Тёмный

760.33 Surge Protection (for Fire Alarm Control Panels) 

Ryan Jackson
Подписаться 30 тыс.
Просмотров 2,3 тыс.
50% 1

Fire alarm control panels must now have surge protection on their line side.

Опубликовано:

 

8 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 26   
@DarenSpinelle
@DarenSpinelle Год назад
For 2026, let's do 150 days!!! who's with me???
@chrisf3875
@chrisf3875 Год назад
Appreciate the time and effort that you put in doing these videos, your humility and personability really made them a joy to watch. I was just in Florida on a project, and they were required to put a surge protector dedicated for the fire alarm control panel circuit no closer than 3 ft from it. Here's an idea, how about a series on tables & chats in the N.F.P.A. but first enjoy what's left of Summer! 😊
@iaov
@iaov Год назад
I came to your channel late but am looking forward to going back and watching the whole series. At one time I hated anything to do with the NEC but job responsibilities forced me to. gain a passing familiarity with it. A few years later i studied for and passed the master electrician exam for Wisconsin and worked in the field for many years. It grew on me and although I have been retired for 8 years now I still find the code fascinating. Your presentations have been very well done and I have enjoyed them immensely. Thank you and I hope you do more of this in the future... George(iaov)
@johnwayne4790
@johnwayne4790 Год назад
I'm a massive fan of yours Thank you for everything you do, helping simpletons like me every day.
@jefffielder2429
@jefffielder2429 Год назад
Thank you all the knowledge you shared and the time it took to do it thanks again
@jmcg6160
@jmcg6160 Год назад
Thanks for a great series of videos!!
@electricaltyler5998
@electricaltyler5998 Год назад
well, I'm going to have to go back some of this I missed but hey thanks for all the intel Ryan!
@denverbraughler3948
@denverbraughler3948 Год назад
The applause goes to you, sir! Thank you for another NEC series.
@Buddha24
@Buddha24 Год назад
Thank you very much. I found this to be of great value. Loved the short, to the point, clear knowledge sharing form someone who knows it very well. You made it as fun as one could I think. You are a great teacher.
@estradacarlos2461
@estradacarlos2461 Год назад
I got no words to thanks u , 💯💯💯💯💯💯💯 love all u do for me all of us great job It was very informative and i learned a lot
@erinocean3845
@erinocean3845 Год назад
Thank you for such a wonderfully explained and completely thorough overview of the changes this year. I have watched every single one of your videos in the series and I've even been able to share some valuable knowledge with my colleagues pertaining to issues we've encountered lately. My boss was impressed by my ability to site things he didn't even know had changed and now he comes to me asking code rules since I "seem to know it pretty well" so thank you Ryan for helping make me a more valuable resource at work!
@RyanJacksonElectrical
@RyanJacksonElectrical Год назад
Thanks for sharing that with me, Erin. That seriously made my day. :)
@mackfisher4487
@mackfisher4487 Год назад
Thanks good job Hope you keep this series available for future reference, my village is still on 2017.
@educationpower1823
@educationpower1823 Год назад
Ryan, you have done a fantastic job hands down. This 100 days series will have a nd is saving thousands of lives and equipment. Your efforts are valued and appreciated and will be put to good use. It's true, the best way to learn something is to teach it to others. Thank you Robert from Omaha
@alexwurstner6101
@alexwurstner6101 Год назад
This has been awesome! I hope you do more series like this in the future, whether it be code changes or just teaching the code in general
@dan9372
@dan9372 Год назад
You made it look easy
@dhucek9998
@dhucek9998 Год назад
Thank you for your time !!!
@billyg4985
@billyg4985 8 месяцев назад
Good stuff budd I learned a lot and got a kick from u few videos back when u second guessed yourself and said let me see if I'm smoking crack or not lol. overall very informative stuff budd
@bobbyh6293
@bobbyh6293 2 месяца назад
You kicked butt✊🏽
@kodykinsella
@kodykinsella 3 месяца назад
watched them in two days for journeyman test
@RyanJacksonElectrical
@RyanJacksonElectrical 3 месяца назад
Good luck!
@ChadwickFerguson
@ChadwickFerguson Месяц назад
I made it. I only want to pass my master exam. After that you can have the code back. I thought that they weren't going to need surge protection for diesel fire alarm control panels. /s
@BelieverSenora
@BelieverSenora 3 месяца назад
Hi sir, I have one doubt Now i am doing one small player project.clinent provided list of material.they chose fcc924 panel total 38 devices among 38 4 surge protector.i have pump room, telecom,IT and ground room where to install surge protection.pls guide
@ScottShayAKAFifty50g
@ScottShayAKAFifty50g Год назад
Hello Ryan, sorry to ask on this format but I’m in a bit of a bind. I have a small transformer-(a separately derived system)- 10KVA single phase 480 stepping down to 120/240. My question is on grounding and bonding. The transformer is feeding a 100 panel board with a 100 amp main in the panel. The MBJ (green screw) is attached in the panel. My neutral point is X2-X3 in the transformer. It is connected to ground. Ground is connected to the source feeding the transformer, and grounded to building steel. I am not sure if I need to send another ground out to my new panel, or just use the neutral conductor as the green screw is attached. Im worried about the parallel path I will create. Any tips or video references? Thank you for all you do.
@RyanJacksonElectrical
@RyanJacksonElectrical Год назад
If the transormer is connected to ground you need to remove the green screw in the panelboard.
@ScottShayAKAFifty50g
@ScottShayAKAFifty50g Год назад
@@RyanJacksonElectrical thank you sir!!!! I believe that was the case, and I need to install a supply side bonding jumper. My confusion lies in the term “the first means of disconnect” as this will be the first means of disconnect for the new system. However upon reflecting and studying this morning I believe that may only apply to services although I may be wrong. Thank you for your prompt response and your many great services. I hope one day to be half the code guy that you are!!!
Далее
Article 724 Class 1 Circuits
13:03
Просмотров 2,5 тыс.
700.5 Transfer Equipment (emergency systems)
8:04
Просмотров 1,5 тыс.
Fake watermelon by Secret Vlog
00:16
Просмотров 10 млн
Мама знает где все документы
00:21
750.30 Load Management
10:34
Просмотров 1,7 тыс.
Article 726 Class 4 Fault-Managed Circuits
9:16
Просмотров 1,4 тыс.
Raceway (conduit) Fill Pt 1
39:38
Просмотров 13 тыс.
700.11&700.27 Class 2 Systems (emergency systems)
8:45
Fake watermelon by Secret Vlog
00:16
Просмотров 10 млн