Тёмный

Anchor Bolt : What , Why and How 

Civil Engineer Tonmoy Maity
Подписаться 22 тыс.
Просмотров 73 тыс.
50% 1

Опубликовано:

 

13 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 39   
@rimmaaleksandrovsky4705
@rimmaaleksandrovsky4705 Год назад
such great tutorial, helped me with my assignment. Very clear and straight forward explanation.
@TonmoyMaity
@TonmoyMaity Год назад
Glad you like it
@pankajkumar-gv7pn
@pankajkumar-gv7pn 7 месяцев назад
Thank you so much for providing good information. Please make a video on topic how steel base plate transfer load on concrete pedestal. Most of the book cover directly base plate to concrete pedestal uniform load type. But in practical most of time I see steel base plate is elevated over pedestal through bolt even no any grouting has provided. Will it transfer load as point load through bolt on pedestal.
@TonmoyMaity
@TonmoyMaity 7 месяцев назад
Ok soon
@rakeshkansara8909
@rakeshkansara8909 Год назад
Explained very well. Thanks for video.
@TonmoyMaity
@TonmoyMaity Год назад
Glad you like it
@bheemappakshatrer4547
@bheemappakshatrer4547 2 года назад
Very nice explanation, sir could you explain us why we use lesser strength material for anchor bolts when compared to main structure bolts
@TonmoyMaity
@TonmoyMaity 2 года назад
It's very simple..in main structural bolt we consider yield and rupture but in anchor bolts we only consider ultimate strength. Isn't it ? And as ultimate strength is much higher than yield strength, even if we use lesser strength material our purpose is solved
@aqsaneaz7904
@aqsaneaz7904 Год назад
Excellent explanation
@sasikumartherayil9620
@sasikumartherayil9620 3 года назад
Sir Theory very clear now. Can you add a problem on anchor bolt
@TonmoyMaity
@TonmoyMaity 3 года назад
I will try
@arunsingh83
@arunsingh83 11 месяцев назад
Please provide how to calculate reinforement to avoid crack due to shear force & tension....
@sulemanmansoori6061
@sulemanmansoori6061 Год назад
Hello sir, I have a question if the base is pinned connected and the upper frame is moment connected how does the flange carry loads from column to the base plate and to the foundation …. Your explanation on this would be very helpful
@TonmoyMaity
@TonmoyMaity Год назад
This needs a video explanation. I will put it as soon as possible.
@aloknayak1754
@aloknayak1754 2 года назад
Your approch is very good
@TonmoyMaity
@TonmoyMaity 2 года назад
Thank you 💗
@ForensicCats
@ForensicCats 2 года назад
11:50 it is tension in the bolt but it is because of "compression" that the crack developed... The bolt "head" is similar to a compressive load, this developed the "cone failure"... This anchor failure is because of concrete compression failure from the point loading of the bolt head (using tension as the loading force)... Hope that makes sense... A deeper embedded head would resist more and a larger head /"plate" would distribute the load also. Overlapping cones of course are always an issue and wind loads create a shock force greater than non-shock loads. Deeper concrete footers and embedding of bars are superior to the smaller surface bolts. Your fracture implied surface tension was not shared in the concrete resistance... Loading was from bolt head and this cone failure is typical (38-45 degrees )... Typical of the fractures from the edge of the bolt head "edges" and of course this would be circular from top view / visual. The question is, how much force to create this fracture in this concrete and embedment? Again, this is an an internal compression load from the bolt head and I can get results from drilling a hole in a core and loading head of bolt to duplicate this failure (of course I would drill a hole to point load the embedded head , this will allow for the surrounding concrete to preticapate to some degree. My theory is of "stirrups" and this allows for "trapping" exploding concrete, this is not a deflection failure but an "bursting failure" and strapping does a great job on trapping that buckling failure. Confine the cone, do not allow it to "displace"... I hope I did not confuse you and I hope you do take offense.
@kenp3L
@kenp3L 2 года назад
“A deeper embedded head would resist more and a larger head /"plate" would distribute the load also.” Agreed. It would have cost very little to increase the embedded bolt length to, say, 20 times the major diameter. Also, the embedded washer (if we can call it that) is too small in diameter and curiously over-thick. Better would have been a diameter of 2.5 to 3.0 times the major diameter of the threaded rod. But notice, though, on the low-resolution photo what appears to be a plastic sheath over the embedded portion of the threaded rod above the “washer.” This is smart. It prevented concrete from bonding to the rod above the washer. Two factors to consider. One, concrete is strong in compression, but weak in tension. Two, the rod, like any elastic object, will elongate as load is applied. If the concrete had bonded to the upper part of the rod (which, as I stated, was not the case), as the rod elongated under tension, part of the tensile load would have been shared by the concrete bonded to it. Since concrete is weak in tension, a local concrete failure would have occurred near the surface with a proportionally smaller cone of failure compared to that shown in the photo. The immediate result would have been less remaining intact material to support the tensile load. One can imagine a cascading effect, especially under cyclical loading, where supporting material would be progressively lost until ultimate failure. The load required for said hypothetical failure, we may reasonably speculate, would be significantly less than was the case of the failure shown in the photo, where concrete bonding above the washer was prevented. Your thoughts?
@jn9607
@jn9607 3 года назад
Plz tell about double connection in column in next video bro
@TonmoyMaity
@TonmoyMaity 3 года назад
Ok
@tris2870
@tris2870 Год назад
how about value of torque anchorbolt. how to calculate?
@ssaranya5524
@ssaranya5524 Год назад
Thanks for the video. When modelling anchor bolts in ABAQUS, is it necessary to include bolt pretension?
@TonmoyMaity
@TonmoyMaity Год назад
You can if your code allows
@vaishnavikitey1711
@vaishnavikitey1711 3 года назад
Very nice
@TonmoyMaity
@TonmoyMaity 3 года назад
Thank you for your appreciation.
@singhbrajesh89
@singhbrajesh89 3 года назад
Excellent Dear Maity
@TonmoyMaity
@TonmoyMaity 3 года назад
Glad you like it
@ashwaniverma2137
@ashwaniverma2137 2 года назад
Why is sometimes Base plate kept on nuts and later grouting is done below base plate . Why base is not kept directly over Concrete surface.?
@TonmoyMaity
@TonmoyMaity 2 года назад
To ensure uniform surface contact
@Szhihihihihihi
@Szhihihihihihi Год назад
Keep it up !
@TonmoyMaity
@TonmoyMaity Год назад
Always!
@aqsaneaz7904
@aqsaneaz7904 Год назад
Hats off
@TonmoyMaity
@TonmoyMaity Год назад
Glad you like it
@brucetrappleton6984
@brucetrappleton6984 Год назад
The bolt will never be stronger than the concrete. Before the concrete cracks, the bolt will crack first
@TonmoyMaity
@TonmoyMaity Год назад
yes right 50 mpa vs 415 mpa
@lipubhaipatna
@lipubhaipatna 8 месяцев назад
Are bhai Hindi boll
@TonmoyMaity
@TonmoyMaity 7 месяцев назад
don't be selfish...it's for everyone..not only for Hindi medium students
@PBS-nm1uu
@PBS-nm1uu 2 года назад
i missed your point
Далее
А я с первого раза прошла (2024)
01:00
Failure of concrete anchors explained
7:04
Просмотров 733 тыс.
Why Buildings Need Foundations
14:51
Просмотров 3,5 млн
Installation of L Bolt
10:21
Просмотров 72 тыс.
What's the Difference Between Paint and Coatings?
14:23
H.D. Bolt / Anchor Bolts Installation in Simple Steps
39:58
А я с первого раза прошла (2024)