1. 220V - 380V (voltage change method)
STEP.01
Turn off circuit breaker before changing the voltage.
STEP.02
Check the fuse and replace it with a new one when the fuse blows out.
STEP.03
Remove the 220V wire at the top of the fuse holder 380V wire.
STEP.04
Connect the motor wires 4,5 and 6 lines.
STEP.05
For DSA type, please connect motor line 4,5,6 line and W101 line of rectifier.
STEP.06
Finally, after removing the load limiter soldering rod, press “mode” and change the L and H values.
STEP.07
Please refer to the table and set the overload limiter setting according to the designated model and voltage. Overload limiter setting figures are different for same model with different voltage.
2. 380V- 220V (voltage change method)
STEP.01
Change the 380-220V T/R Wire connection as shown in the picture.
STEP.02
If you connect motor lines 1 and 6,2 and 4,3 and 5, changes will be completed.
STEP.03
Finally, after removing the load limiter soldering rod, press the mode and change the L and H values.
STEP.04
Please refer to the table and set the overload limiter setting figures are different for same model with different voltage.