Amazing 100 Year Old Mansion Steam Heating System 

The Apprentice Survival Guide
Подписаться 17 тыс.
Просмотров 34 тыс.
50% 1

Join this captivating narrative as we step into the past, exploring the charm of a century-old mansion still adorned with its original heating system.
Our adventure unfolds in this remarkable mansion, home to an authentic heating system that has stood the test of time. Delve into the enchanting world of old convective current heat registers, marveling at their craftsmanship and enduring functionality. Witness the vintage elegance of original radiators, each telling a tale of the mansion's rich history and the evolution of heating technology.
As we navigate through the majestic corridors, explore the intricate details of steam trap valves, each a testament to the ingenuity of early HVAC engineering. Marvel at the resilience of an old boiler feed tank, standing as a silent witness to the mansion's century-long journey through changing seasons and evolving heating practices.
However, our tale takes an unexpected turn as we address the need for modernization by "Replacing Gas Valves on a Commercial Steam Boiler." Explore the complexities of integrating contemporary technology into a historic setting, balancing the need for efficiency with the preservation of the mansion's unique character.
Through this storytelling, my aim is to provide viewers with a vivid and nostalgic experience of the HVAC profession. Whether you're a seasoned professional seeking to appreciate the evolution of heating systems or an enthusiast eager to explore the charm of vintage HVAC technology, this narrative promises an insightful and engaging journey through the complexities of "Replacing Gas Valves in a 100-Year-Old Mansion."
#hvac #boiler #apprentice

Развлечения

Опубликовано:

 

20 дек 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 103   
@ed6837
@ed6837 7 месяцев назад
That is a boiler alternating return trap. Basically a steam powered pump. That is an old vapor system that should run very low pressure. The alternating trap pumps water back into the boiler. It's all in the LOST ART.
@poohbear4130
@poohbear4130 7 месяцев назад
There’s an introduction to old school heating, reminds me of the old schools and apartments! Just a heads up when cleaning those burners you need to throw on a dust mask. It’s the by products of combustion are the ones that get you, I spent 32 yrs in the heating trade and what I know now is a cheap dust mask can go along way to saving your health! Man you don’t get the easy and clean ones, nothing like experience to teach a guy!
@paulwells-qe4fq
@paulwells-qe4fq 7 месяцев назад
Well said been doing this for 25 years. Nobody cares when you’re taking out asbestos filled boiler or dealing with a plug boiler that’s doing nothing but filling up the room with. Soot.
@raygunsforronnie847
@raygunsforronnie847 7 месяцев назад
And eye protection. Wire brush in the drill flinging 'stuff'.
@adamlagocki7224
@adamlagocki7224 6 месяцев назад
Hey there, the Sarco device is some type of boiler return trap. That's a two-pipe vapor/vacuum steam system. They're usually designed to run at no more than 8-10 oz steam pressure. One pipe steam systems have an A dimension on the return , which is fixed at 28" because there's always leftover steam pressure in the returns to help push the return water back into the boiler. Two pipe systems do not have steam pressure in the returns, and so they have a B dimension that has to be 30" per PSI of boiler pressure (the weight of the stacking water alone has to overcome the boiler pressure to force the water back in). A boiler return trap is an ingenious device that uses a float actuated steam valve and two check valves to "pump" the return water back in the boiler. As the boiler pressure rises, water backs up in the returns, fills the float chamber, and the float opens a steam valve which allows steam pressure into the device, which momentarily turns the B dimension into an A dimension, and pushes the return water through the check valve into the boiler. When the float level drops, the check valve keeps the water in the boiler, and the chamber waits for more return water to fill it up. This is a quick summary, check out the book The Lost Art of Steam Heating to learn all about two-pipe vapor systems and boiler return traps
@kevspicy
@kevspicy 7 месяцев назад
You explain the job so well that almost anybody could understand. Fun to watch, solid pacing, and overall great video!
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
Thank you so much for the awesome feedback! It’s very helpful to hear
@lnk4328
@lnk4328 7 месяцев назад
Just an FYI on that Honeywell V88 or V48 gas valve. The original brass compression vent fitting was an "Adjustable Bleed Valve Assembly" that you can use to control the opening speed of the valve.
@commonsense1907
@commonsense1907 5 месяцев назад
Great video. I used to live on the second floor of a 3decker with steam heat for the first 2 floors. Both boilers burned coal at first. The first floor boiler went from coal to oil to gas. The second floor boiler went from coal to oil. American Radiator radiators for the first floor. US Radiator radiators for the second floor. First floor boiler manufacturer Royal Steam Heater Co. Second floor boiler manufacturer The Putnam Co. Both boilers worked as of 2009.
@imark7777777
@imark7777777 7 месяцев назад
Yeah it's so nice to see stuff originally installed and not messed with and proper maintenance done not hacks more than temporary fixes.
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
absolutely, unfortunately i dont know how much longer this system will be running. eventually it will be ripped out and just a distant memory
@BaconJD420
@BaconJD420 7 месяцев назад
I love your videos, man keep up the great work, I’ve been a licensed plumber and heating contractor for 35 years you would not catch me dead with a cast-iron pipe wrench, aluminum all the way. I’ve even hit them with 5 pound sledge hammers they work just fine
@kameljoe21
@kameljoe21 7 месяцев назад
I have an old cast iron steam/hot water boiler in the garage. I looked for over 10 years and went and picked it up only to get it home to find out that someone had replaced all of the grates on the inside with rebar made stuff. The cast iron boiler is in great shape and could still be used as is for wood. My plan is to maybe install it in my new house. I am going to pull the home made stuff on the inside and use what is in there for bolts and mounts and have someone draw it up and build a proper grate. It does have the holes for the hot water tube. Just not the hot water tube. Find 6 matching steam radiators. I am going to install copper tube to go to all 6 of the rads 2 in each of the sections and then use wood to heat it. Expansion tank and all assoited valves and stuff along with a floor sink will be next to the boiler along with a wood rack that I hope will match. I have been looking for a some cast iron stuff to make a wood rack that would go along with the build. Some of the older stuff and this boiler has a back door which I do think can or was intended to be used with an oil burner and or automatic feed. I am going to glycol the system for -40f.
@Uticagreens
@Uticagreens 7 месяцев назад
When I was a kid (I am now in my 70s), my uncle had a coal fired steam boiler in Upstate Mohawk, NY. In below zero temperatures it heated the very large home so well; you would think that you were in Florida.
@georgejetson4378
@georgejetson4378 6 месяцев назад
I’ve done my fair share of disassembling messes like that and maybe you’re already aware of this but in case not, what works reasonably well for me is to heat the coupling to near cherry red, then quench rapidly in water. Got a 2 inch steam pipe apart with this method that was severely rusted.
@professorkiwi
@professorkiwi 7 месяцев назад
So satisfying watching this! Keep up the great work!
@gmguy156
@gmguy156 6 месяцев назад
You need to get yourself one of those small ridgid pipe vises. Does up to 2-1/2”. Also get yourself a 1/4 ton come a long, a couple shackles. Put the shackles through the handles of the pipe wrenches and use the come along to break it loose
@samuelaiken2570
@samuelaiken2570 7 месяцев назад
Loving your videos more and more everyday bro keep it up! I’m a commercial service tech, it’s nice to be able to learn some things from your videos. Been watching for a few months now. Merry Christmas!
@totaltech8246
@totaltech8246 7 месяцев назад
14:50 that’s a boiler return trap. I think Dan Holohan has a video about them on his Heating Help youtube channel.
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
Thank you so much for the info brother!
@geoffreyyoung5419
@geoffreyyoung5419 7 месяцев назад
Love your program keep up the great WORK.
@snaplash
@snaplash 6 месяцев назад
3:47 breaking the unions. Reminds of my water heater replacement last year. I ended up pulling the two (shorter) wrenches together with a woodworking clamp to finally break the 3/4" union loose.
@aglasserm1679
@aglasserm1679 7 месяцев назад
Your best video yet!
@homeauthorityllc
@homeauthorityllc 7 месяцев назад
Nice work - good video! I've seen way too many valve handles bent or cut off so short they are worthless. I've taken a number of them off, straightened them if needed, flipped them 180 degrees (if there are no obstacles on the other side) - all good. Also flipped a number of them that couldn't be turned off because of an obstacle.
@damionfragoso2655
@damionfragoso2655 7 месяцев назад
You have to love that convention heat
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
Worked like a champ!
@TheRAMBO9191
@TheRAMBO9191 7 месяцев назад
24 minutes lettts fkn gggooooo! I could watch these alot! You are entertaining
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
Thank you for all of the constant support brotha!
@TheRAMBO9191
@TheRAMBO9191 7 месяцев назад
No problem
@Fluxkompressor
@Fluxkompressor 6 месяцев назад
4:13 now that's what I would call a damn cool wallpaper
@theodorgiosan2570
@theodorgiosan2570 6 месяцев назад
Those "sections" look like Gold's Pin Indirect radiators. Yes the same Gold that invented the Mattress radiator in 1854. They are not repurposed boiler sections, and were quite popular in large houses.
@yfdfireman2
@yfdfireman2 5 месяцев назад
In two pipe steam, you don’t heed the air vents. Each radiator has a steam trap, those traps need tested because if 1 fails open it messes with the whole system. Easy way to see is heat the system up and you will see at least a 10 degree drop from the radiator to the pipe leaving the trap. Enjoy.
@carlosportilla7634
@carlosportilla7634 7 месяцев назад
Cool video man 👏👏👍🙏🏻🙏🏻
@stangaloski4208
@stangaloski4208 7 месяцев назад
Ok... im jealous as hell. I would have been rock hard playing with that stuff. I did alot of old convection stuff 30 years ago in Atlanta. Huge ductwork on what used to be coal burning that was converted to oil then converted to gas. And they still work fine. No blower at all. Stand on a vent and it would blow your hair around.
@RoaddogRoaddog
@RoaddogRoaddog 7 месяцев назад
Man, great job. Bro I swear that’s the same song when shit hits the fan while I’m working, had me worried as hell with that water lol
@BuilderJay
@BuilderJay 7 месяцев назад
wow, LOVE this video. Thanks for doing this.. I am always looking forward fo your vidoes! How many BTU was that boiler?
@compactc9
@compactc9 7 месяцев назад
Cracked me up, I had a gut feeling that HUGE wrench would be absolutely necessary, just had a feeling...
@PawsumGaming
@PawsumGaming 7 месяцев назад
I wouldn't blame you at all for using all aluminum pipe wrenches.. they are a lot of weight to carry around... the less weight I carry the better. Looked like a T4 stat on the wall too..
@stopthetyrants2851
@stopthetyrants2851 7 месяцев назад
Your a great inspiration for the young men. Would love to know what training you received or what school you went to
@BaconJD420
@BaconJD420 7 месяцев назад
A little trick on how to break a frozen Union take two hammers, one of them being 3 pound, the other being equal or next biggest size do you have, push the 3 pound hammer on one side of the nut and hit it with the other hammer on the other side of the nut (180 degrees) use the big hammer to “back it up” They will usually break free after a good whack or two, keep up the good work young man
@sandy1653
@sandy1653 7 месяцев назад
It's interesting to see these kinds of heating systems, because we just don't have 'em down here in FL. Hell, my house doesn't even have heat in it full stop jut because (normally) we don't need it.
@edjovi3677
@edjovi3677 7 месяцев назад
Wow that was an old unit lol hello from eddie leak master plumbing in ct great volg
@vasiltop
@vasiltop 7 месяцев назад
Hello friend. Greetings from Bulgaria. I'll give you a tip when you can't unscrew an old cast iron pipe, take a hammer and hit it hard. Tried and tested.
@TheKnifed
@TheKnifed 7 месяцев назад
That residential gas valve, looks strikingly similar to the Honeywell gas valves used on commercial fryers made by frymaster.
@sullysullivan1282
@sullysullivan1282 7 месяцев назад
This is giving me flashbacks to 1. figuring out what the f our LWCO was doing and 2. the one time our blower contactor got stuck in and I was losing my mind trying to figure out what the hell was going on
@guygfm4243
@guygfm4243 6 месяцев назад
I don’t know how they afford to run the boiler, non condescending boiler wow. Love the videos
@29nathanjones.
@29nathanjones. 6 месяцев назад
love the content u make where are u located at state wise bro
@Ali.A72
@Ali.A72 7 месяцев назад
Does that boiler use 2 gas valves in series for some reason?
@Djkyle65
@Djkyle65 7 месяцев назад
Man im impressed with your shop how in the world do you keep up with inventory?
@chrisconway4218
@chrisconway4218 7 месяцев назад
Hey man. Wanted to tell you that you have rapidly become one of my favorite content creators here. Wish you were a few hours further north. Would love to have you on our team( except for your van, that interior makes me cringe lol)...
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
thank you your generous comments Chris! i hate my van lol, just been running around a lot right now (our busy season) seems like just as im finishing a job i get a "not and emergency but i need you to go there right away and look at it" call so i just throw everything in and run, something i have to get better at and work on haha
@AmericanFarmerHVAC2024
@AmericanFarmerHVAC2024 7 месяцев назад
I like the mansion you chose for the video thumbnail. I assume you know where it came from?
@OneSaintPaul
@OneSaintPaul 7 месяцев назад
THE GUNS! WE DIG IT!!!
@pinkiuspius
@pinkiuspius 6 месяцев назад
Oooh boom boilers. Screw up and theres goes a city block.
@compactc9
@compactc9 7 месяцев назад
Some other guy on youtube ran into a house with this type of heating setup. That one was a hot water system instead of steam though.
@NobleOsprey
@NobleOsprey 6 месяцев назад
If you want them to keep that system give them an offer than can't turn down on a service agreement of some kind
@oilandfireguy1739
@oilandfireguy1739 7 месяцев назад
Im wondering how many btus that is? I only work with oil and we have some large residential accounts. But i think the most ive seen is 2 boiler at 1.5 gph.
@kevin7151
@kevin7151 7 месяцев назад
Good video. Amazing how things were built years back. More amazing is that you actually have the knowledge and skills to work on that system. Wishing you a very Merry Christmas.
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
You as well brother thank you, I can only work on a heating system like this because between my two bosses, they have a combined 80 years of experience
@pdzh
@pdzh 6 месяцев назад
Do you check for gas regulator manufacture/expiration dates? I mean, they not not going to work properly forever.
@Wolfhound.
@Wolfhound. 7 месяцев назад
so was anything done about the water situation im guessing that is what took out the boiler in the first place
@DJSephEntertainment
@DJSephEntertainment 7 месяцев назад
Can you explain why you hold back with the big wrench and not the smaller one?
@grounded-b937
@grounded-b937 7 месяцев назад
you always use a bigger wrench to hold the back the fitting or pipe.
@syntaxis5584
@syntaxis5584 6 месяцев назад
10:52 you know you can take the handle off and turn it the other way right?
@rayarsenault1958
@rayarsenault1958 7 месяцев назад
6:55 better to be looking at it, than looking for it...
@jakub3851
@jakub3851 6 месяцев назад
Never seen one
@Keegeth
@Keegeth 7 месяцев назад
Why do u need 2 gas valves?
@bestfriendhank1424
@bestfriendhank1424 7 месяцев назад
No need to worry about running the boiler to warm up the basement. I think you are hot enough.
@user-rf4ps5co8r
@user-rf4ps5co8r 7 месяцев назад
It’s a two pipe steam trap
@zackmi2
@zackmi2 7 месяцев назад
repeated what i was thinking in my head 'they seriously look like boiler sections" lol
@aaronbrandenburg2441
@aaronbrandenburg2441 6 месяцев назад
Have seen something similar long ago. However I've seen the biggest steam radiator I've ever seen had got to be the one that was underneath the Oregon Loft at a church! That thing must have been at least more than 8 ft wide and about 4 ft deep or more big rectangular thing Also in the organ Chambers the radiators were actually essentially Loops of steam pipe can't remember defending Arrangements but they may have been the return fittings or u bend fittings. Not sure can't remember didn't get a good view of them often times either. You could tell that the place the boiler was fired recently by coal. Where things were relatively untouched you'd see that film over everything of the cold sweat over all the years. Also has anyone ever seen that affect that sometimes you see an old buildings where you can see the outlines of the plaster wooden laugh and I still don't know why this is and what causes this what oftentimes does occur when a place was heated by coal or other solid fuels. Still remember on the grandparents Farm years ago one morning woke up and realized there was smoke coming out of the heating vints! I did not know about this but they said that this would happen if the chimney flue had not been preheated enough to get a good draft and that's the only time this would happen what's a little concerned until I realized that this was to happen in that circumstance. They used to use corn cobs to get things going as kindling.
@don1857
@don1857 7 месяцев назад
Looks like they haven't done a blow-down for many years!
@grandinosour
@grandinosour 7 месяцев назад
I would say if that building is going to be renovated that the steam boiler should be replaced.
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
Definitely will be
@waltdembeck4634
@waltdembeck4634 7 месяцев назад
I don't know dude, your pretty good! Mickey Pipes better be careful!
@theunit5939
@theunit5939 7 месяцев назад
The difference between the 2 90s is the steal one wont cracked when you hit it with a hammer the steam 90 will crack open if you hit it with a hammer.
@MrButuz
@MrButuz 6 месяцев назад
Man it’s such a shame that old stuff will end up being ripped out. That boiler looks like it’s been under water a lot.
@KevinKinder-ey9gv
@KevinKinder-ey9gv 7 месяцев назад
Hate to pay that gas bill 💸
@markcollins457
@markcollins457 7 месяцев назад
Not cool seeing a McDonald Miller low water cut off "Disconnected " on a steam boiler.
@mikev.1034
@mikev.1034 7 месяцев назад
👍🤘🤙
@DominicEidson
@DominicEidson 6 месяцев назад
"metric shit-ton" vs. "shit-long-ton" or "shit-short-ton" ? Leave it to the US to have multiple tonnage measures.
@ThumperKJFK
@ThumperKJFK 7 месяцев назад
✌👍
@truckgotstuck
@truckgotstuck 7 месяцев назад
When you're de-rusting the burner tubes your nose and sinuses will thank you if you put on a mask, even if it's a cheap N95 mask. You might have noticed a weird irony taste in your mouth and your sinuses were feeling heavy and your nose was plugged later that day. The rust particles can get really rough on you. If you breathe in that rust dust too often it causes nose bleeds! I speak from experience.
@Slasinth
@Slasinth 6 месяцев назад
Great job, maybe wash your hands before you go through the client's house checking fixtures 👍
@craigforster9861
@craigforster9861 7 месяцев назад
My bet boiler return trap.
@ed6837
@ed6837 7 месяцев назад
Shouldn't use cast iron fittings on gas. I would be concerned with how the water got in the gas line.
@IvanBogdanovych
@IvanBogdanovych 7 месяцев назад
Hi, there. I'm new to your channel. I don't speak English very well. Can you turn on subtitles? It will help me to follow you.
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
Absolutely, I did not have time to add them this morning but I will add them
@IvanBogdanovych
@IvanBogdanovych 7 месяцев назад
Thank you very much @@theapprenticesurvivalguide
@grounded-b937
@grounded-b937 7 месяцев назад
I would have pulled the drip leg and emptied all the water out.
@frankvigilante3423
@frankvigilante3423 7 месяцев назад
You’re not allowed to use steam 90’s on that gas train.On a gas line you should be using malable steel fittings.A mechanic working on a gas line by himself should know to never use cast iron on a gas line,they are for steam and hot water heating.Sorry pal your boss should have an A journeyman teaching you that.
@dannykeane6565
@dannykeane6565 7 месяцев назад
how about a interview with your boss
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
Once I can afford the proper equipment to do it right I will!
@JamesBrown-db9pk
@JamesBrown-db9pk 7 месяцев назад
dont need them big wrenchs muscel it off
@christopherwalker8327
@christopherwalker8327 7 месяцев назад
seems like you know a lot of shit for a young guy, good job😁
@theapprenticesurvivalguide
@theapprenticesurvivalguide 7 месяцев назад
Always looking to learn more!
@786otto
@786otto 7 месяцев назад
If is not your house, hope you get paid.
@dand5593
@dand5593 7 месяцев назад
It is not steam anywhere there, only hot water.
@loramurray7954
@loramurray7954 7 месяцев назад
Get yourself a pipe stand!!
@danbrit9848
@danbrit9848 6 месяцев назад
thay didnt get rich by having bad choices ...thay keeping that heater i guarantee...its way cheaper per month garinteed
@z1teq
@z1teq 4 месяца назад
My god, please wear eye protection when using rotating wire brushes. THOSE WIRES ARE NOT FUN TO GET IN YOUR EYES!!!!!!!!!!!!
Далее
Boiler Room Disaster Escalates to Apartment Flood!
27:07
Commercial Steam Boiler Pump Rebuild
14:42
Просмотров 13 тыс.
Поём вместе с CLEXXD🥵 | WICSUR #shorts
01:00
Pilot Tries Dangerous & Illegal Approach!
13:21
Просмотров 112 тыс.
Why New York Is Powered By Steam - NYC Revealed
11:29
Просмотров 307 тыс.
I Went Mining For 12 Hours & Made $____?
56:34
Просмотров 1,6 млн
Off Grid Micro Hydro - Building a 6kW Off Grid EMPIRE
29:35
HVAC Nightmare: Units Crash Before Winter Storm
19:50
Dead Men's Steam School Seminar
3:17:20
Просмотров 24 тыс.
Разговор на Патриках
1:01
Просмотров 4,1 млн
Spot The Fake Animal For $10,000
0:40
Просмотров 165 млн
19 июля 2024 г.
0:20
Просмотров 9 млн