@peterjenkins886
@peterjenkins886 7 месяцев назад
can you guys do a video on common faults and a troubleshooting guide for common failure points or operator setup mistakes
@appliedadhesives2683
@appliedadhesives2683 6 месяцев назад
Absolutely! We'll make sure to contact you when we have something up.
@peterjenkins886
@peterjenkins886 7 месяцев назад
thank u guys
@tshepangsebiloane7470
@tshepangsebiloane7470 Год назад
Let's talk about the inputs and outputs, where do i activate them so that they show on the operator screen? I have applied inputs via terminal 8 and 9 , 10 and 11 and my three outputs as it is in the manual, now where do i activate them?
@appliedadhesives2683
@appliedadhesives2683 Год назад
To start off this can only be done on input #1. Input #1 is on pins 8 & 9. So you wire up either a plc output (parent machine) or the 24Vdc applicator activation signal to pins 8 & 9. This completes the electrical hookup. Power on the unit. Select operating parameters and go to location 30. Set parameter 30 to 10. Now go to parameter 24. Set this to the number of minutes you want to wait before the unit go’s into Stand-bye. Note to test but it at 1, side note I believe there is a 4 or 5 minutes default delay. So it may take 5 or 6 minutes to drop into stand-bye. If you have any further questions feel free to reach out to us at (833) 293-7278 or on our website www.appliedadhesives.com.
@bruceaustreng7535
@bruceaustreng7535 Год назад
The green ✅ is not lighting up, so the machine will not start, what are some things I can do to get it started
@appliedadhesives2683
@appliedadhesives2683 Год назад
Here is a list of reasons why the green check mark will not light. - Not up to set-point temperature on all zones. Call me - possible bad heating zone. - parameter # 4 has a long delay Programer (5 minutes is enough for a pneumatic pump. Ten minutes for a gear pump. - The green check-mark is flashing indicates that the parent machine his preventing this from staying on. One of the inputs is set to inhibit the pump from activating. Parameters 30 to 39. If you have any further questions feel free to reach out to us at (833) 293-7278 or on our website www.appliedadhesives.com.
@wcioden
@wcioden Год назад
How to change temperature from degF to degC?
@appliedadhesives2683
@appliedadhesives2683 Год назад
Parameter 20 will allow you to change from F to C.
@opunake4lyf
@opunake4lyf Год назад
How do I install an external light to signal low glue level, I have changed parameters 40 to 4 but I don't get a signal out
@appliedadhesives2683
@appliedadhesives2683 Год назад
Low level signal is a closed contact. They supply the signal. See manual - chapter 3 (the last 6 to 8 pages).
@ttv_slammer_bot0175
@ttv_slammer_bot0175 Год назад
What the hottest you recommend me put the degrees f
@appliedadhesives2683
@appliedadhesives2683 Год назад
This is a bit more nuanced. You can go up to 450°F. The common prongs are boron with a max temp of 390°F. To go higher you need Kalrez seals.
@radzio132
@radzio132 Год назад
How can i change temperature in standby mode?
@appliedadhesives2683
@appliedadhesives2683 Год назад
Standby - this is found in operating parameters. Default is 100F and this represents how much temperature is lowered from the operating setpoint. The parameter # is 23. The manual for Pro Blue & Dura Blue, at the end of chapter 3. This section goes through it. Lock out Tag out!! Safety first. First off the manual switch destinations and you may overlook something because of it. I’ll outline how to setup automatic Standby. To start off this can only be done on input #1. Input #1 is on pins 8 & 9. So you wire up either a plc output (parent machine) or the 24Vdc applicator activation signal to pins 8 & 9. This completes the electrical hookup. Power on the unit. Select operating parameters and go to location 30. Set parameter 30 to 10. Now go to parameter 24. Set this to the number of minutes you want to wait before the unit go’s into Stand-bye. Note to test but it at 1, side note I believe there is a 4 or 5 minutes default delay. So it may take 5 or 6 minutes to drop into stand-by. If you have any further questions feel free to reach out to us at (833) 293-7278 or on our website www.appliedadhesives.com.
Далее
How to set up 7 Day clock on Nordson Pro Blue
3:58
Просмотров 13 тыс.
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Просмотров 1,1 млн
How High-Quality Exhaust Fans are Made
16:46
Просмотров 5 млн
All About Renia Colle de Cologne
18:16
Просмотров 1,5 тыс.
Nordson DuraBlue Hot Melt Adhesive Gluing Systems
4:54
APPLIED How to Set a Passcode on a  Nordson® ProBlue®
3:23
DuraBlue 4L Hot Melt Machine
3:55
Просмотров 29 тыс.
Purging a Nordson ProBlue 15
3:58
Просмотров 1,5 тыс.
robatec glueing parameters
2:21
Просмотров 1 тыс.