Antipumping Relay in English 

Real Life Indrajit Pal
Подписаться 12 тыс.
Просмотров 14 тыс.
50% 1

Most Important for Electrical Engineer

Опубликовано:

 

27 дек 2019

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 24   
@rajeshtk1246
@rajeshtk1246 4 года назад
You should have added a 52a contact in series with the 94 coil along with a NO contact of the 94 (in parallel with the 52a) itself for the full functioning of the Anti Pumping logic. (52a contact will ensure that the AP contactor will be picked up only after the CB successfully closes. 94's NO will ensure that the AP logic will still be in effect if the CB is closed on to a fault.)
@user-wm5ti1od6r
@user-wm5ti1od6r 3 месяца назад
Superb
@surendrakverma555
@surendrakverma555 2 года назад
Very good 🙏🙏🙏🙏🙏
@Electricalknowledge-gs5ip
@Electricalknowledge-gs5ip 11 месяцев назад
Nice explanation sir
@reallifeindrajitpal
@reallifeindrajitpal 11 месяцев назад
Keep watching
@Vigneshvicky-sn1qy
@Vigneshvicky-sn1qy 3 года назад
Thank you sir
@AdityaSingh-jz8te
@AdityaSingh-jz8te 4 года назад
Sir please provide a video on Trip circuit & Closing circuit also & if you can teach in hindi than we will learn content more effectively
@reallifeindrajitpal
@reallifeindrajitpal 4 года назад
Pleased search I have already uploaded circuit breaker control ckt.
@panditvishal5451
@panditvishal5451 4 года назад
normal time antipumping coil is energise condition so its nc contact has opened condition continuously so how closing command gets?
@dbengineers5605
@dbengineers5605 4 года назад
Thankyou so much for this, please keep it up.
@ManojKumar-gm7fb
@ManojKumar-gm7fb 3 года назад
Inter lock means
@eakubhosen2339
@eakubhosen2339 3 года назад
Thank you for this video sir
@reallifeindrajitpal
@reallifeindrajitpal 3 года назад
Thanks 👍
@sauravmazumdar5369
@sauravmazumdar5369 3 года назад
Nice...
@reallifeindrajitpal
@reallifeindrajitpal 3 года назад
Thanks 👍😊
@d.kkumar4186
@d.kkumar4186 4 года назад
Nice video sir
@reallifeindrajitpal
@reallifeindrajitpal 3 года назад
Thanks for watching ,please subscribe my channel and share
@dineshtusia968
@dineshtusia968 3 года назад
Sir Apki video kaafi Jyaada motivation hoti h, lekin muje ye Hindi language m smjhna chaata hu. Can you translate the explanation of video in Hindi if you don't mind. Plzzz do appropriate help me I P Sir.
@reallifeindrajitpal
@reallifeindrajitpal 3 года назад
My hindi is not good
@ranjan1436
@ranjan1436 4 года назад
when the command is sent through TNC switch to the breaker closing coil at the same time AP relay is also energised from the same source, its NC will change to NO position the breaker will immediately trip..May be u missed the link?
@rjshtk
@rjshtk 4 года назад
You are wrong. It will never trip the CB while Close command is given via TNC switch (Ofcourse only if it's not closed onto fault). You might want to read up on the function of NC contact of 94 in the close path..
@pradiptarout8405
@pradiptarout8405 4 года назад
Thank you sir
@nanjundaswamy3468
@nanjundaswamy3468 3 года назад
Thank you very much sir
@reallifeindrajitpal
@reallifeindrajitpal 3 года назад
Thanks ,please subscribe my channel
Далее
🔴Ютуб закрывают... Пока?
00:39
Просмотров 1,8 млн
Circuit breaker control and supervision in English
13:28
86 Relay , Master Trip Relay.
8:55
Просмотров 25 тыс.
why we use slope in differential relay
13:14