A10VO DFLR PUMP REXROTH - Better explanation of the operation of POWER CONTROL 2/3 

Oleohidráulica Avanzada by Ric Rach
Подписаться 5 тыс.
Просмотров 27 тыс.
50% 1

Become a member of this channel to enjoy exclusive videos:
• Members-only videos
/ @oleohidraulicavanzada
The best explanation of the operation of the Rexroth A10VO DFLR pump with power control.
WhatsApp message: +51 961284096
web: oleohidraulicavanzada.com
DELIVERY OF CLASSES via Tems or Meet, according to available and coordinated schedules, payments via Yape, Western Union or on the same RU-vid channel.
INQUIRIES AND REPORTS: oleohidraulicavanzada@gmail.com
Basic oil hydraulics in the Ric Rach style: 30 soles/hour (Peru) - 8 dollars/hour (other countries).
Learn about the topics you want, such as:
• Fixed and variable open circuit pumps: operation, curves, formulas, efficiencies, brands Vickers, Eatón, Rexroth, Parker, Danfoss, or whatever brand you have.
• Closed circuit variable pumps (hydrostatic): Rexroth, Danfoss, or whatever brand you have.
• Pressure valves: reliefs, reducers, counterbalances, SUN hydraulics brands, among others.
• Flow valves: Flow regulators, priority, among others.
• Distributor valves: Type NG, simple valve block, introduction to the load sensing compensated valve block, orbit roll type, others.
• Physical laws, erosion, cavitation in valves, maintenance, hydraulic tips, simple failures in hydraulic systems.
• Introduction to electrohydraulics and proportional hydraulics.
• And about the topics you propose.
Advanced oil hydraulics in the Ric Rach style: 30 soles/hour (Peru) - 8 dollars/hour (other countries).
Learn about the topics you want, such as:
• Load Sensing system in pumps.
• Load Sensing system with power control in pumps.
• Load sensing compensated valve block.
• A10VO pump and its multiple configurations.
• Pumps: Rexroth, Parker, Danfoss, Vickers, Eaton, others.
• Engines: Intermot, gerotor…
• Valve block: Gresen, Parker, Rexroth, others.
• A6VM engine and its multiple configurations.
• Interpretation of advanced hydraulic plans, mobile and stationary machinery.
• Interpretation of plans for the equipment you work with (approx. 3 hours).
• Electrohydraulics and proportional hydraulics.
• LUDV Rexroth system
• Cat 3PC System
• Others.
Consulting, equipment failure analysis, advice: 30 soles/hour (Peru) - 8 dollars/hour (other countries). Generally in 1 hour I resolve the error, or query. It is paid after the fault or query is resolved. Advice on hydraulic theses.
The best way to increase your level of knowledge is through teaching from another expert person (according to Vygotsky and the zone of proximal development).

Опубликовано:

 

12 мар 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 23   
@luisalbertoramoschamana3247
@luisalbertoramoschamana3247 3 года назад
Gracias por el aporte
@hazaelarvizu6401
@hazaelarvizu6401 11 месяцев назад
Como puedo calibrar las valvulas? Contar las vueltas?
@dhdhdnjd8644
@dhdhdnjd8644 2 года назад
How much is the Rpm right of the ram
@ajitnayak2126
@ajitnayak2126 2 года назад
señor, perdón por mi pobre idioma español. No sé español, solo trato de hablar contigo sobre mi problema, Hola señor, yo mismo Ajit Nayak de INDIA, tengo la bomba Rexroth A10VSO100-DFLR-31R. En unos días, mi equipo reemplazó el kit rotativo de esta bomba. Te pregunto pl. guiarme a través de la configuración de la presión, el control de flujo y la configuración óptima de la válvula de detección de carga. mi máquina CNC requiere pre. Es un motor de 3200 PSI, 50HP que se utiliza en este sistema. Gracias Ric Rach y equipo.
@oleohidraulicavanzada
@oleohidraulicavanzada 2 года назад
Mándame un correo para apoyarte. oleohidraulicavanzada@gmail.com Envía el plano o esquema hidráulico. Slds. Send me an email to support you. oleohidraulicavanzada@gmail.com Send the plan or hydraulic diagram. Slds.
@juliolopezgutierrez6204
@juliolopezgutierrez6204 5 месяцев назад
En caso que ya tenga presión desde el arranque puede haber problema con ese compensador?, tengo un problema no puedo desaparecer la presión desde el arranque, accionó un actuador y se baja la presión,
@oleohidraulicavanzada
@oleohidraulicavanzada 5 месяцев назад
Hola, se tiene que analizar el circuito hidráulico para ir directo al problema, oleohidraulicavanzada@gmail.com si lo tienes lo mandas. Slds.
@diegorodelo3392
@diegorodelo3392 2 года назад
Tengo una gran duda las perforaciones que tiene el plato vasculante en el extremos que se comunican con la lubricacion a que lado deben ir
@erickponteramos8615
@erickponteramos8615 Год назад
Para el lado , que se encuentra el piston de posicionamiento
@juliusiglesias1405
@juliusiglesias1405 2 года назад
Sir what the minimum and maximum pressure for this model A10V071 DFLR1 thank u so much
@oleohidraulicavanzada
@oleohidraulicavanzada 2 года назад
Según el data sheet RS 92 701/10.07 (puedes encontrarlo en google), presión de trabajo no mayor a 280 bar, pero puede soportar picos de hasta 350 bar. ¿Que significa esto? que Rexroth recomienda lo uses hasta la presion de 280 bar (para que tu bomba te dure y este ok), pero algunos elevan la presión mas de 280 bar, pero esto desgastara o deteriorara mas rapidamente a la bomba, ya que el rango de picos de presion que surjan pueden ahora sobrepasar los 350 bar. Saludos According to the data sheet RS 92 701/10.07 (you can find it on google), working pressure not higher than 280 bar, but can withstand peaks of up to 350 bar. What does this mean? that Rexroth recommends you use it up to a pressure of 280 bar (so that your pump lasts and is ok), but some raise the pressure more than 280 bar, but this will wear out or deteriorate the pump more quickly, since the range of peaks of pressure that arise can now exceed 350 bar. Greetings
@cleitonricardoqueridobagli8850
@cleitonricardoqueridobagli8850 2 года назад
Gostarias de saber como faço está regulagem no loca? Tenho que regular primeiro a pressão de alta ou não ?
@oleohidraulicavanzada
@oleohidraulicavanzada 2 года назад
Hola, eso se regula con un caudalimetro y midiendo la presión, es decir con un probador hidráulico dandole carga, en donde se grafica la curva PxQ. Regular el compensador o la load sensing, son otras regulaciones aparte a esa regulación del control de potencia. Por eso indico es facil desregularla y recuperarla al azar, pero el punto exacto se obtiene con la curva PxQ. Slds. Olá, isso é regulado com um medidor de vazão e medindo a pressão, ou seja, com um testador hidráulico dando uma carga, onde é plotada a curva PxQ. A regulação do compensador ou sensor de carga são outros regulamentos além do regulamento de controle de potência. Por isso indico que é fácil desregulamentá-lo e recuperá-lo aleatoriamente, mas o ponto exato é obtido com a curva PxQ em uma bancada de testes. Slds.
@betoordonez5694
@betoordonez5694 2 года назад
Saludos una pregunta xq al arrancar mi maquina le twngo q mover el votw para q arranque esta dura la bomba tambien me gira segido un metal de la bomba
@mahendraniwas2505
@mahendraniwas2505 8 месяцев назад
Windlass hydraulic pump rexroth A10VSO DFLR hyd pump ...while starting pressure is 50 bar and when lowering pressure goes up to 140 bar while operating DCV handle...once we release the handle to stop position... slowly pressure drops and goes to 50 bar again..and after that not able to do lowering operation...but heaving operation working but slow... pressure dropping till 20 bar....pls suggest some inputs
@oleohidraulicavanzada
@oleohidraulicavanzada 8 месяцев назад
Hello, there is a control failure in the pump, I recommend you take those pumps to someone who knows (hydraulic workshop) since they have power control and are calibrated on a test bench. The symptom that the pressure takes a while to drop in neutral may be that the LS restrictors are contaminated (LS-Bypass). And the lack of flow pressure control, the pump power control may have moved and that is calibrated on a test bench. Try very carefully to check the load sensing, disassemble it, check its spring, and restrictors, be careful that any restrictor falls out of the load sensing inlet pipe, which has one. If you can send me photos and the hydraulic plan oleohidraulicavanzada@gmail.com Greetings.
@ajitnayak2126
@ajitnayak2126 2 года назад
Hello sir, Myself Ajit Nayak from INDIA, I have Rexroth A10VSO100-DFLR-31R pump. before few days my team replace rotary kit in this pump. i request to you pl. guide me to set up Pressure, Flow control as well as load sensing valve optimum setting. my CNC machine required pre. is 3200 PSI, 50HP Motor using in this system. Thanks Ric Rach & Team.
@goghiumarian6270
@goghiumarian6270 3 месяца назад
Salutare din Romania,am un escavator Volvo 3,5t si are aceiași pompă. Problema este că atunci cînd se fac 2 comenzi împreună moare motorul,specific sa umblat la reglajele de pe supapa LS , îmi poți spune ce ar putea fi mulțumesc anticipat
@oleohidraulicavanzada
@oleohidraulicavanzada 3 месяца назад
Ce se întâmplă este că atunci când reglați mai mult supapa LS, creșteți debitul disponibil în pompă. Această creștere determină creșterea puterii hidraulice și tinde să oprească motorul diesel. Trebuie sa stii cand este diferentialul Load Sensing furnizat de producator, ca sa il poti regla asa. Iar procedura pe care ți-o dă producătorul ar trebui să fie în manual, care piston trebuie mutat pentru a verifica presiunile pompei și a LS, și a obține diferența. In orice caz, trimite-mi planul hidraulic sau manualul pentru a-l localiza mai bine la oleohidraulicavanzada@gmail.com sau wasap +51 961 284 096. salutari
@bhikhubhajadeja7427
@bhikhubhajadeja7427 Год назад
Hi
@sajitheeshwara5070
@sajitheeshwara5070 2 года назад
Plz add English subtitle
@oleohidraulicavanzada
@oleohidraulicavanzada 2 года назад
Translated. Slds.
Далее
Еду за гитарой…
01:00
Просмотров 149 тыс.
Load Sensing system operation 1/3
14:13
Просмотров 32 тыс.
SEMINARIO: COMPONENTES OLEOHIDRAULICOS
2:01:00
Просмотров 23 тыс.
Operation of the hydrostatic hydraulic system
9:50
Просмотров 78 тыс.
Variable displacement hydraulic pump
34:00
Просмотров 44 тыс.
A10VO DFR and DFR1 REXROTH PUMP - "The three states"
11:20
Flujo de Bomba de desplazamiento variable - Pump DV
44:03
Rexroth A8vo Sr control function
8:36
Просмотров 11 тыс.