1. Do not provide crank bar 2. The stirrups spacing should be maximum at supports 3. The angle. Of hook not designed for 135degrees 4.there is no designed for development length according to 0.87*fy*dia/4toeb*d 5.the Bending wires not tiet properly..... Thank you sir 😍
When you point out these mistakes, do they rectify them, or do they carry on and pour the concrete ? Nice to ‘now video as I’m in the middle of constructing my own house. 👍👍👍
Crank is not necessary in beams because it will be supported by thousands of bricks and that 90° rings are also not a problem as long as you mixed up the joints alternately
Dear, crank bar is not provided for shear resistance, but it is provided to encounter negative moment at the support or any position it needed. Secondly in SMRF design code recommends the spacing btw stirrup at the support should be less than 4in. And at the last, according to the code i never see 135 bending in stirrup of the beam. Thank you.
Would u mind turn on the CC so that words are on the screen be recorded as still picture and we can capture the main mistakes in this lecture without retyping? Please and TIA.
@@MasterCivilEngineering top bars are mainly there to hold up the stirrups, or for negative moment, or to reduce the neutral axis depth. The bottom bars resist the tensile stresses from bending action
yaar waisay samaj zara be nae aaye. aap asan language use kerain instead of technical terms. ta kay aik normal person be samaj jae. or saath main solution be be bataen, assan basha mai.