Тёмный

5 Biggest Mistakes in Beam - Big Mistakes in Steel Construction of Beam 

Civil Engineers
Подписаться 906 тыс.
Просмотров 134 тыс.
50% 1

Опубликовано:

 

6 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 62   
@99kevin99
@99kevin99 9 месяцев назад
Great video of the REAL WORLD...thank you!
@sampangibalakrishna5276
@sampangibalakrishna5276 3 года назад
1. Do not provide crank bar 2. The stirrups spacing should be maximum at supports 3. The angle. Of hook not designed for 135degrees 4.there is no designed for development length according to 0.87*fy*dia/4toeb*d 5.the Bending wires not tiet properly..... Thank you sir 😍
@bubblespark4265
@bubblespark4265 2 года назад
stirups minimum space at supports ..l/4 length..centre space more
@cliffriifiu1586
@cliffriifiu1586 4 года назад
Great lecturing, thank you.
@taffythegreat1986
@taffythegreat1986 3 года назад
When you point out these mistakes, do they rectify them, or do they carry on and pour the concrete ? Nice to ‘now video as I’m in the middle of constructing my own house. 👍👍👍
@nigelunruly3543
@nigelunruly3543 2 года назад
I would like someone to answer the question
@paagou3496
@paagou3496 20 дней назад
Crank is not necessary in beams because it will be supported by thousands of bricks and that 90° rings are also not a problem as long as you mixed up the joints alternately
@romanditobongalus7202
@romanditobongalus7202 3 года назад
Alayqumisalam. Watching from Philippines.
@JavedKhan-ny3pm
@JavedKhan-ny3pm 3 года назад
Can you show an example of 135 deg stirrup bars as most people are using 90 deg. ?
@mohammadtalhashah3260
@mohammadtalhashah3260 3 года назад
Dear, crank bar is not provided for shear resistance, but it is provided to encounter negative moment at the support or any position it needed. Secondly in SMRF design code recommends the spacing btw stirrup at the support should be less than 4in. And at the last, according to the code i never see 135 bending in stirrup of the beam. Thank you.
@sathishkaruppiah8788
@sathishkaruppiah8788 4 года назад
Thank you for the information brother.....do more videos bro
@tapasbhunia8895
@tapasbhunia8895 3 года назад
Sir make a video for design of cantilever beam and reinforcement details and SF, BF
@amacdavidz
@amacdavidz 4 года назад
its very clear. thanks for the info
@jongmagoncia1735
@jongmagoncia1735 4 года назад
That problem should have been prevented if there was an active site/resident engineer on that construction.
@yxhankun
@yxhankun Год назад
Would u mind turn on the CC so that words are on the screen be recorded as still picture and we can capture the main mistakes in this lecture without retyping? Please and TIA.
@AA-om4vb
@AA-om4vb 2 месяца назад
Amazing work
@hendrabangsawan875
@hendrabangsawan875 3 года назад
Waalaikum salam....god !! Salam from indonesia..
@MohamedJamir-pl8nw
@MohamedJamir-pl8nw 3 года назад
Crank not mostly given instead extra bars are given in L/4 at top reinforcement to counter shear at junctions
@sripalsri
@sripalsri 3 года назад
Good information bro thq alot 🤜🤛❤
@CivilEngineerss
@CivilEngineerss 3 года назад
Welcome 🙏
@vikrantparihar5962
@vikrantparihar5962 Год назад
Please make a video on how to check beam shutting line level & plumb bob
@vijaynarayan1936
@vijaynarayan1936 3 года назад
Greetings Sirji, Does the undersize steel and all the mistakes get certified by the building inspector before pouring concrete?
@edrisesmaely
@edrisesmaely 10 месяцев назад
what is the minimum and maximum space of stirrups? in L/4 and in the middle ?
@rolando3853
@rolando3853 4 месяца назад
You need hooks spliced to beam steel thus tying in beam to columb.
@SONUKUMAR-uo4di
@SONUKUMAR-uo4di 4 года назад
Sir Why captions is not available
@ramonplee
@ramonplee 3 года назад
Good commentary. Ur right.
@gurmailchanddhiman4062
@gurmailchanddhiman4062 2 года назад
Nice 👍👍👍👍👍 information sir
@sampangibalakrishna5276
@sampangibalakrishna5276 3 года назад
Sir why we are provided max steel reinforcement bare in bottom of simply supported beam
@ayoubenaciri
@ayoubenaciri 4 года назад
Thank you Sir 🙏🙏
@aglbakers
@aglbakers 3 года назад
Hello, I have some cracks that have developed. May I send you a video?
@paonamdineshmangang6179
@paonamdineshmangang6179 3 года назад
Sir can you please give some idea of 17.5 feet beam
@selvamv4680
@selvamv4680 3 года назад
Column striupps is also not there inside the depth of beam junctions...
@epindarkharkongor7127
@epindarkharkongor7127 2 года назад
Sir Please .show the drawing of crank bar
@ahmadmustafa3937
@ahmadmustafa3937 2 года назад
developing lenth kisay banaty hae?
@Faizkakar2233
@Faizkakar2233 6 месяцев назад
Yar hum ny gar Ka tamerr Kia Abi beAm kase deay chath Abi tak nhi banaaya hin
@Abu-Dhabi786
@Abu-Dhabi786 4 года назад
Good Job
@alongzorlymzorlym4032
@alongzorlymzorlym4032 2 года назад
Sir evn they did nt put the crank bar in beam why??
@ramonplee
@ramonplee 3 года назад
The problem there is that the engr who signed the design did not see it but he makes guarantee for the building.
@DesignReady.
@DesignReady. 4 года назад
This is Ileagal .... Report this construction
@MasterCivilEngineering
@MasterCivilEngineering 4 года назад
True
@royangraham5695
@royangraham5695 4 года назад
noted ‼️💯
@radhikat6496
@radhikat6496 2 месяца назад
Good
@aus2tigran
@aus2tigran 4 года назад
top bars transfer load to bottom bars?? that's not how beams work...
@MasterCivilEngineering
@MasterCivilEngineering 4 года назад
Yes dear
@aus2tigran
@aus2tigran 4 года назад
@@MasterCivilEngineering top bars are mainly there to hold up the stirrups, or for negative moment, or to reduce the neutral axis depth. The bottom bars resist the tensile stresses from bending action
@MasterCivilEngineering
@MasterCivilEngineering 4 года назад
Stirrups are used for shear while top bars are used for negative moment at supports
@manjunathkk9425
@manjunathkk9425 2 года назад
Suuuoper Tq u
@shahidghafoor3541
@shahidghafoor3541 Год назад
yaar waisay samaj zara be nae aaye. aap asan language use kerain instead of technical terms. ta kay aik normal person be samaj jae. or saath main solution be be bataen, assan basha mai.
@DesignReady.
@DesignReady. 4 года назад
This building will collapse
@bulbulebaagemadina
@bulbulebaagemadina 4 года назад
Walaikum assalam bhai
@MasterCivilEngineering
@MasterCivilEngineering 4 года назад
Video solutions of civil engineering questions here
@epindarkharkongor7127
@epindarkharkongor7127 3 года назад
Thank you sir do more vedio
@ramzysaikadatu7350
@ramzysaikadatu7350 4 года назад
The hook. That’s one of the mistake
@MasterCivilEngineering
@MasterCivilEngineering 4 года назад
Right bro
@Canada4Israel
@Canada4Israel 9 месяцев назад
Okay
@williamsgiancarloyenquecar189
@williamsgiancarloyenquecar189 3 года назад
el gancho de los estribos no es correcto
@johnbrando2666
@johnbrando2666 7 месяцев назад
Not ok amigo
@noslen6077
@noslen6077 3 года назад
You know why it's all mistake? Ba cause some already it budgets is in the pocket of the foreman
@rickyguade3304
@rickyguade3304 4 года назад
Okay okay okay okay
@sathishkaruppiah8788
@sathishkaruppiah8788 4 года назад
All of them are mistakes.....
@MasterCivilEngineering
@MasterCivilEngineering 4 года назад
Beam is full of mistakes bro
@viosog9661
@viosog9661 3 года назад
Etrierii nu sunt corecti , nu ai etrieri in noduri ,ciocuri la barele de la grinzi
Далее
3 Big Mistakes in Slab Construction on Site
8:08
Просмотров 19 тыс.
Why Retaining Walls Collapse
12:51
Просмотров 3,1 млн
Structural Shapes Ranked and Reviewed - Which one Wins?
15:34
COMMON MISTAKES IN CONSTRUCTION - PART 1
14:27
Просмотров 2,1 млн
Why Buildings Need Foundations
14:51
Просмотров 3,5 млн
The actual reason for using stirrups explained
9:01
Просмотров 787 тыс.