what is 5p10 in ct
5P10 means the maximum permissible limit of error (accuracy limit) is 5% at 10 times rated current (Accuracy Limit Factor). CT will give ratio error of only 5% even if fault current reaches 10 times the nominal value (In), after that CT will start to saturate.
Thank You
Electrical Technician
Electricaltechnician02@gmail.com
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
My gadgets for RU-vid 📺
Camera 📸 For video Recording
amzn.to/3z3W9XM
Mic 🎤 For Sound Recording
amzn.to/3kpUyaK
My Laptop For Video Editing
amzn.to/3imBuqU
Tripod Stand
amzn.to/3BajZmn
Overhead Stand For Recording
amzn.to/3z1rzhm
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Some Electrical Product For Your Home
Programmable Daily/Weekly Digital Timer
amzn.to/3z4tBgF
Wifi Control Smart Plug top
amzn.to/3dAZrJA
amzn.to/3hcO6Sr
Multimeter for electrician
best - amzn.to/3w7Vbry
Low Price - amzn.to/3wfF1MC
Water Level Controller
Single Tank - amzn.to/3xdcrwY
Double Tank - amzn.to/2UnvJAX
Motor Starter
2 HP Motor Starter - amzn.to/366AlhL
2 HP Motor Starter - amzn.to/3xhVtxw
Toolkit For Electrician
amzn.to/3AmK1T5
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Download pdf from telegram Channel
telegram.dog/ElectricalTechnic...
Connect with me in FB Page
/ electricaltechnical
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Related Video Which you must watch
Transformer Cooling Method
• 7 Types of Transformer...
Interview Question Answare
• Electrical Question Wh...
Star Delta Starter Control Wiring
• Star Delta Starter Con...
Over and Under Current Protection
• Over And under voltage...
MCB Trip Indicator
• TRIP Indicator Circuit...
Type of MCB
• B C D K Z Type of MCB ...
Auto off Switch Board
• Auto OFF Timer Switch ...
#ct
#ctratio
#CTClass

Опубликовано:

 

19 июл 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 22   
@bipinpanuly642
@bipinpanuly642 3 года назад
Bahut behtreen smjhaya sir or itne chote video hi mujh jaise back benchers ko easily samjah aatey hai or yaad bhi rehte hai thnx sir
@munnaeducationcare623
@munnaeducationcare623 5 месяцев назад
Thanks sir
@vaibhavtiwari1346
@vaibhavtiwari1346 3 года назад
Great info.. 🙌🙌🙏
@justwelltariang2456
@justwelltariang2456 3 года назад
Thankyou bro nice presentation. 👍
@rmylifethought6154
@rmylifethought6154 3 года назад
Good information 👍
@jagdishpatel493
@jagdishpatel493 3 года назад
Nice
@ramashankeryadav9492
@ramashankeryadav9492 3 года назад
Nice explanation Sir
@jaysinhsomase8184
@jaysinhsomase8184 3 года назад
5p10 Beacuse its max current is 10000 When fault occurred in the feeder then maximum current flow in feeder Initially 10000 A current is near than 20000A
@cgogoi8952
@cgogoi8952 2 года назад
My protection CT is of 5P class, it doesn't have any accuracy limiting factor/instrumental safety factor. My question is 5% composite error for what value of primary current of ct. Thanks in adv.
@hnxmadridup8563
@hnxmadridup8563 3 месяца назад
5p20
@sourabhmore7286
@sourabhmore7286 18 дней назад
5p10
@thakurvisheshrajput514
@thakurvisheshrajput514 2 года назад
5P10
@Guddu-jo7wh
@Guddu-jo7wh 3 года назад
5P20 Becoz rating of fault current is maximum in both accuracy
@jagdishpatel493
@jagdishpatel493 3 года назад
Oen relay kya hi
@ramsharma3772
@ramsharma3772 3 года назад
5P20 ही रहेगा क्योंकि इसका परसेंटेज एरर कम है
@mitubarik3361
@mitubarik3361 3 года назад
5% error matlab kya hai sir
@munnaeducationcare623
@munnaeducationcare623 5 месяцев назад
5p20
@bipinpanuly642
@bipinpanuly642 3 года назад
5P10
@user-hn5tg6hd4x
@user-hn5tg6hd4x 5 месяцев назад
5p20
@rajkumarhanje2521
@rajkumarhanje2521 Год назад
5p20
@jeeimran7329
@jeeimran7329 3 года назад
5p20
@babbushaikh7310
@babbushaikh7310 3 года назад
5p20
Далее
Разоблачение ушные свечи
00:28
Просмотров 472 тыс.