230 kv open switch failure 

sciencekid17
Подписаться 294
Просмотров 209 тыс.
50% 1

Опубликовано:

 

27 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 103   
@SteveBrule982
@SteveBrule982 2 года назад
everyone in the comments is some kind of electrical expert and im sitting here wondering just how i got here in the first place
@johnalexander7490
@johnalexander7490 5 месяцев назад
The Force of The You Tube is immense ... resistance is futile !
@borntoclimb7116
@borntoclimb7116 3 месяца назад
​@@johnalexander7490 true
@bamaslamma1003
@bamaslamma1003 3 года назад
The objects sticking out at an angle on the left side are either vacuum or sulfur hexafluoride (SF6) switches that actually break the circuit before the blades start to open. Apparently the load breaking switches failed, allowing the blades to open "hot" (still energized), thus pulling the arc as they swing to the open position. The arc flashes to an adjacent phase and trips an upstream breaker, extinguishing the arcs.
@henryrollins9177
@henryrollins9177 3 года назад
Thanks..!
@von...
@von... 3 года назад
didnt know they use sulfur hexafluoride for that? are those SF6 switches ever field-serviced, or would complete new & sealed units be put in place?
@tristanhill110
@tristanhill110 2 года назад
@@von... they're filled in the factories. If they go bad they have to be completely replaced.
@lwkite
@lwkite 2 года назад
Those are Joslyn vacuum interrupters on that switch. At that voltage they are supposed to be used for line dropping not interrupting load.
@edge1289
@edge1289 2 года назад
@@lwkite exactly right!
@teknikrota
@teknikrota 6 лет назад
It's a not failure. Switch opening under load.
@zarrow50
@zarrow50 6 лет назад
So what is happening?
@teknikrota
@teknikrota 6 лет назад
Clive Ellis If you open the switch on energized and under load,it making arc. It's normal but wrong. Must before open breaker,after open switch. Switches can't break the line under load. If open under load,as you can see It making arc...
@msmoonbeam91
@msmoonbeam91 6 лет назад
WHY are they doing it and does it cause a power failure somewhere?
@ToothyGus
@ToothyGus 5 лет назад
@@msmoonbeam91 This is a switch just like a light switch in your home. But because of the high voltage the switch has to be large and the positive and negative terminals have to be very far apart otherwise electricity just jumps across even if the switch is off. They are switching it off in this video but because of electrical load in the network, electricity does not want to 'turn off' so it makes an arc that you can see. makes sense?
@blakebeverly84
@blakebeverly84 4 года назад
ToothyGus Terrible analogy. There is no negative in A/C. Just like there’s no negative in your house and especially at your light switches.
@stevemackelprang8472
@stevemackelprang8472 2 года назад
Saw this happen at the Browns Ferry Nuclear plant in Alabama, early eighties ... scary stuff to be near.
@johnopfer8065
@johnopfer8065 3 года назад
That is what happens when the vacuum interrupter unit does not clear the way it should. All seven of the vacuum interrupters in each unit must open within a few milliseconds of each other. That did not happen here along with this impressive result.
@wesleyearl9010
@wesleyearl9010 3 года назад
OR IT WAS LOW ON SF6
@DaCoder
@DaCoder 3 года назад
Interesting that the smaller arms of the switch were pulled toward the other side while it was arcing. As soon as the arc broke they fall back.
@Hot_guy267
@Hot_guy267 3 года назад
Just the opposite. Lol.
@borntoclimb7116
@borntoclimb7116 3 месяца назад
Impressive sound of the electricity. I remember this Video and now im here in may 2024.
@adamc.sieracki4145
@adamc.sieracki4145 3 года назад
-Are you okay? -(Just soiled pants weak voice) I'm okay...
@christopherleubner6633
@christopherleubner6633 2 года назад
The circuit interuption device failed allowing the 3 phase switch assembly to open under load then two of the arcs connected tripping an upstream circit breaker. Believe it or not this was mild compared to some arc faults. Seen some that were blundingly bright with dripping molten metal like a welders arc on steroids frying bits of the substation. The worst case is an arc fault that starts in the power factor correction capacitor bank that continues tll the power transformer overheats and explodes.
@stuartschnare152
@stuartschnare152 3 года назад
Looked from this angle like the arc lasted too long and resulted in a phase to phase fault?
@seththemessenger5125
@seththemessenger5125 3 года назад
yeah, sounded like the fuse or breaker blew that could have been way worse
@dtiydr
@dtiydr 2 года назад
Yes but these arcs should never exist in the first place since there are special breakers inside them that break the electricity before these blades are opened so there will not be any arcs. Those breakers are special in that way that no arcs can form inside them.
@newsroblox23456
@newsroblox23456 Год назад
at the end when it arc sounds like a taser mixed with electrical arc
@richardday2893
@richardday2893 4 года назад
Best one I've seen so far!!
@music_only_in_hp6351
@music_only_in_hp6351 Год назад
Похоже, под нагрузкой выключали. Так может фаза на фазу переброситься.
@tracynation2820
@tracynation2820 3 года назад
Arc-cellent. 💙 T.E.N.
@daniel1478965
@daniel1478965 3 года назад
Are you okay?
@leofibonacci1170
@leofibonacci1170 3 года назад
Im okey
@lucyfer_the_bat
@lucyfer_the_bat 3 года назад
Im okay but thank you for asking
@tracynation2820
@tracynation2820 3 года назад
I'm okay. 💙 T.E.N.
@orangeofficer528
@orangeofficer528 4 года назад
that is not a failure thats how high voltage switches open
@connorthesledneck1398
@connorthesledneck1398 4 года назад
Not all the time. On those switches that contact that swings down is supposed to break the circuit immediately. But because they didn’t open the breaker first it kept arcing.
@msnehamukherjee
@msnehamukherjee 4 года назад
@@connorthesledneck1398 Speaking of which, why don't these Grid operators open the breaker first? So many YT videos of switch opening under full load. Why do they do it?
@kamikamieu
@kamikamieu 3 года назад
@@msnehamukherjee They wanted to flex about their equipment /s
@captspiff6922
@captspiff6922 3 года назад
This is NOT how a high voltage switch is supposed to work. Interrupter Bottle failure, probably exceeding its rating by trying to break load or excess loop current. See Joslyn Load Interrupter Attachments.
@jagmarc
@jagmarc 2 месяца назад
I can't see how this possibly turns out a failure as RU-vid puts two monetization adverts.
@bskklios4310
@bskklios4310 5 лет назад
0:20🤫
@ajsmusic723
@ajsmusic723 3 года назад
I HATE YOUR PICTURE
@NFSWIT
@NFSWIT Год назад
This is not a Electrical short circuit,this is is a test for the high voltage speed, But it is still very dangerous.
@5un5hine73
@5un5hine73 2 года назад
"I'm okay"
@zlatkojurkovac6981
@zlatkojurkovac6981 2 года назад
Anyone in the professional trade will say "WTF"? Normal disconnection of an loaded high voltage circuit - please do not make a fuss about it for a few fingers up. Thanks, BR Zlatko
@lancehobbs8012
@lancehobbs8012 2 года назад
This is part of an ordinary procedure?
@MaksunCece
@MaksunCece 2 месяца назад
Listrik saya 900 4a tapi untuk angkat beban 10a selama 2 jam cuma agak panas tapi gak jeglek MCB asli no modifan
@throwaway692
@throwaway692 2 года назад
Plasma is some cool stuff.... so to speak.
@lakairivera2316
@lakairivera2316 2 месяца назад
What was that weird loud honking sound 😳
@robertbarnett6879
@robertbarnett6879 3 года назад
Why was their a pop at then end and also was it just me or did it look like those arcs could have been sustained when the switches where fully open.
@supermarioisacat
@supermarioisacat 3 года назад
Yes, one of the arcs jumped across to it's neighbor causing a phase-to-phase short and upstream circuit protection tripped out on fault.
@jaypreddy8185
@jaypreddy8185 3 года назад
The “pop” you heard was the actual fault occurring. That is what stopped the arc. Some other device opened to extinguish the fault
@markneedham8726
@markneedham8726 2 года назад
The "Pop" is the sound with 230kv up your clacker.
@kalpeshwani8520
@kalpeshwani8520 2 года назад
The arrangement must be a sudden non insulating partition dropswipe cutting the arc at impending separation ..... ==≥🔰≤==
@richardbudd5334
@richardbudd5334 2 года назад
"You OK?" "I'm OK" other than my underwear
@muhammedaslamc.s3301
@muhammedaslamc.s3301 2 года назад
Did we only hear it 😆🤣🤣
@Mr324696487
@Mr324696487 2 года назад
nobody said Angus Young was playing here...
@jeppewie1206
@jeppewie1206 14 лет назад
real life hax
@patriotaconservador4231
@patriotaconservador4231 4 года назад
0:17
@180FiftyFive
@180FiftyFive 3 года назад
for people who cant wait 17 seconds
@shivakantdound3219
@shivakantdound3219 2 года назад
Are you ok
@chuckfischer7202
@chuckfischer7202 2 года назад
Don't try this at home.
@rtpask6233
@rtpask6233 2 года назад
I'll try it when I get a 230,000volt transformer at home :D
@midcenturymodern9330
@midcenturymodern9330 2 года назад
Amm, this is not a failure. It's normal operation.
@chrisgronert887
@chrisgronert887 3 года назад
I'm ok
@SodiumInduction-hv
@SodiumInduction-hv 2 месяца назад
SF6 Failure
@UAndFlower
@UAndFlower 4 месяца назад
It switched off after 3 years
@Electromaniac420
@Electromaniac420 Год назад
0:20 short circuit between 2 phases
@edge1289
@edge1289 2 года назад
Where was the failure?
@seththemessenger5125
@seththemessenger5125 2 года назад
at the end when the arc from one phase touched the other, tripped the breaker and all 3 phases shut off
@edge1289
@edge1289 2 года назад
@@seththemessenger5125 how do you know the breaker tripped?
@seththemessenger5125
@seththemessenger5125 2 года назад
@@edge1289 because all 3 arcs stopped right afterthe 2 phases short circuited
@edge1289
@edge1289 2 года назад
@@seththemessenger5125 like this one? 43 years in the trade, seen 230 disconnects open hundreds of times, that’s what they do. There is no was to know if there was a breaker operation by viewing that clip. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-_m7KbVjj7kc.html
@jojojorisjhjosef
@jojojorisjhjosef 3 года назад
That's failure alright.
@shawntepitts488
@shawntepitts488 2 года назад
OH Gosh
@user-rm4zi5jl3e
@user-rm4zi5jl3e 3 года назад
очень плохо,страшная дуга.
@LoganFamX
@LoganFamX Год назад
Backrooms
Далее
High Voltage Disconnect Switches 101
58:07
Просмотров 4,8 тыс.
Arcing Disconnect Switch
0:51
Просмотров 236 тыс.
Ajdarlar...😅 QVZ 2024
00:39
Просмотров 377 тыс.
COMMUNISM vs CAPITALISM: Who Made Better Power Tools?
24:39
Delivrance   1972    extrait Dueling banjos
4:44
Просмотров 769 тыс.
What If Light Was Really Slow?
8:03
Просмотров 2,5 млн
11 KV line fuse work
1:57
Просмотров 1,5 тыс.
Rookie Revue (1941)
7:47
Просмотров 2,2 млн
Switching 11kV VCB Tamco
7:34
Просмотров 2,5 млн
Arco elétrico
2:31
Просмотров 9 млн
Ajdarlar...😅 QVZ 2024
00:39
Просмотров 377 тыс.