si, depende de la.altitud geográfica, longitud de tubería de succión y la temperatura del agua
@cransaftvalve734
@cransaftvalve734 9 месяцев назад
-1 Bar es la presión mínima que se puede conseguir?. No podemos nunca conseguir -5 bares.
9 месяцев назад
No, nunca.
@LMHP1508
@LMHP1508 2 месяца назад
GRACIAS
@marcelosanti4092
@marcelosanti4092 6 месяцев назад
Con eyector cuanto puede levantar?
6 месяцев назад
Algunos hasta 25 metros
@juancaves5518
@juancaves5518 8 месяцев назад
Exelente explicación Tengo una pregunta Sí reduzco el diámetro de la tubería de succión aumenta el metraje dé succión o seguiría lo mismo????
8 месяцев назад
Si disminuye el diámetro desmejoran las condiciones
@LeonardoFabian-p5l
@LeonardoFabian-p5l 8 месяцев назад
Hola yo justamente hice eso con 1 bomba de 1 hp le instalé con un caño de 1" para poder succionar 15 mts y no pude le reduciré a un caño de 3/4 y ahí si funciono perfectamente
@omaguiaraldana
@omaguiaraldana 7 месяцев назад
@@LeonardoFabian-p5llo que sucede es que la tubería de 3/4" hace pasar menos agua que la de 1". Por tanto el pozo se vacía a una velocidad menor, suficiente para que se reponga el agua... Aparte que de 3/4" la bomba necesitas menos fuerza para subir el agua. Pero estoy seguro que a más de 9 metros no estás sacando agua.
@josedomingomoraismujica9114
@josedomingomoraismujica9114 7 месяцев назад
❤❤
@AlbertoReyesHernández-n1y
@AlbertoReyesHernández-n1y 6 месяцев назад
Buenas noches tengo una bomba bonasa de 1hp la puce aún pozo que tiene 9 metros de ondo pero saca poca agua
6 месяцев назад
Esta al límite, considere colocar una bomba con eyector o directamente una sumergible.
@AlbertoReyesHernández-n1y
@AlbertoReyesHernández-n1y 6 месяцев назад
@ pero higual puce una de 2 hp pero pasa lo mismo aque se devera
6 месяцев назад
@@AlbertoReyesHernández-n1y independientemente de la potencia la altura máxima está aproximadamente en 8 metros
@francovisioli812
@francovisioli812 Месяц назад
excelente, genio total
@SebastianPons-l2f
@SebastianPons-l2f 9 месяцев назад
Excelente como siempre
9 месяцев назад
Muchas gracias estimado Gustavo
Далее
🤯To what HEIGHT can A PERIPHERAL PUMP BRING WATER?
11:13
Watermelon magic box! #shorts by Leisi Crazy
00:20
Просмотров 28 млн
Wirtz pumps are really clever
12:05
Просмотров 14 млн
6 More Reasons to Beware of SMART Meters, Sean Polacik
24:25
Do Pumps Create Pressure or Flow?
10:38
Просмотров 1,4 млн
🤯Why is a SUBMERSIBLE WELL PUMP DAMAGED?
9:26
Просмотров 44 тыс.
Tipos de Bombas |  Succion de AGUA para POZOS
13:18
Просмотров 16 тыс.
🤯How to choose the CORRECT PIPE DIAMETER?
11:09
Просмотров 645 тыс.
🤯ULTIMATE FREE ENERGY WATER PUMP real test.
25:28
Просмотров 714 тыс.