Тёмный

Ac choking problem solution,Capillary tube choking problem reason 

Fully4world
Подписаться 700 тыс.
Просмотров 233 тыс.
50% 1

Ac choking problem solution,Capillary tube choking problem reason in urdu hindi
Aslam o alikum Dosto apko is video mai bataya hai k ac ager chok ho raha ho to kis waja sy ac choking problem krta hai ao capillary tube ko kesy set krty hai
#AC_CHOKING_SOLUTION
------------------------------------------------------------------------------------------------------
Subscribe: / fully4world
Azam Ali Channel: goo.gl/4Hgxh4
Instagram Follow: / azamali256
Facebook Page: www.facebook.c...
Azam ali FB ID: / smak.azam
Website:: www.fully4worl...
Compressor Blast How and why
• Compressor Blast How a...
Air conditioner contactor wiring,Connection || Fully4World
• Air conditioner contac...
Split air conditioner installation full video step by step in Urdu/Hindi
• Split air conditioner ...
Compressor test with series circuit, and direct start compressor in Urdu/Hindi
• Compressor test with s...
Magnetic contactor easy testing,checking in Urdu & Hindi
• Magnetic contactor eas...
Latest technology and science and more funny videos
we are upload for you

Опубликовано:

 

14 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 311   
@syedakbar9487
@syedakbar9487 2 года назад
Subhanallah mahaallha allhamdlillah janab very good video excellent jazakallah khair
@fully4world
@fully4world 2 года назад
Share krdo video
@artivedi3887
@artivedi3887 2 года назад
AAP jaisey expert jo main dikhaney aur theek karney ke 1500apne ghar pe deti
@JavedKhan-rg8hy
@JavedKhan-rg8hy Год назад
Azam. Bhai. Thank. U. Love. U. Vidio. K. Liye
@fully4world
@fully4world Год назад
Jazak Allah
@mohammedtabjeel2570
@mohammedtabjeel2570 5 лет назад
iske bare me itna nahi pata tha ,shukriya bhai
@HakeemKhan-tq8sg
@HakeemKhan-tq8sg 11 месяцев назад
❤❤❤ زبردست 👍👍👍👍
@RizwanAnsari-rf7jh
@RizwanAnsari-rf7jh 6 лет назад
Bahut achha hai bhai aise hi experiment karke hamari help karte rahe. Bahut bahut shukriya bhai
@javeedhvactechnician7760
@javeedhvactechnician7760 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-prn2UXvyiGk.html
@CCCreationsCorner
@CCCreationsCorner 4 года назад
thank you azam bhai aik ac nai demagh kharab kar diya tha same problem detect hogaiye hai aap ka bohot bohot shukriya.
@javeedhvactechnician7760
@javeedhvactechnician7760 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-prn2uxvyigk.html
@aziztechnicalgroup1952
@aziztechnicalgroup1952 6 лет назад
Very nice video sar Aap bahut acchi video banate hai 1 dum acche se samajh me aata hai aapka video
@haazalkhan3917
@haazalkhan3917 5 лет назад
Apki har video interesting hone hi hoti hai
@shahrukhsaifi1101
@shahrukhsaifi1101 5 лет назад
Sir apne sahi bola mere sath ho chuka h
@NatureAndBeauty-p7i
@NatureAndBeauty-p7i Год назад
Nice 👍 information
@ammarahmad3859
@ammarahmad3859 4 года назад
Very nice bhi
@arslanmalik7258
@arslanmalik7258 5 лет назад
Allah ka shukr ha bht ki ha asi problem clear
@shaikhaejazali4774
@shaikhaejazali4774 2 месяца назад
achha 😮
@RajKumar-gn9fz
@RajKumar-gn9fz 3 года назад
Kya copresser ka cambulater laga hotta h vo bhi choke ho sakta h ager cercat me jyda pani a Jaya to
@Musatech4U
@Musatech4U 6 лет назад
Sir refrigerator me choking problem qu hota hai ,aur iska solution kya hai please sir Bata degeyga. Sir petrol se pipe falshing kar sakte hai kya
@ameenbutt7790
@ameenbutt7790 2 года назад
Allah karim ap ko apny hifzo aman me rakhy
@murtazahasan5
@murtazahasan5 4 года назад
Very nice video sirji
@shahaalam2112
@shahaalam2112 2 года назад
tnz vaya
@mayaanawan3132
@mayaanawan3132 3 года назад
Assalam o alaikum Azam bhai
@artivedi3887
@artivedi3887 2 года назад
Aabhi kaa pipe use kar saktey hain Jo AC mein use hotaa hai ??? matlab..aur. Kahan se pipe letey hain aur.."sabhi kaa"..matlab kyaa
@MehrazAli-j7m
@MehrazAli-j7m 8 месяцев назад
Outdoor and indoor me preser aa rahi hai sir pr gas charges nahi hota sir please comment please
@HafizAnas-s1e
@HafizAnas-s1e 2 месяца назад
Aslamo. Alikum. Azam. Bhai. 1 ton. Ka. Ac. Ha. Non inwetor. Usma. Compressor. Dusra. Lagya. Ha. Auotar or indor. Ko. Falish. Kar. K. Ges. Charj. Kari. Ha. Mgr. Sir. Ac. Cooling. Krta. Phr. Cooling. Chor. Deta. Ha. Dishcharj. Paip. Kabi. Garam. Hota. Ha. Kabi. Thanda. Hojta. Ha. Or. Sir. Geej. Lagao. TU. Oil. Bhot. Zada. Bhar. Ata. Ha. Sir. Compressor. TU. Dusra. Laga. Ha. Phr. Bi. Ya. Sai. Kam. N. Kara. Compressor. Ka. Pareshor. Bi. Pora. Ha. Sir. Plz. Kia. Mala. Sir. Mana. Phely. Bi. Apko. Comments. Kra. Ha. Plz. Sir. Ye. Madla. BatAdijy. .
@halimhalim6678
@halimhalim6678 Год назад
Ye to thik hai Side ka taka to lg jga pr bich me kese lgega sir
@artivedi3887
@artivedi3887 2 года назад
Jaisey aapne pipe mein itni capillaries ghussayeen kya wahan se gas leak nahin nikalegi
@sanjitparjapat47
@sanjitparjapat47 Год назад
capacitor pe Runnig starting me kase tarq de bhai Or kis problam de tarq deya jata Please 🙏🙏 tel me bhai
@TayyabHasnain-4430
@TayyabHasnain-4430 2 года назад
Thank u sir
@hindurashtrrawat483
@hindurashtrrawat483 4 года назад
Thank you mitr
@غلاممرتضٰیمہر
@غلاممرتضٰیمہر 3 месяца назад
Bhai inverter outer indoor ke begair kasy chalain
@reehanansari2584
@reehanansari2584 5 лет назад
Very good Sir
@UniqueFameStar
@UniqueFameStar 5 лет назад
Sir ye capillary tube indoor k alawa kahi or b lagi hoti h kyaa ,, Jaisa ki aap ki ek dusri vdeo me jo capillary wash ki usme to outdoor wla discharge valve bhi fit tha ,,
@UniqueFameStar
@UniqueFameStar 5 лет назад
Btaiyye sir
@jaffarsiddique9918
@jaffarsiddique9918 6 лет назад
shukriya bhai nice video
@baljitpal4347
@baljitpal4347 3 года назад
thnxxx
@shanurefrigeration9780
@shanurefrigeration9780 6 лет назад
Vary nice bhayjan
@yogitech3524
@yogitech3524 5 лет назад
Sir haaf ya anther kopar pip ko hum as filtar use kar sakte h....... firige m ...ya ac m..
@pkzyotube8561
@pkzyotube8561 6 лет назад
Bahat zabar dasst by
@yarmuhammadkorejotech9013
@yarmuhammadkorejotech9013 5 лет назад
Masha Allah Azam bhai
@javeedhvactechnician7760
@javeedhvactechnician7760 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-prn2UXvyiGk.html
@asimkhanzada6032
@asimkhanzada6032 4 года назад
Azam bhai section aur dicharg preshar compressor ka hota hy yah gass ka
@RehanPathanS.T.F-u6r
@RehanPathanS.T.F-u6r Год назад
Split AC window AC ka capital size aur Kitna lagta hai Jankari chahie Sar ji
@hafizmuzammil9966
@hafizmuzammil9966 5 лет назад
nice and thanks
@saffanchippa9538
@saffanchippa9538 3 года назад
Bhai aap kahase ho
@aartivedi6889
@aartivedi6889 Год назад
Flushing mein to gas nikaalney ki baat kartey hain??
@mandeepsingh3531
@mandeepsingh3531 6 лет назад
Nyc Video hai sir ji
@ap.destiny.cooling
@ap.destiny.cooling 5 лет назад
Bhai jaan Agar capillary filter chok rehta hai tu Patli pipe ice jamta hai kya
@sedamrefrigeratorservice
@sedamrefrigeratorservice 6 лет назад
Masha Allah Bhai
@shahalamkhan9056
@shahalamkhan9056 6 лет назад
assalam o alikum bhai very helpful video thanks bhai Allah Hafez
@javeedhvactechnician7760
@javeedhvactechnician7760 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-prn2UXvyiGk.html
@junoshaikh5036
@junoshaikh5036 Год назад
Agar ye choke up raha to discharge per ice aata hain kya bhai plz tell me.
@junoshaikh5036
@junoshaikh5036 Год назад
Agar capillary choke rehti to 1/4 ke service valve se pressure nahi aata tha. But wahase aa raha hain.
@aartivedi6889
@aartivedi6889 Год назад
Aap dilli mein hain to kyun nahin kartey hamara
@fully4world
@fully4world Год назад
Ham Lahore sy hai
@alisaikh1866
@alisaikh1866 6 лет назад
Aajam bhai asslamu alaikum ..aajam bhai.. Indoor unit ki mukammal vairing bata dijiye please 👏👏👏👏👏👏feel
@tanveerarif6399
@tanveerarif6399 3 месяца назад
Mashallah
@fully4world
@fully4world 3 месяца назад
jazak Allah
@hemantmali7347
@hemantmali7347 6 лет назад
Very nice sir m tech multi service
@aartivedi6889
@aartivedi6889 Год назад
Bhai sab kaat ke hi nikaal diyaa to ..sab kaatna hai ab??
@manishsaini8173
@manishsaini8173 6 лет назад
Bahut badiya
@narindersingh-me4pb
@narindersingh-me4pb 5 лет назад
ke wadiya.......
@ZeeshanAli-zg6bb
@ZeeshanAli-zg6bb 4 года назад
Sir g humy kasy pta chaly ga k chok hai ac
@artivedi3887
@artivedi3887 2 года назад
Kitni ki cappillaries aati hain aur vo pipe ka tukdhaa ..kitney measurement ka hota hai kisi jaanein khareedney ke liye
@aartivedi6889
@aartivedi6889 Год назад
Capillary. Cool hai behad thandi nahin kya gas kum hai yaa choking hai..kyunki aagey kaa condensor thanda nahin hai Jo aata hai gas gas bol Raha hai pichle saal se abhi Tak gas poori khatm nahi. Hui ye kyaa hai kum bhi kyun hai
@charanjitsingh7462
@charanjitsingh7462 4 года назад
Sir kya hum winter season main r22 gas charge kar sakta hai
@alfredoavila2858
@alfredoavila2858 5 лет назад
Estan buenos tus videos pero no te entiendo nada saludos de veracruz mexico
@sukhjeetss1541
@sukhjeetss1541 5 лет назад
thanx sir ji.....
@mayaanawan3132
@mayaanawan3132 3 года назад
I have some question about capillary tube
@javeedhvactechnician7760
@javeedhvactechnician7760 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-prn2UXvyiGk.html
@tuo.marito
@tuo.marito 4 года назад
LG 36000 btu ki gas 45 he par us me gas or nai berh rehi..or suction pipe p ice he kyaa reason ho skti he ataa de...indoor unit .ka blower ...coil filter sab clean he..is k bawajoob b kiu..?
@jilankhankhan5295
@jilankhankhan5295 2 года назад
Nice 👍
@mdadil4142
@mdadil4142 6 лет назад
Nice information
@Imrakhan313
@Imrakhan313 5 лет назад
Sar pilyz ek video banao jisme full ac acembaly ho plz sar
@shahidammar1327
@shahidammar1327 5 лет назад
Azam bhai indoor ki coil oper se gram hai neche se thandi ho rahi hai gus bi puri hai service bi kia hoa hai lakin coling bohat kam ha is ki kia waja hai aur us ko kase theek karain.
@SandeepKumar-xr7hp
@SandeepKumar-xr7hp 6 лет назад
Nice video bro
@YK-gu9xo
@YK-gu9xo 3 года назад
I want to know about window ac unit not split ac. Window unit is choking so what to do ??? Kya Window AC aur split AC dono ke liye same method use karein ???
@javeedhvactechnician7760
@javeedhvactechnician7760 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-prn2UXvyiGk.html
@mdsarfarazansari8323
@mdsarfarazansari8323 6 лет назад
اسلام علیکم کیا حال ہے اعظم سر سوال یہ ہے کہ کمپریسر چل رہا ہے اور نیچے سے لیکر اوپر تک کمپریسر ٹھنڈا ہورہا ہے مشین میں کیا مشکل ہے جواب دیجئے نوازش ہوگی
@alexajisamuval176
@alexajisamuval176 6 лет назад
I have one doubt this is capilory or distributor
@sartazahmad4420
@sartazahmad4420 6 лет назад
THANKS AZAM BHAI
@javeedhvactechnician7760
@javeedhvactechnician7760 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-prn2UXvyiGk.html
@sudeshputran69
@sudeshputran69 6 лет назад
Very good
@fahadkhanji8001
@fahadkhanji8001 3 года назад
Sar tum kaha se ho
@fully4world
@fully4world 3 года назад
Pakistan Lahore
@khurramahmad5004
@khurramahmad5004 4 года назад
Boss its a distributor and that's not a right solutions of cheng the distributor because if we will use the pipe 5/8 or 1/2 then indoor getting the sounds like siti after gas filling I have also getting same work
@jollyscaria1922
@jollyscaria1922 2 года назад
New dis buter fixing modifaied making other some line fixing chock ed probles sovling
@anayatullah8361
@anayatullah8361 6 лет назад
Very naic
@VijaykumarVijaykumar-vi5rl
@VijaykumarVijaykumar-vi5rl 2 года назад
Nitrogen flash karle pipe saf hojagi
@zubairahmad4633
@zubairahmad4633 3 года назад
Bhai muthhe pcb kaam shihkana hai .
@mohdasifaliali3967
@mohdasifaliali3967 6 лет назад
Bhai inverter AC PCb and compressor test batiyea p/z
@sameerkk5768
@sameerkk5768 5 лет назад
Nice work bro
@javeedhvactechnician7760
@javeedhvactechnician7760 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-prn2UXvyiGk.html
@junaidansari7162
@junaidansari7162 6 лет назад
AAZAM BHAI VIDEO TO ACHI HAI LEKIN BHAI LEAK HONE K CHANCE HAI NA GAS
@hassanshaikh2491
@hassanshaikh2491 6 лет назад
Hahaha g bhai bat sahi hay sahi tarah soldring nhi ho pay ge center say leak k chances zaida hay
@Apna_uae
@Apna_uae 6 лет назад
bhai achi trah garam kar k soldring karo kuch nai hoga soldring rod khud ba khud phail jayega ab itna b garam nai karna k caplry pipe e melt ho jaye😂😂😂😂
@junaidansari7162
@junaidansari7162 6 лет назад
SHEEDA 007😒😒 SUNTER SAY HONE K CHANCE HAI BHAI LEAK
@Apna_uae
@Apna_uae 6 лет назад
@@junaidansari7162 bhai main kia hun nai hota center se b soldring rod achay se guma do ahista ahista achi trah kam mushkil h but hai kamal ka cooling b zyada ho jati h
@coldroomsourabhcoldroomsou6014
very2 thanks boss
@pakistancoolsevice2618
@pakistancoolsevice2618 5 лет назад
Bohat lamba kadia sirf iske andr jali hoti he jo blok hojati 1/4 ka pip nikal kar jali ko tode de kam hojae ga
@junaid_raja
@junaid_raja 5 лет назад
Brother my #winowAc compressor is too noisy..how to solve this issue...plz guide
@patelsafu36
@patelsafu36 6 лет назад
Thanks
@deepakjain-nz2nk
@deepakjain-nz2nk 2 года назад
आजम जी डेटन पैनासोनिक एसी रनिंग 50 पीएसआई से ज्यादा नहीं शो कर रहा है और कॉलिंग नहीं हो रही है मोटे पाइप पर आइस भी जम रही है क्या प्रॉब्लम हो सकती है
@ashishchaturvedi2211
@ashishchaturvedi2211 5 лет назад
Bhai mera window AC on hota hai normally Lekin 5 min baad compressor trip ho jata hai.....kya problem ho sakta hai ....plz reply
@tirathraj1839
@tirathraj1839 6 лет назад
Nice video
@DreamElectrical
@DreamElectrical 6 лет назад
Azam Bhai Air conditioner heating mode PE kaam kese karta he
@hassanshaikh2491
@hassanshaikh2491 6 лет назад
4 way reviving wall ke help say bro
@ParvezKhan-su4lr
@ParvezKhan-su4lr 6 лет назад
@khanmax5557
@khanmax5557 6 лет назад
good bhai
@mkkhatri4642
@mkkhatri4642 6 лет назад
Bhai ap pipe jo lagaye chote chote pipe k bice mein welding kaise karenge bich mein toh Welding nahi Hua toh lekh hone ka chance hai ..ab ap hama welding kar k bata de
@sheikhmaria6102
@sheikhmaria6102 5 лет назад
Suniay vai yaha par stainar da du to koye dikkat hoga
@mohammadyaseen9004
@mohammadyaseen9004 6 лет назад
caplery to outer pr laga hota he ye to cooling disribute krta he na
@rhichardblaze39
@rhichardblaze39 2 года назад
That is not proper maintenance it will not distribute properly that is not a window that you can jump for maintenance process the distribution has metering device inside which regulate the type of refregirant you will use in system
@saleemkhan1707
@saleemkhan1707 6 лет назад
nice video sir make video about inveter compers how to start witoh pcb bord sir
@hassanshaikh2491
@hassanshaikh2491 6 лет назад
Well done question bro use China PCB for temporary start and check inverter compressor because inverter compressor variables system not run with out PCB bord
@alishahnawaz95
@alishahnawaz95 5 лет назад
@@hassanshaikh2491 china pcb kya aap us ka photo send kar saktai hai
@MdIrfan-yd8qf
@MdIrfan-yd8qf 5 лет назад
Bhai Woh capleri Nahi Hain liquid line divider Hain capleri out door mein laga Hain 0.60 ka
@Apna_uae
@Apna_uae 6 лет назад
2.5 ton L.g split ac hai wo vaccum pay jata hai gas dalo to 10psi se oper nai jata discharge pay filter laga huwa hai wo b okay hai 5 minutes chalnay k bad discharge pipe pay ice ban na start ho jati hai ...... koi slution.. Adnan from dubai thanks
@IkramKhan-nq2rs
@IkramKhan-nq2rs 6 лет назад
0509977286
@rahulgajare6148
@rahulgajare6148 5 лет назад
Choke hoga bhai
@suhailsalmani2891
@suhailsalmani2891 6 лет назад
V good sir
@RanveerKumar-vo8ob
@RanveerKumar-vo8ob Год назад
🙏
@Ajaykumar-tp9nq
@Ajaykumar-tp9nq 6 лет назад
nice sir
@javeedhvactechnician7760
@javeedhvactechnician7760 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-prn2UXvyiGk.html
@SameerAhmad-wm2ei
@SameerAhmad-wm2ei 5 лет назад
the voids between the small pipes can cause leakage... but nice video , good job
@javeedhvactechnician7760
@javeedhvactechnician7760 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-prn2UXvyiGk.html
@manojmishra4828
@manojmishra4828 5 лет назад
V good
@priyankanain2469
@priyankanain2469 3 года назад
Bhai 1.5 ton ka AC MA 55 no ki caplary laga di Compressor Bahuat heat hova ha
@kdhadda9726
@kdhadda9726 2 года назад
60 lgao
Далее
How To Identify Capillary Tube Is Blockage
18:51
Просмотров 38 тыс.
How To Flush Air Conditioning System
10:03
Просмотров 413 тыс.
zamil package unit trip Reason & Solution
9:21
Просмотров 20 тыс.