Here a demonstration video on how to turbine wash an ABB TSP44-F32 Turbocharger. Which is in accordance with the manufacturer's instructions.
Key Notes:
ABB TSP44-32 Turbocharger
Exhaust turbine water washing is performed with its set parameters to be effective and prevent damage. This cleaning procedure involves thermal-shocking to remove carbon deposits and it's only applicable to this kind of turbocharger design.
Set Parameters:
Exhaust Temperature: 400 to 450 degree Celcius
Engine Load: 20% to 40%
Water Pressure: Above 0.2 Mpa
Duration: 3 times - 15-30 seconds (depending on the turbocharger performance)
Always refer your manufacturer's turbocharger instruction manual for proper turbine washing cleaning

Опубликовано:

 

15 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 16   
@makinistangmandaragattv5560
@makinistangmandaragattv5560 2 года назад
Very informative Idol...pa shout-out po
@D-solut
@D-solut 2 месяца назад
Hi. After waterwashing the turbine side of the generator the exhaust inlet temperature going to turbocharger become higher and now the turbocharger is whistling. I followed the same procedure since it's also Yanmar and it has same instruction in the manual. Should I waterwash again or could it get worse?
@balanayharry
@balanayharry 2 месяца назад
@@D-solut you could do it again. If things get worse better to check the turbocharger by opening up. Discuss it with your chief engineer for proper disassembly procedure.
@ВладХацер
@ВладХацер 2 года назад
What about drain line? Abb usually have it and before turbine cleaning need to check if it clean.
@balanayharry
@balanayharry 2 года назад
For this ABB model, it doesn't have any drain lines, and its operation - maintenance manual is not mentioned any drain lines. Yes, there are some model turbochargers that have drain lines that must be checked for the accumulation of carbon deposits that could clog the drain.
@dahuda26
@dahuda26 3 года назад
1.should the turbocharger switched off if it needs to do this process? 2.if the tc switched off, also the engine too right ? or just tc ? 3.your experience its so meanfull, thanks !
@balanayharry
@balanayharry 3 года назад
Turbo Charger washing in the process is needed to be in operation. unless turbocharger is for overhaul the engine must be shut down and cooled down.
@dahuda26
@dahuda26 3 года назад
@@balanayharry thanks man, and whats the material for turbine washing ?
@balanayharry
@balanayharry 3 года назад
@@dahuda26 water
@ayandamkhize860
@ayandamkhize860 3 года назад
Why is the turbocharger exhaust temperature after turbo lower than temperature before turbo when the engine is running on load.
@balanayharry
@balanayharry 3 года назад
​@@ayandamkhize860 The turbine is a power developing device. As the high pressure exhaust is directed on the blades, it's kinetic energy is converted into the rotation of turbine blades by providing a thrust to them, this leads to drop in pressure and temperature. ... then as the pressure decreases the temperature decreases.
@doom2095
@doom2095 Год назад
Is the generator in service or connect? Or disconnect in bus while doing turbine wash?
@balanayharry
@balanayharry Год назад
Its already connected and partially serviced at 20% to 40% load.
Далее
Overhauling an ABB Turbocharger TSP44-F32
13:17
Просмотров 16 тыс.
boiler economizer cleaning
12:26
Просмотров 1,3 тыс.
5 Reasons Why Turbine Wash Required?
7:14
Просмотров 8 тыс.
Lifeboat weekly checks(aniket)
16:51
Просмотров 29 тыс.
IHI/ABB Turbo Charger Overhaul Model TPS 52
24:11
Просмотров 8 тыс.
YANMAR GENERATOR TURBOCHARGER (RH-113) OVERHAUL
22:48
L21/31 Dismantling of Cylinder Unit from Engine
5:13