6 Reasons to Avoid Oversized HVAC Systems 

Energy Vanguard
Подписаться 992
Просмотров 1,1 тыс.
50% 1

Oversized heating and cooling systems are far more common in American homes than are properly sized systems. Here are 6 reasons why you should insist on proper sizing when you install new heating and cooling systems in your new home or when you replace the system in your existing home.
Energy Vanguard does HVAC design across North America and can help you get the right system for your home and your needs. See our website here:
www.energyvang...
Chapters
Intro - 0:00:05
Reason #1 - 00:51
Reason #2 - 01:29
Reason #3 - 02:25
Reason #4 - 02:48
Reason #5 - 03:29
Reason #6 - 03:55
Closing - 07:09
All images and video here are copyright Energy Vanguard with the following exceptions:
Woman in jacket and gloves: Jerzy Kociatkiewicz, CC 2.0 license, www.flickr.com...
Noise image from old ad: 1950sUnlimited, CC BY 2.0, www.flickr.com...
Cash: 401(K) 2013, CC BY-SA 2.0, www.flickr.com/...
Hygrometer: Sally Hunter, CC BY 2.0, www.flickr.com...
Manual J & Manual S: Air Conditioning Contractors of America

Опубликовано:

 

28 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 2   
@kennethdean4349
@kennethdean4349 3 дня назад
Thank you Allison. I share your posts with lots of people, in the trade and out.
@coldfinger459sub0
@coldfinger459sub0 2 дня назад
I have yet and have never found a properly sized system installed in the house yet. I’m still looking. That’s not even talk about undersized duct work . I think the last time I ever found a properly sized ductwork. Was when the original house that was built in 1940 had a gravity furnace, hard sheet metal ducting that was all wrapped in asbestos still excellent condition. Was designed for 160,000 BTU furnace . Design for a house with no insulation in the ceiling no insulation in the walls old wooden windows with the weights in the window sash. Most of the offshoot duct runs to the floor mount grills were 10 inch in diameter . The old house has had insulation blown into the walls, insulation blown into the attic. All the windows have been replaced with glaze vinyl windows. . And a contractor connected 40,000 BTU furnace directly to the 36“ x 28“ Plenum . Under this condition, it would be the most correct by accident overkill size ductwork that was original . . And 40,000 BTUs in a 1200 square-foot home in San Francisco is still way overkill and MORE than DOUBLE the size needed .
Далее
First Look: Octopus Energy Cosy 6 Heat Pump Install!
22:12
How a Variable Air Volume VAV System Works
16:54
Просмотров 113 тыс.
ТАРАКАН
00:38
Просмотров 531 тыс.
We finally APPROVED @ZachChoi
00:31
Просмотров 8 млн
The Mini Split - REINVENTED.
31:23
Просмотров 325 тыс.
You're wasting money on heating! Use your A/C!
17:11
Просмотров 533 тыс.
Why I Chose InSoFast for My Basement
11:12
Просмотров 1,6 тыс.
Performance Duct Design & Installation: Advanced DIY
46:23
Data Center HVAC Systems
20:14
Просмотров 122 тыс.
VAV Variable Air Volume - HVAC system basics hvacr
13:53
AC Types 3D
7:11
Просмотров 11 тыс.
ТАРАКАН
00:38
Просмотров 531 тыс.