ACS Ventilation - More Than One Appliance 

Pass Your Gas
Подписаться 1,8 тыс.
Просмотров 2,1 тыс.
50% 1

passyourgas.blogspot.com/
How to calculate the ventilation requirement when there are multiple gas appliances in a room. You will have exam questions and assessment questions on this subject.

Опубликовано:

 

21 мар 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 24   
@CarlGuymer1
@CarlGuymer1 26 дней назад
Thank you! I passed my ACS at Brookehouse last Thursday....these videos you have made have helped me over the past year while I have been preparing for the exam.
@7magicful
@7magicful 5 месяцев назад
The room size of 30m3 is too small for 3.7kW flueless fire (3.7kW x 22.22 = 41.1m3) At Risk situation. But video is very helpful. Thank you. Love your channel.
@eazyrat
@eazyrat 2 года назад
found this channel just in time thanks!
@passyourgas
@passyourgas 2 года назад
You’re welcome. If you’re struggling with anything let me know and I’ll pop a vid up to help you!
@zakariaalzubair6654
@zakariaalzubair6654 2 месяца назад
thank you so much helpful
@hvacgas5292
@hvacgas5292 2 года назад
Very helpful thanks 👍.. Would love to see vid how to read data badge for appliance working pressure, gas rate.
@passyourgas
@passyourgas 2 года назад
Thanks for that. I’ll stick an explanation of data badge reading up for you in the next week or so.
@pro-powerflushing
@pro-powerflushing Год назад
Got my 5 years acs next month honestly you are very helpfull thanks so much for these videos 👍👍
@passyourgas
@passyourgas Год назад
I made them just for that! It’s so hard when you’re just doing one thing all day to remember the stuff you learned 5 years ago. Good luck and if you want anything let me know and I’ll make a vid. Cheers and thanks.
@pro-powerflushing
@pro-powerflushing Год назад
@@passyourgas you a mystery man I can’t see your name but yea it’s nice to see these videos I do mostly powerflushing not a lot of gas work so yes it slips my mind but then the 5 year thing comes round very quickly thanks again I’ve got more videos of yours to watch also 👍
@user-yw6qb9tt7t
@user-yw6qb9tt7t 2 года назад
Great video. 👍
@richardmcleod8604
@richardmcleod8604 Год назад
thank you so much
@abdulh63
@abdulh63 2 года назад
Hi, great video again. Wanted to ask, if I fitted a gas hob in a property and there was a boiler and a fire. What would a visual check on them require me to do, especially on the fire? Thank you
@passyourgas
@passyourgas 2 года назад
Hi Abdul. Thanks for the compliment. Re the visual checks, do you use the Viper book? If so it’s all on page M42. If not let me know and I’ll create a quick video for you…in fact I’ll be doing this anyway thanks to your question…
@abdulh63
@abdulh63 2 года назад
@@passyourgas thank you so much. I'm just wondering if you have to take the fire out and do a flue flow and spillage on a visual. I always assumed a visual is something quick and it seems a lot to do when you're only there to fit a hob. Would love a video on it, thanks again
@passyourgas
@passyourgas 2 года назад
@@abdulh63 It will be up by tomorrow for you. I’ll tell you straight off that you don’t need to do flue flows etc but there are 2 sets of rules depending on what you have done in the house…vid tomorrow.
@shredder8000
@shredder8000 2 года назад
Say u have a scenario, a flueless space heater in a 30m3 hallway, a 30kw gross warm air unit, no window but a door direct to outside, I’ve worked out both the fire & boiler need 100cm2 of ventilation each, can u add 2 categories together
@passyourgas
@passyourgas 2 года назад
If the warm air heater is also flueless it belongs in the same category as the fire so you add them together. If it’s open flued then it’s in a different category and you choose the one that needs most ventilation…cheers
@shredder8000
@shredder8000 2 года назад
@@passyourgas what about if they both come out the same, so they both require 100cm2, do u just pick 1 or add them both together,
@passyourgas
@passyourgas 2 года назад
@@shredder8000 Hi shredder…no, if you have two categories needing 100cm then you just use 100cm…you only ever use one category…remember these are MINIMUM ventilation requirements, you can put 200cm in if you want, as long as you don’t go under 100cm….hope that helps..
@shredder8000
@shredder8000 2 года назад
@@passyourgas ok kool, thank u 🙏
@zabiullahkhorsand6757
@zabiullahkhorsand6757 2 года назад
30m3 not 30m2 = room size Thanks
@passyourgas
@passyourgas 2 года назад
Well spotted `zabiullah, a slip of the tongue, thanks for pointing it out. 😀
@Mark-fl1hg
@Mark-fl1hg Год назад
Also not pointed out, is that you would not be able to fit a 3.7kw flueless fire into a room of only 30 m3 volume. There is a maximum allowance of 45 watts per m3 of heated space (45x30), so the maximum heat input permissible for this appliance in this particular room, would actually be only 1.35 kW
Далее
ACS Essential - Flue Terminal Types Explained
17:30
Просмотров 1,5 тыс.
ACS Essential - Installation Sizing
13:55
Просмотров 1,2 тыс.
ventilation ACS revision quiz.
7:09
Просмотров 2,9 тыс.
Water powered timers hidden in public restrooms
13:12
Просмотров 451 тыс.
Gas Rates Everything You Need to Know
29:16
Просмотров 5 тыс.
ACS Ventilation Made Easy
9:41
Просмотров 2,1 тыс.
ACS Fire Types and their ventilation
9:03
Просмотров 2,7 тыс.
ACS Essentials - Notching and Drilling Joists
18:17
Просмотров 1,2 тыс.
Measuring Gas Ventilation | Gas Tutorial
11:53
Просмотров 1,6 тыс.
Tightness and Let-By Tests and Tracing Leaks
20:12
Просмотров 2,5 тыс.