Тёмный

AC Indoor and Outdoor Maximum Cooper Pipe|Ac ma kitna pipe Daly.एसी इनडोर और आउटडोर अधिकतम कॉपर पाइप 

AC Master
Подписаться 2,8 тыс.
Просмотров 5 тыс.
50% 1

AC Indoor and Outdoor Maximum Cooper Pipe|Ac ma kitna pipe Daly.एसी इनडोर और आउटडोर अधिकतम कॉपर पाइप.
vedio Create by
Ac Master
Ali Imran
ac indoor to outdoor pipe length minimum and maximum
ac indoor to outdoor wiring
copper pipe
cooper and hunter
ac copper pipe length maximum size
split copper pipe size and ton
air conditioner copper pipe size and ton hindi,outdoor ac
ac pipe maximum size
rf indoor out door control wiring
minimum copper pipe length for split ac
maximum pipe length of ac
copperu
ac copper pipe length minimum size,indoor ac
copper pipe full tutorial
hand bending copper
indoor to outdoor wiring
what is the optimum distance between indoor and outdoor
ac indoor outdoor wiring
1 outdoor 2 indoor
2 indoor 1 outdoor
where to install ac outdoor unit
1 outdoor 2 indoor ac
1 outdoor 2 indoor ac hindi
modif ac 1 outdoor 2 indoor,daikin 1 outdoor 2 indoor
single phase ac indoor outdoor wiring
outdoor to indoor unit wiring
parallel ac 1 outdoor 2 indoor
what's the optimum distance between indoor and outdoor tamil.
Three phase Power control Safety System introduction. part B
• Introduction of 3 phas...
Compressor Cutting
• 2 Ton Ac Bristol Compr... FM(Ac Master)

Наука

Опубликовано:

 

29 окт 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@TechAshfaque02
@TechAshfaque02 4 дня назад
@mujahidali2018
@mujahidali2018 9 месяцев назад
bht informative vedio
@obaidish
@obaidish 9 месяцев назад
Very nice video sir thanks for sharing
@acmasters4170
@acmasters4170 9 месяцев назад
Ap ka shokria ap na mujy idea dea
@mujahidali2018
@mujahidali2018 9 месяцев назад
Love❤ from ralawpindi
@acmasters4170
@acmasters4170 9 месяцев назад
Thanks you bahi g thanks you
@raghuveernishad8671
@raghuveernishad8671 Месяц назад
S .r 2 tan ka ac hain piping ki lambi hain 150 fit to kya chalega madhin
@acmasters4170
@acmasters4170 Месяц назад
Ab ke indoor unit or outdoor unit ke location Kaya matlb kon sa uper ha or kon sa nechy ha
@raghuveernishad8671
@raghuveernishad8671 Месяц назад
Indore unit 20 fit niche hain or ac ka pipe 150 lamba hai to koi problem ayega s.r please reply
@raghuveernishad8671
@raghuveernishad8671 Месяц назад
Ac 2 tan ka hain
@Tdtechnician_32
@Tdtechnician_32 Месяц назад
1.5 spliac ac me 45 miter laga skte hai
@acmasters4170
@acmasters4170 Месяц назад
G g 40 ka bhe laga sakty Hain 45 ka bhe laga sakty Hain . 30 say 35 uf 1 ton k leay 40 say 45 1.5 ton 50 say 55 uf 2 ton 60 say 65 uf 2.5 ton
@acmasters4170
@acmasters4170 Месяц назад
Sory kisey or ka answer ap send ho gaya nahi sir atna length bilkul glat ha
@ValueAdder06
@ValueAdder06 2 месяца назад
Bro ye jo ghar dikhaya h iska map mil jayega
@acmasters4170
@acmasters4170 2 месяца назад
Ok
Далее
Flaring pipa AC cepat dan presisi
1:29
Просмотров 74 тыс.
AC copper pipe | Malasiya vs Mandev
3:43
Просмотров 29 тыс.
Самая редкая видеокарта NVIDIA
1:00