Ampac Fire Finder to Pertronics F220 - Fire Detection & Alarm System 

FIRE PROTECTION GUY
Подписаться 3,1 тыс.
Просмотров 1,1 тыс.
50% 1

Опубликовано:

 

22 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 22   
@JayTechTips
@JayTechTips 11 месяцев назад
The F220 is an amazing panel
@fireprotectionguy7943
@fireprotectionguy7943 11 месяцев назад
True
@Black_Kakari
@Black_Kakari 6 месяцев назад
Replacing an Amcrap. Best thing to do. Pertronics F220 is far better than the dirty 3030 by Honeywell and Amcrap
@fireprotectionguy7943
@fireprotectionguy7943 6 месяцев назад
Totally agree....
@SebastianC701
@SebastianC701 11 месяцев назад
From Aussie made to NZ made! 👍
@dutchwolf2675
@dutchwolf2675 11 месяцев назад
How come for replacement. Great video!
@fireprotectionguy7943
@fireprotectionguy7943 10 месяцев назад
The owner said so, I just suggested the replacement of the amplifier. Since the system is already discontinued...might as well replace the entire lot.
@bigcomputerman4482
@bigcomputerman4482 11 месяцев назад
What are the purpose of these ventilation fans? Why are they directly connected to the Fire Alarm panel?
@fireprotectionguy7943
@fireprotectionguy7943 11 месяцев назад
Ventilation fans are suppress the spread of fire or smoke. It can be press fan, stair press fans, exhaust fan or supply fans. Locating at the FIP, as per standard, the fire brigade can control those fans - switch off or on. Sample, the fire system is reset - no active alarm.. but there's still smoke or fumes in the carpark. They can run the exhaust from the fan controls at the FDCIE/FIP.
@bigcomputerman4482
@bigcomputerman4482 11 месяцев назад
@@fireprotectionguy7943 Thanks
@ruddigger83
@ruddigger83 4 месяца назад
@@fireprotectionguy7943 100% AS1668.1&2. Even without a FIP in the building, Fan controls are required now and prefered in the earlier version mounted at the entry. I like that you mentioned the Pump room ventilation. I have some buildings that are programmed not to run the fans during a trip. Even the matrix shows it this way. Crazy.....
@qujacky5134
@qujacky5134 11 месяцев назад
Hi Elmer, does pertronic f220 have function to change conventional system to addressable system,and how can you download from ampac program and convert them to pertronic program, thank you
@fireprotectionguy7943
@fireprotectionguy7943 10 месяцев назад
Changing conventional to addressable - Yes. There's a module for that. For the programming, download the Ampac configuration and start from stratch... They are different in programming.
@qujacky5134
@qujacky5134 10 месяцев назад
@@fireprotectionguy7943 thank you for your help
@wizofoz0605
@wizofoz0605 4 месяца назад
You went two days with no connection of the Sprinklers to Brigade!!??Wow, risky...
@fireprotectionguy7943
@fireprotectionguy7943 4 месяца назад
It was operating in the same day. The only input that is not working is the fans which I hooked up the next day.
@jackknight511
@jackknight511 9 месяцев назад
What’s the average wage of a fire alarm technician in Australia?
@fireprotectionguy7943
@fireprotectionguy7943 9 месяцев назад
Check this website. www.uman.com.au/
@niloyu105
@niloyu105 11 месяцев назад
Keep watching and support ❤❤❤ bukas na flight kopo Sir Elmer pabalik Saudi stay blessed and safe din po sa inyo 🙏❤️
@fireprotectionguy7943
@fireprotectionguy7943 11 месяцев назад
Hahaha dating ko naman sa Pinas sa Friday... Ingat
@niloyu105
@niloyu105 11 месяцев назад
Hindi pa talaga Sir natugma magkita tayo 🙏 😂
@fireprotectionguy7943
@fireprotectionguy7943 10 месяцев назад
@@niloyu105 Totoo yan
Далее
Ребенок по калькуляции 😂
00:32
Просмотров 162 тыс.
FIRE PUMP | FIRE PUMP TESTING |
24:18
Просмотров 756
Potter Training on Sprinkler System
10:34
Просмотров 20 тыс.
Monthly Fire Diesel Hydrant Pump Testing - Fire System
8:34